Jianbo Tian

Dr. Jianbo Tian


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in Construction and Building Materials
Verified
Journal Article
Closed access
DHDaguan Huang
Daguan Huang
YFYing Feng
Ying Feng
QXQian Xia
Qian Xia
JTJianbo Tian
Jianbo Tian
XLXiufei Li
Xiufei Li


26 April 2023 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
JTJianbo Tian
Jianbo Tian
YZYong Zhao
Yong Zhao
PTPenggang Tian
Penggang Tian
WRWengeng Ren
Wengeng Ren
ZLZhe Li
Zhe Li
JLJunlong Lu
Junlong Lu

20 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
JLJunlong Li
Junlong Li
GHGuoqiang He
Guoqiang He
JTJianbo Tian
Jianbo Tian
Due to its high axial bearing capacity and good ductility, the embedded steel plate composite shear wall structure has become one of the most widely used lateral force-resisting structural members in building construction. However, bending failure is prone to occur during strong earthquakes, and the single energy dissipation mechanism of the plastic hinge zone at the bottom leads to the concentration of local wall damage. To improve the embedded steel plate composite shear wall structure, the plastic hinge zone of the composite shear wall is replaced by fiber-reinforced concrete (FRC) and analyzed by ABAQUS finite element simulation analysis. Firstly, the structural model of the embedded steel plate composite shear wall structure with FRC in the plastic hinge zone is established and the accuracy of the model is verified. Secondly, the effects of steel ratio, longitudinal reinforcement ratio, and FRC strength on the bearing capacity of composite shear walls are analyzed by numerical simulation. Finally, a method for calculating the embedded steel plate composite shear wall structure with FRC in the plastic hinge zone is proposed. It is shown that the displacement and load curves and failure modes of the model are basically consistent with the experimental results, and the model has high accuracy. The axial compression ratio and FRC strength have a great influence on the bearing capacity of composite shear walls. The calculation formula of the normal section bending capacity of the embedded steel plate composite shear wall structure with FRC in the plastic hinge zone is proposed. The calculated values of the bending capacity are in good agreement with the simulated values, which can provide a reference for its engineering application.

1 December 2023 in Materials Research Express
Verified
Journal Article
Open access
PDF file
JNJianchun Nie
Jianchun Nie
ZZZhen Zhang
Zhen Zhang
ZZZhen Zhang
Zhen Zhang
YQYufeng Qiao
Yufeng Qiao
ZZZhe Zhao
Zhe Zhao
WZWenjing Zhou
Wenjing Zhou
The coupling beam with small span-to-depth ratio is prone to brittle shear failure under the action of earthquake, so it can not play its role as the first line of defense against earthquake. Therefore, this paper proposes a method for calculating the shear bearing capacity of PRC-connected beams with reinforced truss floor plates. A more rational calculation model should be adopted based on its mechanical mechanism. In this study, ABAQUS finite element software is utilized to explore the parameters of PRC-connected beams with steel truss plates, including the span-to-height ratio, reinforcement ratio of the internal steel plate, diameter of upper and lower chord bars, and diameter of abdominal bars. The analysis shows that the span-to-height ratio, steel plate ratio and concrete compressive strength have a significant effect on the seismic behavior of PRC coupling beams with steel truss floor slab. Based on the softened tension-compression bar model combined with the multi-strip model, the theoretical calculation method of the shear capacity of PRC connected beams with steel truss bearing plates is derived. The results of comparison test and simulation verify the accuracy of the calculation results, and provide a design basis for the engineering application of PRC connected beams with steel truss floor plates.

1 July 2024 in Materials Research Express
Verified
Journal Article
Open access
YXYangyang Xia
Yangyang Xia
CSChenming Shen
Chenming Shen
YXYuanyuan Xia
Yuanyuan Xia
HYHaizeng Yang
Haizeng Yang
YWYouchun Wang
Youchun Wang
JTJianbo Tian
Jianbo Tian
This paper based on the study of steel plate-fiber reinforced concrete coupling beam components, designs a basic model of composite coupled shear walls with steel plate-fiber reinforced concrete coupling beams. The seismic performance of this model was numerically simulated using the ABAQUS finite element software, analyzing the stress distribution of various parts and the development pattern of plastic hinges in the structure. It also examines how factors such as axial compression ratio, coupling beam cross-sectional dimensions, single-sided wall limb aspect ratio, and total floor height affect the seismic performance of this type of coupled shear wall, providing a reasonable range for axial compression ratios and coupling ratios for composite coupled shear walls with steel plate-fiber reinforced concrete coupling beams. Based on the obtained reasonable axial compression ratio and coupling ratio, and using the analytical solution of the continuum method, a method for controlling the seismic performance of coupled shear wall structures was proposed. Results show that the composite coupled shear walls with steel plate-fiber reinforced concrete coupling beams exhibit high load-bearing capacity and lateral stiffness under inverted triangular horizontal loads, with good displacement ductility and strong energy dissipation capability, making it an excellent seismic performance coupled shear wall system. As the axial compression ratio increases, the displacement corresponding to the yield point and peak point of the structure gradually decreases, and the displacement ductility coefficient shows a trend of first increasing and then decreasing; it is recommended that when designing steel plate-fiber reinforced concrete coupling beam-coupled shear walls, the axial compression ratio should not exceed 0.3. Numerical analysis of coupling ratio-related parameters indicates that in high-intensity seismic design areas, the range of coupling ratios should be between 45% and 60%.