Hydrogen-powered fuel cells are the preferred energy source for electric aircraft. However, for aircraft applications, it is of upmost importance to reduce the mass of the fuel cell system. A considerable amount of the total system mass is due to the fuel cell cooling system. In this paper, the analysis of a 2 MW cooling system for fuel cell-powered aircraft is discussed. A detailed comparison is made between a conventional liquid cooling system with ethylene glycol–water (EGW) and a novel two-phase cooling system that uses the evaporation of a liquid to remove waste heat from the fuel cells. For this novel two-phase cooling system, several refrigerants were analyzed, and methanol resulted in the lowest system mass. The mass of a liquid EGW system is 35% higher than for two-phase methanol with accumulator and 2.4 times higher than for two-phase methanol without accumulator. Because of this large mass benefit, a demonstrator for a two-phase methanol cooling system without accumulator with a capacity of 200 kW is currently being built.
This paper explores the pumping characteristics and behaviour of a thermally driven self-oscillating pump. The pump consists of a single wickless capillary tube with a circular cross-section. The tube is closed at one end and has a T-section with two check valves at the other end to provide for a one directional flow. An experimental setup was built to investigate the output mass flow and pressure head of the pump. During the experiments, the performance of the check valves had a negative influence on the output mass flow. To determine this influence, a video analysis of the fluid oscillation without the check valves was conducted and compared to results with check valves. The average output mass flow with valves was approximately 0.0010. kg/s with a maximum measured pump flow of 0.0013. kg/s. The maximum pressure head delivered was 0.25. bar. A numerical model of the vapour bubble oscillation was developed to get a better understanding of the pump and its working principles. The model is based on the conservation of mass, momentum and energy, and resulted in a non-linear system of coupled differential equations. Overall, the experiments conducted with the thermally driven self-oscillating pump have shown that the pump has good potential to be used in aerospace applications
In the EU-funded BRAVA project, technologies for a fuel cell-based power generation system for aviation are being developed. In this paper, the test results for a demonstrator of a novel two-phase pumped cooling system with 20 kW cooling capacity are presented. This system uses the evaporation of a liquid to remove waste heat from the heat sources. Several concepts have been tested with this demonstrator, including the ‘no accumulator’ concept, which offers a large mass reduction compared to conventional cooling systems. Additionally, the system can be rotated, and the influence of the orientation has been tested.
In the EU funded BRAVA project, technologies for a Fuel Cell based Power Generation System for aviation are being developed. In this paper, the test results for a demonstrator for a novel two-phase pumped cooling system with 20 kW cooling capacity are presented. This system uses the evaporation of a liquid to remove waste heat from the heat sources. Several concepts have been tested with this demonstrator, including the ‘no accumulator’ concept, which offers a large mass reduction compared to conventional cooling systems. Also, the system can be rotated, and the influence of the orientation has been tested.
In the EU funded BRAVA project, technologies for a Fuel Cell based Power Generation System for aviation are being developed. In this paper, the analysis of a 2 MW cooling system is dis-cussed. A comparison is made between a conventional liquid cooling system with Ethylene Glycol Water (EGW) and a novel two-phase cooling system, which uses the evaporation of a liq-uid to remove waste heat from the fuel cells. The mass of a liquid EGW system is 35% higher than for two-phase methanol with accumulator and 2.4 times higher than for two-phase metha-nol without accumulator.