The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT) or, more recently, intraoperative cone-beam CT (CBCT). The ability to register real-time endoscopic video with CBCT offers an additional advantage by rendering information directly within the visual scene to account for intraoperative anatomical change. However, tracker localization error (~1-2 mm ) limits the accuracy with which video and tomographic images can be registered. This paper reports the first implementation of image-based video-CBCT registration, conducts a detailed quantitation of the dependence of registration accuracy on system parameters, and demonstrates improvement in registration accuracy achieved by the image-based approach. Performance was evaluated as a function of parameters intrinsic to the image-based approach, including system geometry, CBCT image quality, and computational runtime. Overall system performance was evaluated in a cadaver study simulating transsphenoidal skull base tumor excision. Results demonstrated significant improvement ( p <; 0.001) in registration accuracy with a mean reprojection distance error of 1.28 mm for the image-based approach versus 1.82 mm for the conventional tracker-based method. Image-based registration was highly robust against CBCT image quality factors of noise and resolution, permitting integration with low-dose intraoperative CBCT.
2 June 2016 in IEEE Transactions on Medical Imaging
Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine.
Percutaneous screw fixation in pelvic trauma surgery is a challenging procedure that often requires long fluoroscopic exposure times and trial-and-error insertion attempts along narrow bone corridors of the pelvis. We report a method to automatically plan surgical trajectories using preoperative CT and assist device placement by augmenting the fluoroscopic scene with planned trajectories. A pelvic shape atlas was formed from 40 CT images and used to construct a statistical shape model (SSM). Each member of the atlas included expert definition of volumetric regions representing safe trajectory within bone corridors for fixating 10 common fracture patterns. Patient-specific planning is obtained by mapping the SSM to the (un-segmented) patient CT via active shape model (ASM) registration and free-form deformation (FFD), and the resulting transformation is used to transfer the atlas trajectory volumes to the patient CT. Fluoroscopic images acquired during K-wire placement are in turn augmented with projection of the planned trajectories via 3D–2D registration. Registration performance was evaluated via leave-one-out cross-validation over the 40-member atlas, computing the root mean square error (RMSE) in pelvic surface alignment (volumetric registration error), the positive predicted value (PPV) of volumetric trajectories within bone corridors (safety of the automatically planned trajectories), and the distance between trajectories within the planned volume and the bone cortex (absence of breach). A cadaver study was conducted in which K-wires were placed under fluoroscopic guidance to validate 3D–2D registration accuracy and evaluate the potential utility of augmented fluoroscopy with planned trajectories. The leave-one-out cross-validation achieved surface RMSE of 2.2 ± 0.3 mm after ASM registration and 1.8 ± 0.2 mm after FFD refinement. Automatically determined surgical plans conformed within bone corridors with PPV > 90% and centerline trajectory within 3–5 mm of the bone cortex. 3D–2D registration in the cadaver study achieved 0.3 ± 0.8 mm accuracy (in-plane translation) and 90% conformance of volumetric planning data overlay within bone, and all centerline trajectories were within safe corridors. The approach yields a method for both automatic planning of pelvic fracture fixation and augmentation of fluoroscopy for improved surgical precision and safety. The method does not require segmentation of the patient CT, operates without additional hardware (e.g. tracking systems), and is consistent with common workflow in fluoroscopically guided procedures. The approach has the potential to reduce operating time and radiation dose by minimizing trial-and-error attempts in percutaneous screw placement.
An algorithm for automatic spinal pedicle screw planning is reported and evaluated in simulation and first clinical studies. A statistical atlas of the lumbar spine ( N = 40 members) was constructed for active shape model (ASM) registration of target vertebrae to an unsegmented patient CT. The atlas was augmented to include ‘reference’ trajectories through the pedicles as defined by a spinal neurosurgeon. Following ASM registration, the trajectories are transformed to the patient CT and accumulated to define a patient-specific screw trajectory, diameter, and length. The algorithm was evaluated in leave-one-out analysis ( N = 40 members) and for the first time in a clinical study ( N = 5 patients undergoing cone-beam CT (CBCT) guided spine surgery), and in simulated low-dose CBCT images. ASM registration achieved (2.0 ± 0.5) mm root-mean-square-error (RMSE) in surface registration in 96% of cases, with outliers owing to limitations in CT image quality (high noise/slice thickness). Trajectory centerlines were conformant to the pedicle in 95% of cases. For all non-breaching trajectories, automatically defined screw diameter and length were similarly conformant to the pedicle and vertebral body (98.7%, Grade A/B). The algorithm performed similarly in CBCT clinical studies (93% centerline and screw conformance) and was consistent at the lowest dose levels tested. Average runtime in planning five-level (lumbar) bilateral screws (ten trajectories) was (312.1 ± 104.0) s. The runtime per level for ASM registration was (41.2 ± 39.9) s, and the runtime per trajectory was (4.1 ± 0.8) s, suggesting a runtime of ~(45.3 ± 39.9) s with a more fully parallelized implementation. The algorithm demonstrated accurate, automatic definition of pedicle screw trajectories, diameter, and length in CT images of the spine without segmentation. The studies support translation to clinical studies in free-hand or robot-assisted spine surgery, quality assurance, and data analytics in which fast trajectory definition is a benefit to workflow.
Metal artifacts present a challenge to cone-beam CT (CBCT) image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy—often in the very region of interest pertinent to the imaging/surgical tasks. We present a method to reduce the influence of metal artifacts by prospectively defining an image acquisition protocol—viz., the C-arm source-detector orbit—that mitigates metal-induced biases in the projection data. The metal artifact avoidance (MAA) method is compatible with simple mobile C-arms, does not require exact prior information on the patient or metal implants, and is consistent with 3D filtered backprojection (FBP), more advanced (e.g. polyenergetic) model-based image reconstruction (MBIR), and metal artifact reduction (MAR) post-processing methods. The MAA method consists of: (i) coarse localization of metal objects in the field-of-view (FOV) via two or more low-dose scout projection views and segmentation (e.g. a simple U-Net) in coarse backprojection; (ii) model-based prediction of metal-induced x-ray spectral shift for all source-detector vertices accessible by the imaging system (e.g. gantry rotation and tilt angles); and (iii) identification of a circular or non-circular orbit that reduces the variation in spectral shift. The method was developed, tested, and evaluated in a series of studies presenting increasing levels of complexity and realism, including digital simulations, phantom experiment, and cadaver experiment in the context of image-guided spine surgery (pedicle screw implants). The MAA method accurately predicted tilted circular and non-circular orbits that reduced the magnitude of metal artifacts in CBCT reconstructions. Realistic distributions of metal instrumentation were successfully localized (0.71 median Dice coefficient) from 2–6 low-dose scout views even in complex anatomical scenes. The MAA-predicted tilted circular orbits reduced root-mean-square error (RMSE) in 3D image reconstructions by 46%–70% and ‘blooming’ artifacts (apparent width of the screw shaft) by 20–45%. Non-circular orbits defined by MAA achieved a further ∼46% reduction in RMSE compared to the best (tilted) circular orbit. The MAA method presents a practical means to predict C-arm orbits that minimize spectral bias from metal instrumentation. Resulting orbits—either simple tilted circular orbits or more complex non-circular orbits that can be executed with a motorized multi-axis C-arm—exhibited substantial reduction of metal artifacts in raw CBCT reconstructions by virtue of higher fidelity projection data, which are in turn compatible with subsequent MAR post-processing and/or polyenergetic MBIR to further reduce artifacts.
9 July 2011 in International Journal of Computer Assisted Radiology and Surgery