A high level of physical fitness is associated with cardiovascular health in children and adolescents. At present, there is no systematic implementation of a test battery to assess physical fitness at schools in Argentina. The main objective of this study was to implement the ALPHA test battery to determine the physical fitness of a sample made up of Argentine children and adolescents and to establish the proportion of subjects whose aerobic capacity is indicative of future cardiovascular risk. A sample of 1867 participants (967 girls) aged 6 to 19.5 years old assessed using the ALPHA test battery. Four components of physical fitness were measured: 1) morphological component: height, body weight, and waist circumference; 2) musculoskeletal component: standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) cardiorespiratory component: course-navette 20 m, shuttle run test and estimation of maximal oxygen consumption. The 5th, 25th, 50th, 75th, and 95th percentiles were estimated for the main tests. The mean body mass index was 20.8 kg/m2, and 7.8% of participants were classified as obese. In ddition, male participants had a better performance in all physical fitness tests when compared to girls (p< 0.001). An aerobic capacity indicative of cardiovascular risk was observed in 31.6% of all participants. Argentine male children and adolescents included in the sample showed higher levels of physical fitness. Such differences increase with age. Approximately one every three participants had an aerobic capacity indicative of future cardiovascular risk.
11 February 2016 in International Journal of Sports Science & Coaching
This study aimed to describe the influence of four different small-sided games with 15-min duration on physical and physiological demands in rugby union players. Fourteen rugby union players (22.4 ± 3.2 years) participated in the study that was conducted during the competitive period of final-four first Division of 2012–2013 qualifying competition. Time-motion and body impact data were collected using global positional systems technology with heart rate monitored continuously across training sessions. The present study found that interaction between speed zones, impacts zones and small-sided game formats was significant. No differences were found in the distance covered per minute or the interaction of heart rate values; however, players spent the majority of time above 90% of the HRmax. The SSG 1 presents significant lower values in body impacts per minute compared with the other small-sided games. The results of this study demonstrate that small-sided games with evasion skills showed different levels of physical performance, and skill qualities of rugby union players. Although HR responses were similar between all small-sided game formats, the high levels of individual variability may explain the obtained results. Future use of this technology may help practitioners in design and implementation of individual position-specific training programs with appropriate management of player exercise load.
The assessment of VO₂max allow classify subjects according to the health risk. However the factors that may affect the classifications have been little studied. The main purpose was to determine whether the type of VO₂max prediction equation and the Fitnessgram criterion-referenced standards modified the proportion of young adults classified with a level of aerobic capacity cardiometabolic risk indicative. The study design was observational, cross-sectional and relational. Young adults (n= 240) participated voluntarily. The VO₂max was estimated by 20-m shuttle run test applying 9 predictive equations. The differences in the classifications were analyzed with the Cochran Q and McNemar tests. The level of aerobic capacity indicative of cardiometabolic risk ranged between 7.1% and 70.4% depending on the criterion-referenced standards and predictive equation used (p<0.001). A higher percentage of women were classified with an unhealthy level in all equations (women: 29.4% to 85.3% vs 4.8% to 51% in men), regardless of the criterion-referenced standards (p<0.001). Both sexes and irrespective of the equation applied the old criterion-referenced standards classified a lower proportion of subjects (men: 4.8% to 48.1% and women: 39.4% a 68.4%) with unhealthy aerobic capacity (p ≤ 0.004). The type of VO₂max prediction equation and Fitnessgram criterion-referenced standards changed classifications young adults with a level of aerobic capacity of cardiometabolic risk indicative.
1 December 2019 in Archivos Argentinos de Pediatria
Introduction. At present, there is no information about the physical fitness (PF) of children and adolescents attending school in the province of Neuquen. The provincial Department of Sports developed the Physical Fitness Assessment Plan. The main objective of this study was to administer the ALPHA-Fitness test battery to the students of Neuquen in order to develop PF reference standards. Population and methods. A total of 4487 male and female students of Neuquen aged 9-18.9 years were assessed based on four PF components of the high priority ALPHA-Fitness test battery: 1) morphological: body weight and height to estimate body mass index; 2) musculoskeletal: standing long jump test; 3) motor: 4 x 10 m speed/ agility test; and 4) cardiorespiratory: 20-m shuttle run test (SRT). Results. The mean body mass index was 22.9 +/- 4.7 kg/m(2); 25 % of participants were overweight and 12.7 %, obese. The mean values for the cardiorespiratory component were 4.3 +/- 2.5 stages, 10.1 +/- 1.2 km/h, maximal oxygen volume of 38.7 +/- 6.7 mL/kg/min; standing long jump: 147.3 +/- 34.6 cm; and for the motor component: 13.0 +/- 1.5 s. Male participants had a better performance in PF tests (p < 0.001). Conclusion. The study results provide the first PF standards for male and female children and adolescents of the province of Neuquen, Argentina.