The paper presents a historical overview of the developments of aerodynamic design methods for low-speed axial-flow fans. This historical overview starts from the first fan applications, dating back to the 16th century, and arrives to the modern times of computer-based design techniques, passing through the pioneering times of aerodynamic theories and the times of designing before computers. The overview shows that the major achievements in the axial fan design discipline have actually been related to other technological fields, such as marine and aeronautical propulsion, as well as to the development of wind tunnels. At the end of the paper, the reader will have acquired a complete panorama of how the historical developments of the discipline have brought us to the current state of the art.
13 January 2016 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Common blade design techniques are based on the assumption of the airflow laying on cylindrical surfaces. This behaviour is proper only for free-vortex flow, whereas radial fluid migration along the span is always present in case of controlled vortex design blades. The paper presents a design procedure to increase aeraulic efficiency of fan rotors originally designed using a controlled vortex criterion, based on the assumption that a blade section positioning taking into account the actual airflow direction could be beneficial for rotor aeraulic performance. The proposed procedure employs a three-dimensional aerofoil positioning and blade forward sweep. The procedure is applied to a rotor-only tube-axial fan featuring a 0.44 hub-to-tip ratio, an almost constant swirl velocity distribution at the rotor outlet and a quite low blade Reynolds number. Rotor prototypes deriving from step-by-step blade modifications are experimentally tested on an ISO 5801 standard test rig. Results show the importance of considering radial fluid migration for highly loaded rotors.
Tube-axial fans are widely used in industrial applications because of their compactness, simplicity, and low cost. However, the achievable fan pressure rise is generally penalised by the absence of a straightener and diffuser, and the consequent waste of tangential and axial dynamic pressures at the fan outlet. The corresponding fan efficiency drop might not comply with stringent regulations like the European Directive for energy-related products. Thus, operation ranges of high efficiency need to be clearly defined in the preliminary design phase, especially when constraints on maximum size and/or rotational speed are imposed. This paper proposes analytical formulas and charts to evaluate the efficiency of the tube-axial fan configuration (with or without tail-cone diffuser) when constraints on fan size and/or speed are additional design requirements. The analytical formulas and charts have been validated against experimental data. On this basis, a preliminary design criterion is suggested for high-efficiency tube-axial fans featuring arbitrary vortex design blades of constant swirl type. The criterion is used to design a 315 mm low-to-medium pressure tube-axial fan that is able to operate at a constant aeraulic efficiency peak of approximately 0.6 for blade positioning angles in the range 20° to 30°.
Both cascade and isolated airfoil methods are considered valid in axial fan blade design, for high (σ≳1) and low (σ≲0.7) solidities respectively. For bladings that feature intermediate solidities the modified isolated approach is commonly employed. This method uses isolated airfoil data, with proper adjustments to take into account multiplane interference effects. Contrarily, the literature does not refer about modifications of the cascade approach to design medium solidity fans. Such method would use cascade data, properly adjusted for the blade sections at lower solidities. Thus, with the aim of comparing these two opposite design approaches (modified cascade versus modified isolated) for medium solidity blades, two free-vortex blading were designed for a 315 mm rotor-only axial fan and experimentally tested. CFD analyses were performed as well to obtain the local flow features. NACA-65 series airfoils were employed, as both cascade and isolated data are available for chord Reynolds numbers typical of axial fans applications. Results highlight the differences between the two approaches. Finally, a mixed approach that employs both isolated and cascade data is suggested as the most accurate one. Moreover, results also show the detrimental effects of the low chord Reynolds numbers on the performance of the blades. This effect should be taken into account in blade design for small-to-medium size machines.