Ensuring the safety of rail networks requires precise detection of a train’s position on a track section. This is achieved using a “track circuit” system, in which the wheel–rail electrical contact is the key to maintaining the system’s reliability. However, any degradation of this contact can lead to a track circuit malfunction known as “deshunting”, creating a serious safety risk for the rail network and for passengers. This paper presents a refined approach to this concern by implementing a laboratory-scale test bench. The main objective is to reproduce the wheel–rail electrical contact under controlled conditions to better understand the various aspects of this contact. The criteria governing the dimensioning of the test bench at reduced scale are based primarily on mechanical considerations. In this study, a series of tests were carried out to investigate the behavior of the electrical resistance as a function of various parameters such as load, current and time. An original homemade salt spray system was designed and used for obtaining controlled rail oxidation. Our preliminary results highlight the impact of these factors on the electrical resistance, providing valuable insights for future advances in rail safety technology.
A widely used technique for locating the position of a train during its journey involves electrical detection: on a section of track, the train closes (“shunts”) a circuit dedicated to its location via its wheels and axles. The quality of the wheel–rail contact is therefore particularly important for signalling management and traffic control. In this paper, we show that the current flowing through the track circuit induces a permanent modification and a nonlinear, frequency-dependent behaviour of the electrical contact. We propose an analytical expression that describes the evolution of the measured voltage as a function of current and frequency for these nonlinear behaviours. This behavioural law was obtained using experimental measurements on a real train and could therefore be integrated into a global model describing the track system.
To manage and ensure the safety of traffic on rail networks, trains need to be reliably located at all times. This is achieved in many countries by electrically detecting their presence using so-called “track circuits” installed at regular intervals on each track, designed to detect when the wheels and axles of a train are shunting the two rails and to act accordingly on the signaling system. Such a detection principle is highly dependent on the quality of the electrical contacts between rails and wheels; the occurrence of high wheel–rail contact resistances can induce malfunctions known as “deshunting”, when the system is unable to judge the presence or absence of a train on a section of track. This type of potentially risky event must obviously be avoided at all costs. In this article, we focus on wheel–rail contact degradation resulting from steel oxidation, using a home-made, scaled-down test bench that reproduces real contact in the laboratory under controlled conditions. Given the complexity of the topic, the investigations are focused on static contact characterizations involving different degrees of rail oxidation and slow, stepwise variations in DC intensity.
With the increase in DC voltage levels in aircraft electrical networks up to 540 VDC, it is essential to improve the understanding and characterization of fault arcs. This article focuses on the characterization of opening electric arcs in air, between 100 and 1000 hPa, through static electrical quantities, namely the electric field and anode and cathode voltage falls. These quantities are determined from measurements of the arc voltage as a function of the inter-electrode distance, which is assumed to be equal to the arc length for arcs shorter than 10 mm. The experiments are performed with copper electrodes, under a 540 VDC power supply and currents of about 50 A. Two regions are identified in the voltage signals: a first region at short inter-electrode distances, typically below 1 mm, and a second region at larger distances. In the first region, no clear pressure-dependent trend is observed, whereas a distinct evolution with pressure is identified in the second region. A multi-camera setup provides complementary views of the arc structure and of the copper vapor distribution, which also appears to vary with pressure.
The safe management of traffic on rail networks requires that trains can be reliably located at all times. In many countries, this is achieved by electrically identifying their presence using ‘track circuits’ at regular intervals along each track: these devices detect when the wheels and axles of a train short-circuit the two rails (they are said to ‘shunt’ them) and the information is passed on to the signaling system. The quality of the electrical contacts between the rails and the wheels obviously plays a decisive role in the correct operation of this detection principle. The occurrence of high wheel–rail contact resistances can lead to malfunctions, known as ‘deshunting’, in which the system is unable for a certain period of time to conclude whether a train is present or absent on a section of track. This type of potentially risky event must obviously be avoided at all costs. In this article, we present the second part of a study devoted to the degradation of the wheel–rail contact resulting from steel oxidation, using a scaled-down home-made test bench that reproduces the real contact in the laboratory under controlled conditions. Following on from the first part, which dealt with the static characterization of the contact studied in the direct current, we are now tackling its dynamic characterization (rolling contact) under AC electrical conditions close to those of a track circuit. These new investigations again involve different degrees of rail oxidation, and analyze the influence of parameters such as contact force, speed, and current intensity.