Thermal bridges significantly affect the thermal performance of light steel framing systems due to the high thermal conductivity of steel. The objective of this study is to identify modifications on the steel profiles to reduce heat flux and improve the thermal resistance of both single- and double-layer wall panels. Three approaches were analyzed: (i) slotted steel studs, (ii) integration of less-conductive materials into the web section, and (iii) modifications to web geometry. A numerical model was calibrated based on experimental data and used to perform dynamic simulations with different configurations. Results show that incorporating less-conductive materials, such as rigid polyamide, achieved a heat flux reduction of up to 98%, while optimized slotted patterns reduced heat flux by up to 90%. The results also demonstrated that all web modifications effectively reduced heat flux through the wall, with approaches (i) and (ii) showing the greatest impact. The shape of the slots also has an important impact on the heat flux. The most effective strategy for enhancing the thermal performance of the steel studs was the use of a less-conductive material.
Excessive energy consumption in the building sector and its associated environmental impacts underscore the urgent need for more effective passive control strategies. This study evaluates the performance of adaptive shading systems on buildings thermal comfort and energy demand through dynamic simulations of a test cell located in Aveiro, Portugal. Simulations were conducted in EnergyPlus and parametrically implemented via the Grasshopper plugin for Rhinoceros 3D. Four scenarios were analysed: no shading, fixed shading systems, manually operated shading systems and automated adaptive shading systems, considering shading blades angles ranging from –30° to +30°. Results indicate that fixed shading improved thermal comfort by up to 8.1%, while manual systems operation achieved by up to 9.5% and adaptive systems demonstrated the best performance, with gains of up to 9.5%. The adaptative system outperformed all other configurations, increasing thermal comfort by up to 16.2% and reducing cooling demand by 14.3% relative to unshaded baseline. These findings provide quantitative evidence that adaptive shading devices are an effective strategy for enhancing building thermal performance and reducing energy use, reinforcing their relevance for high performance, climate responsive design in the built environment.
Sealed vertical air cavities are important thermal components in lightweight multilayer building envelopes, with resistance governed by natural convection and long-wave surface-to-surface radiation. Improvement has relied mainly on low-emissivity surfaces, whereas air-cushion filling remains insufficiently understood. This study experimentally assessed air-cushion filling as an internal layer in a sealed 200 mm vertical cavity. Hot-box tests evaluated four configurations combining high- and low-emissivity surfaces, with and without air-cushion filling. The same performance ranking occurred under all boundary-condition scenarios: high-emissivity empty cavity < low-emissivity empty cavity < high-emissivity cavity with air-cushion filling < low-emissivity cavity with air-cushion filling. Cavity thermal resistance ranged from 0.18–0.23 m²·K/W for high-emissivity empty cavities to 1.01–1.10 m²·K/W for low-emissivity cavities with air-cushion filling. Relative to the corresponding empty cavity, filling increased resistance to 3.95–4.33 times the baseline under high-emissivity conditions and to 1.70–1.75 times under low-emissivity conditions. This demonstrates an additional experimental gain after low-emissivity treatment, although the filled-cavity mechanism remains unresolved. A three-dimensional CFD model, validated only for empty cavities, reproduced experimental resistance within the adopted 5% threshold and provided an interpretive framework for the baseline heat-transfer regime. Air-cushion filling is therefore a relevant design variable for the tested assembly, supporting joint evaluation of internal cavity architecture and surface emissivity.