Elderly or disabled people usually need augmented nursing attention both in home and clinical environments, especially to perform bathing activities. The development of an assistive robotic bath system, which constitutes a central motivation of this letter, would increase the independence and safety of this procedure, ameliorating in this way the everyday life for this group of people. In general terms, the main goal of this letter is to enable natural, physical human-robot interaction, involving human-friendly and user-adaptive online robot motion planning and interaction control. For this purpose, we employ imitation learning using a leader-follower framework called coordinate change dynamic movement primitives (CC-DMP), in order to incorporate the expertise of professional carers for bathing sequences. In this letter, we propose a vision-based washing system, combining CC-DMP framework with a perception-based controller, to adapt the motion of robot's end effector on moving and deformable surfaces, such as a human body part. The controller guarantees globally uniformly asymptotic convergence to the leader movement primitive while ensuring avoidance of restricted areas, such as sensitive skin body areas. We experimentally tested our approach on a setup including the humanoid robot ARMAR-III and a Kinect v2 camera. The robot executes motions learned from the publicly available KIT whole-body human motion database, achieving good tracking performance in challenging interactive task scenarios.
22 July 2019 in IEEE Robotics and Automation Letters
In this letter, we tackle the problem of adapting the motion of a robotic assistant rollator to patients with different mobility status. The goal is to achieve a coupled human–robot motion in a front-following setting as if the patient was pushing the rollator himself/herself. To this end, we propose a novel approach using model-based reinforcement learning (MBRL) for adapting the control policy of the robotic assistant. This approach encapsulates our previous work on human tracking and gait analysis from RGB-D and laser streams into a human-in-the-loop decision making strategy. We use long short-term memory (LSTM) networks for designing a human motion intention model and a coupling parameters forecast model, leveraging on the outcome of human gait analysis. An initial LSTM-based policy network was trained via imitation learning from human demonstrations in a motion capture setup. This policy is then fine-tuned with the MBRL framework using tracking data from real patients. A thorough evaluation analysis proves the efficiency of the MBRL approach as a user-adaptive controller.
Artificial intelligence (AI) is increasingly applied in a wide range of healthcare and Intensive Care Unit (ICU) areas to serve—among others—as a tool for disease detection and prediction, as well as for healthcare resources’ management. Since sepsis is a high mortality and rapidly developing organ dysfunction disease afflicting millions in ICUs and costing huge amounts to treat, the area can benefit from the use of AI tools for early and informed diagnosis and antibiotic administration. Additionally, resource allocation plays a crucial role when patient flow is increased, and resources are limited. At the same time, sensitive data use raises the need for ethical guidelines and reflective datasets. Additionally, explainable AI is applied to handle AI opaqueness. This study aims to present existing clinical approaches for infection assessment in terms of scoring systems and diagnostic biomarkers, along with their limitations, and an extensive overview of AI applications in healthcare and ICUs in terms of (a) sepsis detection/prediction and sepsis mortality prediction, (b) length of ICU/hospital stay prediction, and (c) ICU admission/hospitalization prediction after Emergency Department admission, each constituting an important factor towards either prompt interventions and improved patient wellbeing or efficient resource management. Challenges of AI applications in ICU are addressed, along with useful recommendations to mitigate them. Explainable AI applications in ICU are described, and their value in validating, and translating predictions in the clinical setting is highlighted. The most important findings and future directions including multimodal data use and Transformer-based models are discussed. The goal is to make research in AI advances in ICU and particularly sepsis prediction more accessible and provide useful directions on future work.
Objective: To assess the concurrent validity of a smart walker–integrated gait analysis system with the GAITRite® system for measuring spatiotemporal gait parameters in potential users of the smart walker. Design: Criterion standard validation study. Setting: Research laboratory in a geriatric hospital. Participants: Twenty-five older adults (⩾65 years) with gait impairments (habitual rollator use and/or gait speed <0.6 m/s) and no severe cognitive impairment (Mini-Mental State Examination ⩾17). Main measures: Stride, swing and stance time; stride length; and gait speed were simultaneously recorded using the smart walker–integrated gait analysis system and the GAITRite system while participants walked along a 7.8-m walkway with the smart walker. Concurrent criterion-related validity was assessed using the Bland–Altman method, percentage errors (acceptable if <30%), and intraclass correlation coefficients for consistency (ICC3,1) and absolute agreement (ICC2,1). Results: Bias for stride, swing and stance time ranged from −0.04 to 0.04 seconds, with acceptable percentage errors (8.7%–23.0%). Stride length and gait speed showed higher bias (meanbias (SD) = 0.20 (0.11) m; 0.19 (0.13) m/s) and not acceptable percentage errors (31.3%–42.3%). Limits of agreement were considerably narrower for temporal than for spatial-related gait parameters. All gait parameters showed good-to-excellent consistency (ICC3,1 = 0.72–0.97). Absolute agreement was good-to-excellent for temporal (ICC2,1 = 0.72–0.97) but only poor-to-fair for spatial-related gait parameters (ICC2,1 = 0.37–0.52). Conclusion: The smart walker–integrated gait analysis system has good concurrent validity with the GAITRite system for measuring temporal but not spatial-related gait parameters in potential end-users of the smart walker. Stride length and gait speed can be measured with good consistency, but with only limited absolute accuracy.
This chapter will approach this challenge of balancing the opacity and value of efficiency that often sits at the heart of technology design, with the openness and individual voice required for functional democracy. It will do so by looking at the challenge from a number of different perspectives. The first of these will be the perspective of technological design and data. AI and big data systems are notoriously closed and opaque, and corporate approaches to the collection of training and testing data have not always respected human values and democratic principles. The second perspective will focus on policies and principles, and the way in which we can create a common understanding not just of how these systems should be designed, but the constraints we need to place on how they are used, and with and for whom. Finally, we will look at the way in which both users and policymakers can be encouraged to develop a refined and enhanced sense of critical digital literacy so as to improve both the agency of the end user and the policymaker, fostering the emergence of the model of democracy-in-the-loop through the introduction of production friction.