Fatma Güneş

Dr. Fatma Güneş


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ADAybike Düzgün
Aybike Düzgün
FGFatma Güneş
Fatma Güneş
MKMustafa Kocacıklı
Mustafa Kocacıklı
ÖYÖmer Suat Yaluğ
Ömer Suat Yaluğ

25 December 2023 in Selcuk Dental Journal
Verified
Journal Article
Closed access
FGFatma Güneş
Fatma Güneş
MKMustafa Kocacikli
Mustafa Kocacikli
TKTuran Korkmaz
Turan Korkmaz
Günümüz diş hekimliğinde estetik restorasyonlara sürekli artan ilgiyle doğal diş yapısına benzer, biyouyumlu, iyi mekanik ve fiziksel özelliklere sahip metal içermeyen restorasyonlar daha sıklıkla tercih edilmektedir. Bu materyallerden biri olan termoplastik polimer yapısındaki Polietereterketon (PEEK) diş hekimliğinde kullanımı hızla yaygınlaşmaya başlamıştır. PEEK, keton ve eter fonksiyonel grupları ile birbirine bağlı aromatik halka ve amorf-kristal fazdan oluşan iki fazlı doğrusal zincir yapısına sahip, 1.3-1.5 g/cm3 yoğunlukta yarı kristalli termoplastik bir homopolimerdir. PEEK materyalinin biyouyumlu olması, elastik modülünün kemiğe daha yakın olması, şok absorpsiyonu, korozyona uğramaması, yüksek aşınma ve kırılma direncine sahip olması, üstün cilalanabilir özelliği ile plak tutulumun düşük olması ve metal restorasyonlara göre daha hafif bir materyal olması gibi özelliklere sahiptir. PEEK materyali, termal özellikleri nedeniyle insan vücudunda stabil kalmaktadır. Yüksek ısıya karşı dirençlidir ve birçok sterilizasyon yöntemine uygundur. Kimyasal olarak inert bir materyaldir. Bu sebeple diğer materyallere düşük reaksiyon gösterir ve birçok geleneksel çözeltide çözünmemektedir. PEEK materyaline karşı alerjik reaksiyon gelişme oranı düşüktür. Bu nedenle metal alerjisine sahip hastalar için iyi bir alternatiftir. Bu materyal diş hekimliğinde; implant materyali, implant abutment materyali, implant üstü dijital ölçü postu olarak, implant destekli overdenture protezlerde hassas bağlantı parçası olarak, implant üstü hibrit protezlerde alt yapı materyali, iyileşme başlığı materyali, sabit protezlerde alt yapı materyali, geçici kron materyali, hareketli protezlerde ana bağlayıcı ve kroşe materyali, okluzal splint materyali olarak kullanılabilmektedir. Anahtar Kelimeler: Diş İmplantları, Diş Protezi, Polietereterketon

26 September 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FGFatma Güneş
Fatma Güneş
TKTurhan Korkmaz
Turhan Korkmaz
Additive manufacturing of thermoplastic polymers via fused filament fabrication (FFF) is gaining popularity because of its time and cost efficiency. Semicrystalline polyetheretherketone (PEEK) requires extensive postprocessing, whereas amorphous polyphenylene sulfone (PPSU) offers greater predictability and reliability. The purpose of this study was to compare the mechanical properties of PPSU, which is a new material for dental applications, and PEEK to evaluate the effects of different manufacturing methods on the mechanical properties of these materials. This study used a PEEK disc (Juvora Dental Disc, Juvora, UK) for subtractive CAD-CAM method-fabricated samples (PEEK-CG), a pure PEEK filament (Vestakeep i4 3DF filament, Evonik Industries AG, Germany) for FFF-fabricated samples (PEEK-3D), a pure PPSU filament (FIL-A GEHR, Gehr Plastics Inc., Germany) for FFF-fabricated PPSU samples (PPSU-3D), and a bulk PPSU material (Radel R-5000 NT, Solvay, France) for injection-molded samples (PPSU-INJ). A total of 80 samples (n = 20 per group) were tested. Half were evaluated for three-point bending (n = 10 per material), and the rest were evaluated for Vickers hardness (n = 10 per material). The Kruskal‒Wallis H test was used for between-group comparisons, and the Mann‒Whitney U test was used for pairwise comparisons (α = 0.05). PEEK-CG, with a flexural strength of 299.69 ± 12.26 MPa, a Young’s modulus of 8.92 ± 0.28 GPa, a flexural stress at 3.5% strain of 6.97 ± 0.65 MPa, and a Vickers hardness of 40.02 ± 10.38 kg/mm², significantly outperformed PEEK-3D (P < 0.05). PPSU-INJ outperformed PPSU-3D in all tests, with significant differences only in Young’s modulus (P = 0.013), with other differences not significant (P > 0.05). PEEK-3D outperformed PPSU-3D with a flexural strength of 220.75 ± 12.07 MPa, a Young’s modulus of 7.05 ± 0.94 GPa, a flexural stress at 3.5% strain of 3.94 ± 0.42 MPa, and a Vickers hardness of 21.48 ± 2.69 kg/mm² (P < 0.05). PPSU, with mechanical properties analogous to those of PEEK, meets the standards established for use in dental applications. These applications include its use as a fixed denture infrastructure, implant material, and removable denture clasps. The mechanical properties of 3D-printed PEEK and PPSU were found to be inferior to those of other methods, highlighting the need for improved additive manufacturing parameters.

20 July 2026 in International Journal of Applied Ceramic Technology
Verified
Journal Article
Closed access
PDF file
HBHalil Bakıç
Halil Bakıç
FGFatma Güneş
Fatma Güneş
TKTuran Korkmaz
Turan Korkmaz

30 December 2025 in Journal of International Dental Sciences
Verified
Journal Article
Closed access
FGFatma Güneş
Fatma Güneş
Hybrid prostheses, which are among the implant-supported fixed prostheses, are defined as screw-retained restorations produced from different materials. These prostheses reconstruct the dental hard tissues together with the lost gums and surrounding tissues. Hybrid prostheses can be prepared from metal substructures produced from chromium-cobalt (Co-Cr) alloy, millable zirconia and polyetheretherketone (PEEK). Co-Cr metal substructures can be obtained by traditional casting, selective laser sintering and computer-aided manufacturing/computer-aided design (CAD/CAM) methods. Substructures such as zirconia and PEEK are generally produced with CAD/CAM. Substructures produced with the CAD/CAM method have advantages such as high precision adaptation to supports, slightly longer cantilever length, elimination of errors that may occur due to the technician, and elimination of the risk of shrinkage in the metal during casting. In hybrid prostheses, various materials such as metal ceramics, all-ceramic materials, acrylic resins, and thermoplastic polymer PEEK are used for the superstructure production. Dental ceramics to be used as the superstructure can be traditional feldspathic or can be obtained from all-ceramic systems such as monolithic zirconia produced by CAD/CAM method. With the developments in material structure, monolithic zirconium hybrid prostheses cemented to titanium bars produced by CAD/CAM method have begun to be produced. The computerized workflow of this digitalized production process provides reproducible results and excellent adaptation and passive placement of the bars. This literature review aims to provide an up-to-date overview of the materials used in hybrid prosthesis production and to evaluate the clinical benefits and limitations of these materials and techniques.

22 August 2025 in Selcuk Dental Journal
Verified
Journal Article
Open access
PDF file
FGFatma Güneş
Fatma Güneş
MÖMerve Öge
Merve Öge
MKMustafa Kocacıklı
Mustafa Kocacıklı
HBHaluk Bodur
Haluk Bodur
Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disease characterized by palmoplantar keratosis and early-onset severe periodontitis. This disease affects both primary and permanent teeth, causing premature tooth loss. Various etiological factors are associated with PLS, including genetic mutations, immunological changes, and bacterial effects. The genetic defect associated with PLS has been shown to result from a mutation in the Cathepsin C gene, located on the long arm of chromosome 11 (11q14). Removable prostheses allow changes during the growth and development of the jaw bones in PLS patients, providing the function and aesthetics that are lost until the jaw development is complete. These case reports include two siblings (7-year-old boy and 11-year-old girl) with PLS and their prosthetic rehabilitation with partial removable prostheses with a multidisciplinary approach. Routine check-ups of the patients every three months have been continuing for approximately 6 months.