This study aimed to evaluate whether horizontal continuous and apical stretching sutures could reduce FGG shrinkage. In this randomized controlled clinical trial ten patients (20 sites, seven females and three males) ranging from 18 to 53 years (average 39 years) with insufficient keratinized and attached gingiva received FGG in two quadrants of mandible (splitmouth design). Horizontal continuous and apical stretching sutures were used in test sites in addition to common suturing techniques. Clinical parameters including probing depth (PD), the width of keratinized and attached gingiva (KG, AG), the horizontal and vertical dimension of the graft (HD, VD), and graft area (GA) were recorded at baseline and 1, 3, and six months after the operation. PD did not differ significantly for six months. The average change of other parameters in test and control sites respectively was as follows: KG increased 5.5 mm and 5.1 mm, AG increased 5.3 mm and 5.1 mm, HD shrinkage was 21.6% and 15.8%, VD shrinkage was 33.7% and 33.2%, GA shrinkage was 47.3% and 43.3%. There were no significant differences between test and control sites in clinical parameters six months after surgery. Application of horizontal continuous and apical stretching sutures does not reduce FGG shrinkage.
13 December 2023 in Clinical Implant Dentistry and Related Research
Purpose: To compare pro‐inflammatory cytokine levels in the peri‐implant crevicular fluid (PICF) in unused and reused healing abutments.Materials and methods: This study was a controlled randomized, double‐blind clinical trial. Seventy‐two patients who met the inclusion criteria were divided into two groups. After one‐stage implant placement, in group A, an unused healing abutment, and in group B, a reused healing abutment, was connected to the implant fixture. After 2 months, clinical measurements for keratinized gingiva (KG), plaque index (PI), and bleeding index (BI) (Ainamo and Bay) were taken, and PICF sampling was performed to evaluate pro‐inflammatory IL‐1β and TNF‐α cytokine levels using the ELISA test. Comparison of clinical measurements and cytokine levels between the two study groups was made using the Mann‐Whitney test.Result: Clinical measurements and sampling were performed on 60 patients (nA = 27, nB = 33). There was no significant difference between the two groups in clinical measurements (BI (p = 0.96) and PI (p = 0.06)) or TNF‐α (p = 0.63), and IL‐1β (p = 0.26) cytokine levels.Conclusion: Reused healing abutments that are cleaned and sterilized properly do not appear to induce further peri‐implant pro‐inflammatory response; therefore, they can be utilized temporarily until implant abutment insertion.
Ultra-soft bristles are recommended for individuals with gingival recession, dentinal hypersensitivity, and patients who have undergone periodontal surgeries. However, comparative effectiveness of ultra-soft toothbrushes on dental plaque and bleeding indices has not extensively been studied, and a consensus has yet to be reached on their efficacy. The aim of this study was to investigate the effect of ultra-soft toothbrushes with different commercial brands on plaque and bleeding indices. In this crossover randomized clinical trial, 30 participants were selected using convenience sampling method. The subjects were randomly divided into three groups (n=10). In the first session, the bleeding index was recorded. Then each subject was given a toothbrush (Oral B, GUM, or Fuchs), asked to brush at least twice a day using the Bass technique, then avoid brushing for 24 hours after a week and refer for recording the indices. During the second session, bleeding on probing was recorded before brushing, and plaque indices were recorded before and after brushing. Plaque indices before brushing were considered the baseline plaque indices. After one week of washout, each subject used the next toothbrush in terms of the group involved. Turesky plaque index, O'Leary plaque index, and bleeding index were evaluated. The distribution of data was normal. Therefore, ANOVA, t-test, and post hoc tests were used for the analysis of data. The bleeding and plaque indices decreased significantly compared to the baseline with the use of all the three ultra-soft toothbrushes evaluated (p< 0.05), with no significant differences between the three brands (p> 0.05) except for the superiority of Fuchs toothbrush in decreasing the Turesky plaque index. Ultra-soft toothbrushes can reduce plaque index compared to the baseline, but they do not decrease the plaque index up to the optimal level, which might affect their prescription.