Junko Shimazaki

Dr. Junko Shimazaki

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Journal of Physics: Energy
Verified
Journal Article
Open access
PDF file
ILIn-Young Lee
In-Young Lee
JSJunko Shimazaki
Junko Shimazaki
WTWakako Tsugawa
Wakako Tsugawa
KIKazunori Ikebukuro
Kazunori Ikebukuro
Koji SodeKoji Sode
Koji Sode
Diabetes mellitus is a disorder in which the body does not produce enough or respond normally to insulin; consequently, blood glucose levels increase to become abnormally high. Accordingly, the primary treatment of diabetes is to control glycemic levels continuously. To continuously control glycemic levels, several medical devices have been developed to monitor blood glucose levels, represented by sensors and monitors for the self-monitoring of blood glucose. The ultimate goal for those engaged in research to develop medical devices is to develop implantable biodevices, namely self-powered autonomously operated artificial pancreas systems. One of the most challenging issues in realizing an implantable artificial pancreas is the long-term continuous supply of electricity, which is currently dependent on rechargeable batteries, requiring periodical replacement. In this work, we report the development of a direct electron transfer type enzyme-based miniaturized self-powered glucose sensor based on the BioCapacitor principle with a micro-sized enzyme anode area (0.15 mm × 0.75 mm), which has only 0.1 mm2 of electrode surface. As a result, a BioCapacitor utilizing a biofuel cell with a micro-sized enzyme anode was operated by self-power. In addition, the glucose concentration was detected within the range from 13 mM to 100 mM based on the frequency of charge/discharge cycles of the BioCapacitor. Although further improvement of the current density of the micro-sized anode is necessary to monitor a glucose concentration range lower than 13 mM, this self-powered glucose sensor with a micro-sized electrode based on the BioCapacitor principle was operated continuously for 6.6 h at 37 °C in 100 mM potassium phosphate buffer (pH 7.0). Our success indicates the potential to realize self-powered, autonomous, and implantable sensing modules for bio devices such as glucose-sensing systems for an artificial pancreas.

Verified
Journal Article
Open access
PDF file
TYTakumi Yanase
Takumi Yanase
JSJunko Shimazaki
Junko Shimazaki
RARyutaro ASANO
Ryutaro ASANO
KIKazunori Ikebukuro
Kazunori Ikebukuro
Koji SodeKoji Sode
Koji Sode
WTWakako Tsugawa
Wakako Tsugawa
The electrochemical enzyme sensors based on direct electron transfer (DET)-type oxidoreductase-based enzymes are ideal for continuous and in vivo monitoring. However, the number and types of DET-type oxidoreductases are limited. The aim of this research is the development of a versatile method to create a DET-type oxidoreductase complex based on the SpyCatcher/SpyTag technique by preparing SpyCatcher-fused heme c and SpyTag-fused non-DET-type oxidoreductases, and by the in vitro formation of DET-type oxidoreductase complexes. A heme c containing an electron transfer protein derived from Rhizobium radiobacter (CYTc) was selected to prepare SpyCatcher-fused heme c. Three non-DET-type oxidoreductases were selected as candidates for the SpyTag-fused enzyme: fungi-derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase (GDH), an engineered FAD-dependent d-amino acid oxidase (DAAOx), and an engineered FMN-dependent l-lactate oxidase (LOx). CYTc-SpyCatcher (CYTc-SC) and SpyTag-Enzymes (ST-GDH, ST-DAAOx, ST-LOx) were prepared as soluble molecules while maintaining their redox properties and catalytic activities, respectively. CYTc-SC/ST-Enzyme complexes were formed by mixing CYTc-SpyCatcher and SpyTag-Enzymes, and the complexes retained their original enzymatic activity. Remarkably, the heme domain served as an electron acceptor from complexed enzymes by intramolecular electron transfer; consequently, all constructed CYTc-SC/ST-Enzyme complexes showed DET ability to the electrode, demonstrating the versatility of this method.

26 August 2026 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
MHMika Hatada
Mika Hatada
JSJunko Shimazaki
Junko Shimazaki
Koji SodeKoji Sode
Koji Sode
Biosensors, utilizing glucose oxidoreductases as biological recognition elements (BREs), underpin current blood glucose monitoring (BGM) and continuous glucose monitoring (CGM) technologies. Glucose oxidase remains the gold standard due to its high selectivity and stability, yet its oxygen dependency limits it to first- and second-generation sensing. Fungal flavin adenine dinucletotide (FAD)-dependent glucose dehydrogenase (GDH) has emerged as the standard for mediator-based second-generation sensors due to its oxygen insensitivity, though it requires further engineering to match the stability and selectivity for CGM applications. Recent research increasingly prioritizes third-generation sensors capable of direct electron transfer (DET). Bacterial FADGDHs are premier candidates, possessing intrinsic DET capabilities via dedicated covalently bound heme subunits, while cellobiose dehydrogenase represents a rising star utilizing non-covalently bound heme b as a built-in mediator. Both require extensive protein engineering to overcome inherent limitations in substrate specificity and catalytic efficiency toward glucose. This review introduces the protein and enzyme sciences of glucose oxidoreductases, which have been and expected to be applied to blood, interstitial fluid, and other biological fluids. It reviews their reported and expected sensing modalities and engineering strategies, including rational design and chimera construction, to enhance enzyme robustness, selectivity, and the availability of electron acceptors, including DET ability. It also introduces perspectives on future engineering approaches to create ideal glucose-sensing oxidoreductases. This review article is an updated version of “Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird’s Eye View of Glucose Sensing Enzymes,” which was published in 2011 in the Journal of Diabetes Science and Technology (JDST) ( https://doi.org/10.1177/193229681100500507 ).

Verified
Journal Article
Open access
PDF file
HXHoucheng Xue
Houcheng Xue
TYTakumi Yanase
Takumi Yanase
JSJunko Shimazaki
Junko Shimazaki
HKHaruka Kawai
Haruka Kawai
DMDaimei Miura
Daimei Miura
WTWakako Tsugawa
Wakako Tsugawa
Nicotinoproteins are a group of NAD+-dependent dehydrogenases that bind NAD+ tightly and catalyze reactions without using free NAD+. In this study, we investigated the role of the unique insertion loop in nicotinoproteins. Carveol dehydrogenase (CADh), a short-chain dehydrogenase/reductase (SDR) nicotinoprotein, and β-hydroxybutyrate dehydrogenase from Alcaligenes faecalis (AfBHBDh), a non-nicotinoprotein counterpart, were used as model enzymes. An insertion loop-deleted mutant, CADh Δ39–49, was constructed. An insertion loop from Mycobacterium paratuberculosis CADh (MpCADh) was introduced into AfBHBDh to generate the two mutants. The results showed that CADh Δ39–49 lost NAD+ tight binding capacity and could not utilize free NAD+. In contrast, the AfBHBDh mutants showed no dye-mediated dehydrogenase activity. Moreover, the KM and KD values for NAD+ were higher than those of the wild-type enzyme. Docking simulations revealed a stronger binding affinity between NAD+ and the mutants than with the wild-type AfBHBDh. Taken together, these results suggest that the insertion loop interferes with NAD+ entry into the active site of the enzyme while creating a more energetically favorable binding environment. This loop is necessary but alone is insufficient to achieve NAD+ tight binding. This study deepens understanding of NAD+ binding in SDR nicotinoproteins and provides insights for SDR enzyme engineering.

9 October 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
STSheng Tong
Sheng Tong
YYYuki Yaegashi
Yuki Yaegashi
MFMao Fukushi
Mao Fukushi
TYTakumi Yanase
Takumi Yanase
JSJunko Shimazaki
Junko Shimazaki
WTWakako Tsugawa
Wakako Tsugawa
This study reports on the direct electron transfer (DET) ability of the enzyme spermidine dehydrogenase (SpDH) and its use in a DET-type enzymatic sensor for detecting spermine. SpDH was found to exhibit internal electron transfer from its cofactor, flavin adenine dinucleotide (FAD), to heme b. This was confirmed by observing the heme b-derived reduction peak at 560 nm in the presence of spermine, the substrate. SpDH was immobilized on a gold electrode via a dithiobis (succinimidyl hexanoate) self-assembled monolayer. The cyclic voltammetry analysis of the SpDH-immobilized gold electrode revealed an increased oxidation current in the presence of 0.1 mM spermine with an onset potential of −0.14 V vs. Ag/AgCl in the absence of an additional external electron acceptor. This result confirmed that SpDH is capable of DET. Chronoamperometric analyses were conducted using an SpDH-immobilized gold electrode with spermine as the substrate under a 0 V oxidation potential vs. Ag/AgCl using an artificial saliva matrix containing 10 µM ascorbic acid and 100 µM uric acid. The sensor exhibited good linear correlation between the current increase and spermine concentration from 0.2 to 2.0 µM, with a limit of detection of 0.084 µM, which encompasses the physiologically relevant spermine concentration found in the saliva. Primary structure alignments and 3D structure predictions revealed that all SpDH homologs possess two conserved histidine residues in the same location on the surface as the heme b ligand of SpDH. This indicates their potential for DET-ability with an electrode.