Litai Ma

Litai Ma


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


3 January 2024 in Frontiers in Physiology
Verified
Journal Article
Open access
JXJun Xie
Jun Xie
YYYi Yang
Yi Yang
ZJZekun Jiang
Zekun Jiang
KZKerui Zhang
Kerui Zhang
XZXiang Zhang
Xiang Zhang
LMLitai Ma
Litai Ma
Objectives: To develop and validate an MRI radiomics-based decision support tool for the automated grading of cervical disc degeneration.Methods: The retrospective study included 2,610 cervical disc samples of 435 patients from two hospitals. The cervical magnetic resonance imaging (MRI) analysis of patients confirmed cervical disc degeneration grades using the Pfirrmann grading system. A training set (1,830 samples of 305 patients) and an independent test set (780 samples of 130 patients) were divided for the construction and validation of the machine learning model, respectively. We provided a fine-tuned MedSAM model for automated cervical disc segmentation. Then, we extracted 924 radiomic features from each segmented disc in T1 and T2 MRI modalities. All features were processed and selected using minimum redundancy maximum relevance (mRMR) and multiple machine learning algorithms. Meanwhile, the radiomics models of various machine learning algorithms and MRI images were constructed and compared. Finally, the combined radiomics model was constructed in the training set and validated in the test set. Radiomic feature mapping was provided for auxiliary diagnosis.Results: Of the 2,610 cervical disc samples, 794 (30.4%) were classified as low grade and 1,816 (69.6%) were classified as high grade. The fine-tuned MedSAM model achieved good segmentation performance, with the mean Dice coefficient of 0.93. Higher-order texture features contributed to the dominant force in the diagnostic task (80%). Among various machine learning models, random forest performed better than the other algorithms (p < 0.01), and the T2 MRI radiomics model showed better results than T1 MRI in the diagnostic performance (p < 0.05). The final combined radiomics model had an area under the receiver operating characteristic curve (AUC) of 0.95, an accuracy of 89.51%, a precision of 87.07%, a recall of 98.83%, and an F1 score of 0.93 in the test set, which were all better than those of other models (p < 0.05).Conclusion: The radiomics-based decision support tool using T1 and T2 MRI modalities can be used for cervical disc degeneration grading, facilitating individualized management.

2 September 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
XJXuehai Jia
Xuehai Jia
CSChangyong Shen
Changyong Shen
BLBin Luo
Bin Luo
YYYi Yang
Yi Yang
KZKerui Zhang
Kerui Zhang
LMLitai Ma
Litai Ma
Background: Although the specific relationship between the stress changes in the external fixator during tibial fracture treatment and the bone healing process remains unclear, it is believed that stress variations in the external fixator scaffold can, to a certain extent, reflect the progress of tibial healing.Objective: This study aims to propose a non‐invasive method for assessing the degree of fracture healing by monitoring the changes in stress transmission, the locations of stress‐sensitive points, and displacement in the external fixator‐tibia system during the healing process of tibial fractures.Methods: In this study, finite element models of tibial fractures at various healing stages were developed. Physiological conditions, including axial, torsional, and bending loads on the tibia, were simulated to evaluate stress and strain within the external scaffold‐tibia system under normal physiological loading conditions.Results: The results indicate variations in the stress distribution between the external fixator and the tibia during different stages of healing. In the early phase of fracture healing, the external fixator plays a crucial role as the primary load‐bearing unit under all three loading conditions. As the fracture healing progresses, the stress on the tibia gradually increases, concentrating on the medial part of the tibia under axial and torsional loading, and at the upper and lower ends, as well as the central part of the anterior and posterior tibia during bending loading. The stress at the callus gradually increases, while micro‐movements decrease. The stress within the external bracket gradually decreases, with a tendency for the connecting rod to transfer stress towards the screws. Throughout the fracture healing process, the location of maximum stress in the external fixator remains unchanged. Under axial and torsional loading, the maximum stress is located at the intersection of the lowest screw and the bone cortex, while under bending loading, it is at the intersection of the second screw and the connecting rod.Conclusion: During the bone healing process, stress is transferred between the external fixation frame and the bone. As bone healing advances, the stress on the connecting rods and screws of the external fixation frame decreases, and the amplitude of stress changes diminishes. When complete and robust fusion is achieved, stress variations stabilize, and the location of maximum stress on the external fixation frame remains unchanged. The intersections of the lowest screw and the bone cortex, as well as the second screw and the connecting rod, can serve as sensitive points for monitoring the degree of bone healing.

20 June 2025 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
KZKe-Rui Zhang
Ke-Rui Zhang
BLBin Luo
Bin Luo
JTJu Tu
Ju Tu
YLYa-Qin Li
Ya-Qin Li
JWJun Wen
Jun Wen
YYYi Yang
Yi Yang
Introduction: Distal tibial fractures are common fracture sites and usually require surgical treatment to achieve anatomical reduction. Intramedullary nails (IMN) are widely used in orthopedics for stabilizing fractured bones and treating limb deformities. The process of postoperative bone healing is of great significance for patient rehabilitation and can guide subsequent treatment methods. However, the current radiographic techniques used to determine the degree of fusion, such as X-ray, need to be improved in accuracy and have some radiation effects. Several studies suggested that the mechanical load on the fracture area could reflect the bone healing process and evaluated the stability of fracture area. The aim of this study is to investigate the biomechanical changes in the fracture area during bone healing and IMN, and to prepare for the subsequent placement of intelligent stress and displacement sensors based on the changes in stress and displacement, in order to provide guidance for the treatment and rehabilitation of postoperative fractures.Methods: Finite element (FE) models representing different healing stages of tibial fractures were developed. All conditions were applied to simulate the stress and strain of the IMN fixation system under normal tibial stress.Results: The stress at the fracture area on the IMN gradually decreases, while the stress on the callus gradually increases until reaching a stable state at the 12th week after surgery. And the deformation value and the displacement value of the callus decrease and stabilize over time. Based on the changes in stress at the fracture area of the IMN and the displacement value of the callus, we can place a stress sensor at the fracture area of the IMN and a displacement sensor at the callus area.Conclusion: This study utilized FE analysis to evaluate stress, deformation and displacement between the IMN and bone during the healing process of tibial fractures in four stages. By combining these aspects, the degree of bone healing can be assessed. This research enables orthopedic doctors to monitor the progression of fracture healing without relying solely on imaging examinations. Furthermore, it aids in guiding patients to undergo appropriate rehabilitation training for better recovery.