William Rà

Dr. William Rà


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
GAGiuseppe Amato
Giuseppe Amato
RPRoberto Puleio
Roberto Puleio
AAAntonino Agrusa
Antonino Agrusa
VRVito Rodolico
Vito Rodolico
LCLuca Cicero
Luca Cicero
GRGiorgio Romano
Giorgio Romano
Despite significant advancements, prosthetic hernia repair continues to face unacceptably high complication rates. These likely stem from poor biological responses, such as stiff scar tissue leading to mesh shrinkage. To overcome these issues, the Stenting and Shielding (S&S) Hernia System, a newly designed 3D dynamic device, has been developed for dissection-free laparoscopic placement to permanently obliterate hernia defects. Unlike conventional meshes, this device induces a regenerative biological response, promoting viable tissue growth rather than fibrotic plaque formation. In a porcine experimental model, the S&S device demonstrated the development of a great amount of muscle fibers, alongside nervous and vascular structures, within well-perfused connective tissue. Histological analysis of biopsy specimens excised from the experimental animals revealed progressive muscle fiber maturation from early myocyte development in the short term to fully developed muscle bundles in the long term. The enhanced biological response observed with the S&S device suggests a promising shift in hernia repair, potentially reversing the degenerative processes of hernia formation and promoting tissue regeneration. The S&S Hernia System described here can be classified not merely as a conventional hernia implant, but as part of a new category of hernia devices: the dynamic regenerative scaffold.

18 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GAGiuseppe Amato
Giuseppe Amato
GRGiorgio Romano
Giorgio Romano
PRPuleio Roberto
Puleio Roberto
GBgiuseppe di buono
giuseppe di buono
LCLuca Cicero
Luca Cicero
AAAntonino Agrusa
Antonino Agrusa
Conventional hernia repair using static flat meshes is often associated with complications casused by extensive dissection, implant fixation, and poor biological response. The Stenting & Shielding (S&S) Hernia System offers a novel solution designed for dissection-free, fixation-free hernia repair. The S&S Hernia System has been evaluated in a porcine model, focusing on procedural simplicity, device retention and regenerative properties. The experimental study involved 10 pigs, each implanted with two S&S devices. Follow-up assessments included ultrasound, laparoscopic examinations, and histological analyses over a period ranging from 4 weeks to 8 months post-implantation. The S&S Hernia System, made from medical-grade polypropylene-based thermoplastic elastomer (TPE), features a rayed 3D scaffold and an oval shield connected by a mast. Delivered and positioned intraabdominally without dissection, the device transforms into a self-retaining scaffold to obliterate the hernia defect. Primary outcomes included ease of delivery, visceral adhesion formation, and device retention, ensuring no dislocation. Secondary outcomes evaluated histological evidence of tissue regeneration, including the development of connective tissue, muscles, vessels, and nerves within the scaffold. Immunohistochemistry was used to detect tissue growth factors promoting regeneration of the abdominal wall's typical components. All 20 implanted devices remained securely in place without dislocation. Transient adhesion bands were observed in two shields at 1 month but resolved by 3 months. No visceral adhesions were detected at the time of animal sacrifice. Histological analyses demonstrated tissue regeneration within the scaffold, while immunohistochemistry confirmed the presence of growth factors supporting regeneration. Overall, the S&S Hernia System showed promising results in a porcine model, with no dislocation and evident regenerative potential. Its rapid, dissection-free delivery and compliance with abdominal wall dynamics simplify the procedure while minimizing adhesions. These findings warrant further clinical investigation to validate its application in human patients.

31 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GAGiuseppe Amato
Giuseppe Amato
RPRoberto Puleio
Roberto Puleio
GRGiorgio Romano
Giorgio Romano
GBgiuseppe di buono
giuseppe di buono
GCGiovanni Cassata
Giovanni Cassata
VRVito Rodolico
Vito Rodolico
The current gold standard for abdominal hernia repair involves the use of flat meshes deployed over the hernial defect via open or laparoscopic surgery. However, these conventional methods often lead to complications related to implant fixation, suboptimal biological response, and inadequate defect management. To address these challenges, a novel treatment approach has been developed using the Stenting & Shielding (S&S) Hernia System. This innovative device is laparoscopically introduced into the hernial opening without requiring tissue dissection, and it expands to permanently obliterate the defect without the need for fixation. Unlike the foreign body reaction typically observed with flat meshes, the 3D design of the S&S device exhibits dynamic responsiveness, promoting true tissue regeneration. By moving in harmony with the abdominal wall, the S&S device attracts growth factors that induce the formation and maturation of new muscular, vascular, and nervous structures, effectively restoring the integrity of the abdominal wall compromised by hernia disease. This regenerative capability was demonstrated in an experimental porcine model, where the S&S device was implanted and biopsies were taken at defined postoperative intervals ranging from 4 weeks to 8 months. Immunohistochemical analysis of these biopsies revealed the presence of specific tissue growth factors driving the regenerative processes. The results suggest that the three-dimensional design of the S&S Hernia System enables the device to respond to dynamic mechanical strains, thereby fostering progressive tissue regeneration.

30 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GAGiuseppe Amato
Giuseppe Amato
AAAntonino Agrusa
Antonino Agrusa
VRVito Rodolico
Vito Rodolico
RPRoberto Puleio
Roberto Puleio
GBgiuseppe di buono
giuseppe di buono
WRWilliam Rà
William Rà
Introduction: The biological response to implants used for hernia repair remains a topic of ongoing discussions. Traditional static hernia meshes often lead to poor-quality fibrotic tissue ingrowth, mesh shrinkage, and complications such as nerve entrapment. These issues are particularly problematic in groin hernia repairs, where scar tissue can impair movement and cause discomfort. To address these challenges, the dynamic Stenting & Shielding (S&S) Hernia System was developed, promoting a regenerative biological feature that induces the development of new muscles, nerves, and blood vessels. Materials and Methods: This study evaluated the quantity and quality of vascular development within the 3D scaffold of the S&S device implanted in the lower abdominal wall of pigs, with assessments made at various post-implantation stages. Results: Early-stage post-implantation revealed extensive angiogenesis within the S&S device excised from the pigs. The quantity and quality of arteries and veins progressively increased, reaching full development in the midterm after placement in the abdominal wall of the animals. Notably, no inflammatory reactions or stiff scar tissue were observed within the 3D scaffold of the S&S device even long term. Conclusion: High quality tissue development in hernia devices requires robust vascular support. The extensive network of mature arteries and veins observed in the S&S Hernia System underscores its regenerative capabilities, making it a promising solution for the cure of abdominal wall protrusions.

30 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GAGiuseppe Amato
Giuseppe Amato
RPRoberto Puleio
Roberto Puleio
AAAntonino Agrusa
Antonino Agrusa
VRVito Rodolico
Vito Rodolico
LCLuca Cicero
Luca Cicero
WRWilliam Rà
William Rà
Despite significant advancements, prosthetic hernia repair continues to face unacceptably high complication rates, including postoperative discomfort and chronic pain. These issues often stem from poor biological responses, such as the formation of stiff scar tissue and mesh shrinkage, commonly associated with traditional static meshes and plugs. Recent studies have challenged the conventional approach of reinforcing the groin through fibrotic incorporation of meshes, particularly in light of new evidence on the degenerative origins of many types of abdominal hernias such as groin hernias. In response, the Stenting & Shielding (S&S) Hernia System, a newly designed 3D dynamic device, has been developed for dissection free laparoscopic placement to permanently obliterate hernia defects. Unlike conventional meshes, this device induces a probiotic biological response, promoting viable tissue growth rather than fibrotic plaque formation. In a porcine experimental model, the S&S device demonstrated the development of a great amount of muscle fibers, alongside nervous and vascular structures, within well-perfused connective tissue. Histological analysis of biopsy specimen excised from the experimental animals revealed progressive muscle fiber maturation from early myocyte development in the short term to fully developed muscle bundles in the long term. The enhanced biological response observed with the S&S device suggests a promising shift in hernia repair, potentially reversing the degenerative processes of hernia formation and promoting tissue regeneration. The S&S Hernia System described here can be classified not merely as a conventional hernia implant, but as part of a new category of hernia devices: the dynamic regenerative scaffold.