To retrospectively evaluate external beam reirradiation (re-EBRT) delivered to the prostate/prostatic bed for local recurrence, after radical or adjuvant/salvage radiotherapy (RT). 32 patients received re-EBRT between February 2008 and October 2013. All patients had clinical/radiological local relapse in the prostate or prostatic bed and no distant metastasis. re-EBRT was delivered with selective RT technologies [stereotactic RT including CyberKnife(TM) (Accuray, Sunnyvale, CA); image-guidance and intensity-modulated RT etc.]. Toxicity was evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Biochemical control was assessed according to the Phoenix definition (NADIR + 2 ng ml(-1)). Acute urinary toxicity: G0, 24 patients; G1, 6 patients; G2, 2 patients. Acute rectal toxicity: G0, 28 patients; G1, 2 patients; and G2, 1 patient. Late urinary toxicity (evaluated in 30 cases): G0, 23 patients; G1, 6 patients; G2, 1 patient. Late renal toxicity: G0, 25 patients; G1, 5 patients. A mean follow-up of 21.3 months after re-EBRT showed that 13 patients were free of cancer, 3 were alive with biochemical relapse and 12 patients were alive with clinically evident disease. Four patients had died: two of disease progression and two of other causes. re-EBRT using modern technology is a feasible approach for local prostate cancer recurrence offering 2-year tumour control in about half of the patients. Toxicity of re-EBRT is low. Future studies are needed to identify the patients who would benefit most from this treatment. Our series, based on experience in one hospital alone, shows that re-EBRT for local relapse of prostate cancer is feasible and offers a 2-year cure in about half of the patients.
1 September 2011 in Urologic Oncology: Seminars and Original Investigations
The purpose of this work was to evaluate the intrapatient tumor position reproducibility in a deep inspiration breath-hold (DIBH) technique based on two infrared optical tracking systems, ExacTrac and ELITETM, in stereotactic treatment of lung and liver lesions. After a feasibility study, the technique was applied to 15 patients. Each patient, provided with a real-time visual feedback of external optical marker displacements, underwent a full DIBH, a free-breathing (FB), and three consecutive DIBH CT-scans centered on the lesion to evaluate the tumor position reproducibility. The mean reproducibility of tumor position during repeated DIBH was in laterolateral (LL), in anteroposterior (AP), and in craniocaudal (CC) direction for lung lesions, and in LL, in AP, and in CC direction for liver lesions. Intra-and interbreath-hold reproducibility during treatment, as determined by optical markers displacements, was below 1 mm and 3 mm, respectively, in all directions for all patients. Optically-guided DIBH technique provides a simple noninvasive method to minimize breathing motion for collaborative patients. For each patient, it is important to ensure that the tumor position is reproducible with respect to the external markers configuration. PACS numbers: 87.53.Ly, 87.55.km
Purpose: The integration of CT and multiparametric MRI (mpMRI) is a challenging task in high-precision radiotherapy for prostate cancer. A simple methodology for multimodal deformable image registration (DIR) of prostate cancer patients is presented. Methods: CT and mpMRI of 10 patients were considered. Organs at risk and prostate were contoured on both scans. The dominant intraprostatic lesion was additionally delineated on MRI. After a preliminary rigid image registration, the voxel intensity of all the segmented structures in both scans except the prostate was increased by a specific amount (a constant additional value, A), in order to enhance the contrast of the main organs influencing its position and shape. 70 couples of scans were obtained by varying A from 0 to 800 and they were subsequently non-rigidly registered. Quantities derived from image analysis and contour statistics were considered for the tuning of the best performing A. Results: A = 200 resulted the minimum enhancement value required to obtain statistically significant superior registration results. Mean centre of mass distance between corresponding structures decreases from 7.4 mm in rigid registration to 5.3 mm in DIR without enhancement (DIR-0) and to 2.7 mm in DIR with A = 200 (DIR-200). Mean contour distance was 2.5, 1.9 and 0.67 mm in rigid registration, DIR-0 and DIR-200, respectively. In DIR-200 mean contours overlap increases of +13 and +24% with respect to DIR-0 and rigid registration, respectively. Conclusion: Contour propagation according to the vector field resulting from DIR-200 allows the delineation of dominant intraprostatic lesion on CT scan and its use for high-precision radiotherapy treatment planning. Advances in knowledge: We investigated the application of a B-spline, mutual information-based multimodal DIR coupled with a simple, patient-unspecific but efficient contrast enhancement procedure in the pelvic body area, thus obtaining a robust and accurate methodology to transfer the functional information deriving from mpMRI onto a planning CT reference volume.
Introduction Of the different treatments for early prostate cancer, hypofractionated external-beam radiotherapy is one of the most interesting and studied options. Methods The main objective of this phase II clinical study is to evaluate the feasibility, in terms of the incidence of acute side effects, of a new ultra-hypofractionated scheme for low- or intermediate-risk prostate cancer patients treated with the latest imaging and radiotherapy technology, allowing dose escalation to the dominant intraprostatic lesion identified by multiparametric magnetic resonance imaging. Secondary endpoints of the study are the evaluation of the long-term tolerability of the treatment in terms of late side effects, quality of life, and efficacy (oncological outcome). Results The study is ongoing, and we expect to complete recruitment by the end of 2016. Conclusions Like in previous studies, we expect ultra-hypofractionated radiation treatment for prostate cancer to be well tolerated and effective. Trial registration ClinicalTrials.gov identifier: NCT01913717.