Ruopeng Sun

Dr. Ruopeng Sun

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2018 in BMC Geriatrics
Verified
Journal Article
Open access
PDF file
RSRuopeng Sun
Ruopeng Sun
Jacob SosnoffJacob Sosnoff
Jacob Sosnoff
Falls are a major health problem for older adults with significant physical and psychological consequences. A first step of successful fall prevention is to identify those at risk of falling. Recent advancement in sensing technology offers the possibility of objective, low-cost and easy-to-implement fall risk assessment. The objective of this systematic review is to assess the current state of sensing technology on providing objective fall risk assessment in older adults. A systematic review was conducted in accordance to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement (PRISMA). Twenty-two studies out of 855 articles were systematically identified and included in this review. Pertinent methodological features (sensing technique, assessment activities, outcome variables, and fall discrimination/prediction models) were extracted from each article. Four major sensing technologies (inertial sensors, video/depth camera, pressure sensing platform and laser sensing) were reported to provide accurate fall risk diagnostic in older adults. Steady state walking, static/dynamic balance, and functional mobility were used as the assessment activity. A diverse range of diagnostic accuracy across studies (47.9% - 100%) were reported, due to variation in measured kinematic/kinetic parameters and modelling techniques. A wide range of sensor technologies have been utilized in fall risk assessment in older adults. Overall, these devices have the potential to provide an accurate, inexpensive, and easy-to-implement fall risk assessment. However, the variation in measured parameters, assessment tools, sensor sites, movement tasks, and modelling techniques, precludes a firm conclusion on their ability to predict future falls. Future work is needed to determine a clinical meaningful and easy to interpret fall risk diagnosis utilizing sensing technology. Additionally, the gap between functional evaluation and user experience to technology should be addressed.

6 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RSRuopeng Sun
Ruopeng Sun
KHKatherine L. Hsieh
Katherine L. Hsieh
JSJacob J. Sosnoff
Jacob J. Sosnoff
Numerous postural sway metrics have been shown to be sensitive to balance impairment and fall risk in individuals with MS. Yet, there are no guidelines concerning the most appropriate postural sway metrics to monitor impairment. This investigation implemented a machine learning approach to assess the accuracy and feature importance of various postural sway metrics to differentiate individuals with MS from healthy controls as a function of physiological fall risk. 153 participants (50 controls and 103 individuals with MS) underwent a static posturography assessment and a physiological fall risk assessment. Participants were further classified into four subgroups based on fall risk: controls, low-risk MS (n = 34), moderate-risk MS (n = 27), high-risk MS (n = 42). Twenty common sway metrics were derived following standard procedures and subsequently used to train a machine learning algorithm (random forest – RF, with 10-fold cross validation) to predict individuals’ fall risk grouping. The sway-metric based RF classifier had high accuracy in discriminating controls from MS individuals (>86%). Sway sample entropy was identified as the strongest feature for classification of low-risk MS individuals from healthy controls. Whereas for all other comparisons, mediolateral sway amplitude was identified as the strongest predictor for fall risk groupings.

1 December 2022 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
NGNolan Gall
Nolan Gall
RSRuopeng Sun
Ruopeng Sun
MSMatthew Smuck
Matthew Smuck
Introduction: Wrist-worn accelerometer has gained popularity recently in commercial and research use for physical activity tracking. Yet, no consensus exists for standardized wrist-worn data processing, and physical activity data derived from wrist-worn accelerometer cannot be directly compared with data derived from the historically used hip-worn accelerometer. In this work, through a systematic review, we aim to identify and analyze discrepancies between wrist-worn versus hip-worn ActiGraph accelerometers in measuring adult physical activity. Methods: A systematic review was conducted on studies involving free-living data comparison between hip- and wrist-worn ActiGraph accelerometers among adult users. We assessed the population, study protocols, data processing criteria (axis, epoch, wear-time correction, etc.), and outcome measures (step count, sedentary activity time, moderate-to-vigorous physical activity, etc.). Step count and activity count discrepancy were analyzed using meta-analysis, while meta-analysis was not attempted for others due to heterogeneous data processing criteria among the studies. Results: We screened 235 studies with 19 studies qualifying for inclusion in the systematic review. Through meta-analysis, the wrist-worn sensor recorded, on average, 3,537 steps/day more than the hip-worn sensor. Regarding sedentary activity time and moderate-to-vigorous physical activity estimation, the wrist sensor consistently overestimates moderate-to-vigorous physical activity time while underestimating sedentary activity time, with discrepancies ranging from a dozen minutes to several hours. Discussions: Our findings quantified the substantial discrepancies between wrist and hip sensors. It calls attention to the need for a cautious approach to interpreting data from different wear locations. These results may also serve as a reference for data comparisons among studies using different sensor locations.

1 May 2015 in Gait & Posture
Verified
Journal Article
Closed access
RSRuopeng Sun
Ruopeng Sun
RGRichard Guerra
Richard Guerra
JSJohn B. Shea
John B. Shea

11 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
RSRuopeng Sun
Ruopeng Sun
RARoberto G. Aldunate
Roberto G. Aldunate
Jacob SosnoffJacob Sosnoff
Jacob Sosnoff
Functional mobility assessments (i.e., Timed Up and Go) are commonly used clinical tools for mobility and fall risk screening in older adults. In this work, we proposed a new Mixed Reality (MR)-based assessment that utilized a Microsoft HoloLensTM headset to automatically lead and track the performance of functional mobility tests, and subsequently evaluated its validity in comparison with reference inertial sensors. Twenty-two healthy adults (10 older and 12 young adults) participated in this study. An automated functional mobility assessment app was developed, based on the HoloLens platform. The mobility performance was recorded with the headset built-in sensor and reference inertial sensor (Opal, APDM) taped on the headset and lower back. The results indicate that the vertical kinematic measurements by HoloLens were in good agreement with the reference sensor (Normalized RMSE ~ 10%, except for cases where the inertial sensor drift correction was not viable). Additionally, the HoloLens-based test completion time was in perfect agreement with the clinical standard stopwatch measure. Overall, our preliminary investigation indicates that it is possible to use an MR headset to automatically guide users (without severe mobility deficit) to complete common mobility tests, and this approach has the potential to provide an objective and efficient sensor-based mobility assessment that does not require any direct research/clinical oversight.

1 July 2021 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
RSRuopeng Sun
Ruopeng Sun
CTC. Tomkins-Lane
C. Tomkins-Lane
AMA. Muaremi
A. Muaremi
AKA. Kuwabara
A. Kuwabara
MSM. Smuck
M. Smuck