Chenyu Zhang

Dr. Chenyu Zhang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
JXJianping ren Xu
Jianping ren Xu
CZChenyu Zhang
Chenyu Zhang
WJWenbo Jin
Wenbo Jin
XLXuemei Luo
Xuemei Luo
ZFZhaoyang Fan
Zhaoyang Fan
FZFan Zhang
Fan Zhang
There are few studies on erosion problems in gas storage environments. High-speed gas-carrying sand in gas storage wells can cause pipeline erosion and subsequent failure. To this end, a numerical model of gas/liquid/solid three-phase erosion under high temperature and high-pressure conditions in gas storage was established. The model combines the laws of conservation of mass, momentum, and energy, as well as the force model of solid particles. Using the established mathematical model of erosion, numerical simulations were performed to study the erosion process of the column under different parameters during gas injection and extraction to find the main factors affecting column erosion. Subsequently, a prediction model was established based on the determined main factors to estimate the maximum erosion rate of the column. The results show that during the extraction process, the maximum erosion rate is exponentially related to the extraction rate, and the erosion intensifies when it is greater than 1 million m3/d. It is linearly related to the particle mass flow rate and the well inclination, and it tends to decrease when the particle size is greater than 3 mm. The erosion law during gas injection is similar to that during extraction, but the erosion during gas injection is more severe. The comprehensive influence of various parameters on the maximum erosion rate was studied by orthogonal experiments, and an erosion prediction model was established by nonlinear regression using the least squares method.

20 January 2025 in Lubricants
Verified
Journal Article
Open access
PDF file
JXJianping ren Xu
Jianping ren Xu
CZChenyu Zhang
Chenyu Zhang
ZFZhaoyang Fan
Zhaoyang Fan
YRYanfei Ren
Yanfei Ren
The objective is to address the issue of gas-carrying particles generated by erosion wear problems in the transportation process of gas storage reservoir pipelines. In accordance with the principles of the multiphase flow theory, the particle discrete phase model, high temperature, high pressure, water volume fraction, and other pertinent factors, this paper presents a three-phase gas–liquid–solid erosion mathematical model of a three-way gas storage reservoir. The effects of temperature, pressure, water content volume fraction, gas extraction, particle mass flow rate, and particle size on the tee’s erosion location and erosion rate were investigated based on this model. The findings indicate that, as the pressure and temperature decline, the maximum erosion rate of the tee exhibits a decreasing trend. Gas storage reservoir water production is relatively low, and its maximum erosion rate of the tee exerts a negligible influence. Conversely, the maximum erosion rate of the tee is significantly influenced by the gas extraction rate, exhibiting an exponential relationship with the maximum erosion rate and the rate of gas extraction. It was observed that, when the volume of gas extracted exceeded 70 × 104 m3/d, the maximum erosion rate of the tee exceeded the critical erosion rate of 0.076 mm/a. The maximum erosion rate of the tee caused by the sand mass flow rate remained relatively constant. However, the maximum erosion rate of the tee exhibited a linear correlation with the salt mass flow rate and the maximum erosion rate. The maximum erosion rate of the tee is greater than the critical erosion rate of 0.076 mm/a when the gas extraction volume is greater than 37.3 × 104 m3/d and the salt mass flow rate is greater than approximately 25 kg/d. As the sand and salt particle sizes increase, the maximum erosion rate of the tee initially rises, then declines, and finally stabilizes. The findings of this study offer valuable insights into the mechanisms governing tee erosion under elevated temperatures and pressures within storage reservoirs.

14 January 2025 in Coatings
Verified
Journal Article
Open access
PDF file
JXJianping ren Xu
Jianping ren Xu
CZChenyu Zhang
Chenyu Zhang
WJWenbo Jin
Wenbo Jin
BHBingyue Han
Bingyue Han
ZFZhaoyang Fan
Zhaoyang Fan
Gas reservoirs play an increasingly important role in oil and gas consumption and safety in China. To study the problem of erosion and wear caused by gas-carrying particles in the process of gas extraction from gas storage reservoirs, a mathematical model of gas–liquid–solid three-phase erosion of gas storage reservoir columns was established through theories of multiphase flow and particle motion. Based on this model, the effects of the water volume fraction, gas extraction rate, particle mass flow rate, particle size, and bending angle on the erosion location and rate of the pipe columns were investigated. The findings indicate that when the water content volume fraction is low, the water production volume minimally affects the maximum erosion rate of pipe columns. Conversely, the gas extraction rate exerted the most significant influence on the column erosion, showing a power function relationship between the two. When gas extraction volume exceeds 60 × 104 m3/d, the maximum erosion rate surpasses the critical erosion rate of 0.076 mm/a. This coincided with the increased sand mass flow rate, although the maximum erosion rate of the pipe columns remained relatively steady. The salt mass flow rate demonstrated a linear relationship with the erosion rate, with the maximum erosion rate exceeding the critical erosion rate of 0.076 mm/a. The maximum erosion rate of the pipe columns increased, stabilized with larger sand and salt particle sizes, and exhibited an increasing trend with the bending angle. For gas extraction volumes exceeding 46.4 × 104 m3/d and salt mass flow rates exceeding 22 kg/d, the maximum erosion rate of pipe columns exceeds the critical erosion rate of 0.076 mm/a. The conclusions of this study are of some importance for the clarification of the influencing law of pipe column erosion under high temperature and high pressure in gas storage reservoirs and for the formulation of measures for the prevention and control of pipe column erosion in gas storage reservoirs.