In this study, we developed a colloidal gold immunochromatographic strip (CGIS) method that used the matrix-matched calibration curves of contamination ratio models to quantitatively determine the total aflatoxin in five herbal medicines. This approach addresses issues related to false results and poor accuracy associated with conventional methods. The CGIS was analyzed using a Vertu touch reader, and the matrix-matched calibration was established based on the absorbance ratios of the T and C lines, as well as the logarithmic values of the total aflatoxin concentrations. The total aflatoxins could be accurately and digitally detected from 2.5 to 40 μg/kg, and the LOD of total aflatoxins was 1 μg/kg in the five herbal medicines. The recovery rates from the spiked samples ranged from 65.1% to 98.6%, and the RSD was less than 16.9%. A total of 229 samples were analyzed by both CGIS and HPLC-FLD, with agreement ranging from 78.4% to 132.6% (Arecae semen), 82.6% to 133.0% (Nelumbinis semen), 79.9% to 117.9% (Coicis semen), 78.1% to 119.0% (Platycladi semen), and 76.1% to 123.0% (Ziziphi spinosae semen). This process for the discrimination of the CGIS results was established to assess if samples met the requirement of aflatoxin limits, which could save approximately 75% in time and reduce the workload of retesting by a designated confirmatory reference method to less than 10%. This study demonstrated that the application of matrix-matched calibration curves based on contamination ratio models to CGIS can effectively enhance the rapid quantitative determination capability of total aflatoxins in herbal medicine matrices.
Puberulic acid (PA) is a mycotoxin produced by a species of Penicillium. It has received widespread attention as a significant contributor to the reported fatalities associated with red yeast rice dietary supplements. However, the detection of PA, especially at low concentration levels, poses a considerable challenge, with no detection methods reported thus far. Here, we present a simple and sensitive derivatization-based LC-MS/MS method, requiring no purification processes, for determination of PA in the red yeast rice. The methylating derivatization with trimethylsilyldiazomethane (TMSCHN2) was performed to enhance its analytical performance. To achieve optimal detection sensitivity, the amount of solvent and TMSCHN2 for the derivatization reaction, along with the reaction time, were individually optimized. Moreover, sample extraction solvent was carefully chosen to improve recoveries in real sample analyses. Comparatively, the proposed LC-MS/MS method achieved a superior detection sensitivity, over 100-fold higher than that of the liquid chromatography method. A good linear relationship within the concentration range of 5 ng/mL to 200 ng/mL (with a linear correlation coefficient of 0.99952) was demonstrated by the method validation. The average recovery rate was between 82.2% and 84.2%, and the repeatability (RSD of 2.1% to 10.4%, n = 6) was satisfactory. The derivatized PA remained stable within 48 h. The limit of detection and the limit of quantification could reach 2 μg/kg and 50 μg/kg, respectively. As a result, the method was successfully applied to detect PA in over 42 batches of the red yeast rice samples. It indicated a low risk of PA contaminations in the red yeast rice products made in China. Furthermore, its application to the other health food products containing red yeast rice demonstrated the applicability of the established method.