A thermal neutron-absorbing metal matrix composite (MMC) comprised of Al3Hf particles in an aluminum matrix was developed to filter out thermal neutrons and create a fast flux environment for material testing in a mixed-spectrum nuclear reactor. Intermetallic Al3Hf particles capture thermal neutrons and are embedded in a highly conductive aluminum matrix that provides conductive cooling of the heat generated due to thermal neutron capture by the hafnium. These Al3Hf-Al MMCs were fabricated using powder metallurgy via hot pressing. The specimens were neutron-irradiated to between 1.12 and 5.38 dpa and temperatures ranging from 286 °C to 400 °C. The post-irradiation examination included microstructure characterization using transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy. This study reports the microstructural observations of four irradiated samples and one unirradiated control sample. All the samples showed the presence of oxide at the particle–matrix interface. The irradiated specimens revealed needle-like structures that extended from the surface of the Al3Hf particles into the Al matrix. An automated segmentation tool was implemented based on a YOLO11 computer vision-based approach to identify dislocation lines and loops in TEM images of the irradiated Al-Al3Hf MMCs. This work provides insight into the microstructural stability of Al3Hf-Al MMCs under irradiation, supporting their consideration as a novel neutron absorber that enables advanced spectral tailoring.
Well-defined supported metal nanoparticle catalysts, with high uniformity in particle sizes of the dispersed metal, are crucial for studying their catalyzed reactions that exhibit structure sensitivity. For such catalysts, conventional methods of preparation may prove unsuitable in controlling the nanoparticle size and distribution. In this work, the systematic growth of supported Pd and Pt particles was achieved through the method of electroless deposition (ED), in which additional metal was deposited on preexisting particles of the same metal. The ED process was investigated by varying the pump time, pump speed, and molar ratios of the reagents during the continuous addition of the metal precursor, as well as the reducing agent and stabilizer, which were hydrazine and ethylenediamine, respectively. This allowed for the precise control of deposition rates, thus regulating the supported metal particle size, size distribution, and particle density. A slower deposition rate was achieved by increasing the amount of the ethylenediamine stabilizer and lowering the pumping speed. Slower rates of deposition resulted in smaller particle sizes and tighter size distributions compared to other preparations with the same metal weight loading, as characterized via X-ray diffraction (XRD), chemisorption, and scanning-transmission electron microscopy (STEM) methods.
Oxide Dispersion Strengthened (ODS) alloys are considered as promising nuclear materials for the next generation advanced nuclear reactors due to their improved elevated temperature mechanical properties and radiation damage resistance [ 1, 2]. MA956 is a commercial ODS alloy with superior oxidation resistance and creep strength at elevated temperatures. The improved properties for ODS alloys can be attributed to the presence of dispersed nanosized oxide particles. These oxide particles can act as barriers to dislocation motion and provide additional sinks and sites for point defect recombination [ 3]. Hence, their stability can greatly affect the properties of the irradiated ODS alloys. Besides, irradiation will induce defects into the ODS alloys, and these defects can develop further as irradiation dose increases [ 4]. The defects propagation can significantly undermine the mechanical properties of the bulk materials, resulting in irradiation hardening and lower ductility. Therefore, it is necessary to have a good understanding of the defect’s evolution with irradiation. Hence, efforts are ongoing to understand the effect of ion irradiation on ODS MA956 with emphasis on oxide particles and evolution of defects as a function of dose (2.5, 50 and 100 dpa).
A thermal neutron absorber material composed of Al3Hf particles in an aluminum matrix is under development for the Advanced Test Reactor. This metal matrix composite was fabricated via hot pressing of high-purity aluminum and micrometer-size Al3Hf powders at volume fractions of 20.0, 28.4, and 36.5%. Room temperature tensile and hardness testing of unirradiated specimens revealed a linear relationship between volume fraction and strength, while the tensile data showed a strong decrease in elongation between the 20 and 36.5% volume fraction materials. Tensile tests conducted at 200 °C on unirradiated material revealed similar trends. Evaluations were then conducted on specimens irradiated at 66 to 75 °C to four dose levels ranging from approximately 1 to 4 dpa. Tensile properties exhibited the typical increase in strength and decrease in ductility with dose that are common for metallic materials irradiated at ≤0.4Tm. Hardness also increased with neutron dose. The difference in strength between the three different volume fraction materials was roughly constant as the dose increased. Nanoindentation measurements of Al3Hf particles in the 28.4 vol% material showed the expected trend of increased hardness with irradiation dose. Transmission electron microscopy revealed oxygen at the interface between the Al3Hf particles and aluminum matrix in the irradiated material. Scanning electron microscopy of the exterior surface of tensile tested specimens revealed that deformation of the material occurs via plastic deformation of the Al matrix, cracking of the Al3Hf particles, and to a lesser extent, tearing of the matrix away from the particles. The fracture surface of an irradiated 28.4 vol% specimen showed failure by brittle fracture in the particles and ductile tearing of the aluminum matrix with no loss of cohesion between the particles and matrix. The coefficient of thermal expansion decreased upon irradiation, with a maximum change of −6.3% for the annealed irradiated 36.5 vol% specimen.