Xianghui Wang

Xianghui Wang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2019 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
YLYuquan Li
Yuquan Li
BNBin Ni
Bin Ni
XLXiaodan Li
Xiaodan Li
XWXianghui Wang
Xianghui Wang
DZDafeng Zhang
Dafeng Zhang
Likun PanLikun Pan
Likun Pan
Na-ion batteries (NIBs) have attracted considerable attention in recent years owing to the high abundance and low cost of Na. It is well known that S doping can improve the electrochemical performance of carbon materials for NIBs. However, the current methods for S doping in carbons normally involve toxic precursors or rigorous conditions. In this work, we report a creative and facile strategy for preparing S-doped porous carbons (SCs) via the pyrolysis of conjugated microporous polymers (CMPs). Briefly, thiophene-based CMPs served as the precursors and doping sources simultaneously. Simple direct carbonization of CMPs produced S-doped carbon materials with highly porous structures. When used as an anode for NIBs, the SCs exhibited a high reversible capacity of 440 mAh g−1 at 50 mA g−1 after 100 cycles, superior rate capability, and excellent cycling stability (297 mAh g−1 after 1000 cycles at 500 mA g−1), outperforming most S-doped carbon materials reported thus far. The excellent performance of the SCs is attributed to the expanded lattice distance after S doping. Furthermore, we employed ex situ X-ray photoelectron spectroscopy to investigate the electrochemical reaction mechanism of the SCs during sodiation–desodiation, which can highlight the role of doped S for Na-ion storage.

28 January 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
HHHailong Huang
Hailong Huang
HGHao Ge
Hao Ge
ZRZhipeng Ren
Zhipeng Ren
ZHZhijian Huang
Zhijian Huang
MXMin Xu
Min Xu
XWXianghui Wang
Xianghui Wang
Heavy metal ions overload can seriously harm human health. Simple and effective strategies for the specific detection of heavy metal ions are of great important. In this work, using different pretreatment methods, a series of carbon dots (CDs) with different particle sizes and doped with varying amounts of elements (O, N, S) were prepared based on the natural polymer, cellulose hydrogel. The CDs exhibit excellent fluorescence and biocompatibility. When the particle size decreased from 8.72 to 2.11 nm, the fluorescence quantum yield increased from 0.029 to 0.183. In addition, doping with elements (N) also effectively enhanced the fluorescent performance of the CDs. The fluorescence of the CDs, especially for the smallest, CD-4a, was significantly quenched in the presence of the heavy metal ion, Hg2+. Thus, CD-4a may be used as a fluorescence sensor for the detection of Hg2+. The fluorescence intensity of CD-4a exhibited a two-stage, concentration-dependent fluorescence response in the range 0.2–10 and 10–100 μmol/L Hg2+, with each stage having different slopes; the detection limit was 0.2 μM. More importantly, even in the presence of interfering metal ions, the detection of Hg2+ using the CDs-4a remained stable. Therefore, these biocompatible CDs may serve as a promising candidate for the specific detection of Hg2+.

1 April 2020 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
HYHuangze Yu
Huangze Yu
JLJunfeng Li
Junfeng Li
GGGuoliang Gao
Guoliang Gao
GZGuang Zhu
Guang Zhu
XWXianghui Wang
Xianghui Wang
Likun PanLikun Pan
Likun Pan

1 July 2019 in Inorganic Chemistry Frontiers
Verified
Journal Article
Closed access
PDF file
JLJunfeng Li
Junfeng Li
LHLu Han
Lu Han
DZDafeng Zhang
Dafeng Zhang
JLJinliang Li
Jinliang Li
TLTing Lu
Ting Lu
Likun PanLikun Pan
Likun Pan
Pseudocapacitance, typically occurring on the surface of the electrode material, plays a crucial role in improving the charge/discharge rate of sodium ion batteries (SIBs). In this work, N, S co-doped porous carbon microtubes (SNCTs) are prepared through modified in situ polymerization and subsequent annealing with sublimed sulphur in a nitrogen atmosphere. The one-dimensional porous hollow structure enhances the electrolyte penetration and shortens the sodium-ion diffusion pathway, while the N, S doping improves the electrical conductivity of carbon and offers excess reaction sites for sodium-ion storage. The electrode reactions are dominated by a pseudocapacitive process, which can effectively shorten the sodium-ion diffusion pathway and provide extra capacity, resulting in high-rate capability. When used as anodes for SIBs, SNCTs demonstrate good cycling stability (222 mA h g−1 at 2000 mA g−1 after 800 cycles) and superior rate performance (288 and 252 mA h g−1 at 1000 and 2000 mA g−1, respectively). A room-temperature full cell SIB is further assembled using the SNCT as the anode and commercial Na3V2(PO4)3 as the cathode, which exhibits a high specific capacity of 186.1 mA h g−1 after 50 cycles at 50 mA g−1. This work should provide new insights into carbon-based anode materials as high-performance anodes for SIBs.

Verified
Journal Article
Open access
PDF file
PXPang Xiaofeng
Pang Xiaofeng
SCShude Chen
Shude Chen
XWXianghui Wang
Xianghui Wang
LZLisheng Zhong
Lisheng Zhong
The influences of electromagnetic fields (EMFs) on bio-energy transport and its mechanism of changes are investigated through analytic and numerical simulation and experimentation. Bio-energy transport along protein molecules is performed by soliton movement caused by the dipole–dipole electric interactions between neighboring amino acid residues. As such, EMFs can affect the structure of protein molecules and change the properties of the bio-energy transported in living systems. This mechanism of biological effect from EMFs involves the amino acid residues in protein molecules. To study and reveal this mechanism, we simulated numerically the features of the movement of solitons along protein molecules with both a single chain and with three channels by using the Runge–Kutta method and Pang’s soliton model under the action of EMFs with the strengths of 25,500, 51,000, 76,500, and 102,000 V/m in the single-chain protein, as well as 17,000, 25,500, and 34,000 V/m in the three-chain protein, respectively. Results indicate that electric fields (EFs) depress the binding energy of the soliton, decrease its amplitude, and change its wave form. Also, the soliton disperses at 102,000 V/m in a single-chain protein and at 25,500 and 34,000 V/m in three-chain proteins. These findings signify that the influence of EMFs on the bio-energy transport cannot be neglected; however, these variations depend on both the strength and the direction of the EF in the EMF. This direction influences the biological effects of EMF, which decrease with increases in the angle between the direction of the EF and that of the dipole moment of amino acid residues; however, randomness at the macroscopic level remains. Lastly, we experimentally confirm the existence of a soliton and the validity of our conclusion by using the infrared spectra of absorption of the collagens, which is activated by another type of EF. Thus, we can affirm that both the described mechanism and the corresponding theory are correct and that EMFs or EFs can influence the features of energy transport in living systems and thus have certain biological effects.

1 January 2020 in REVIEWS ON ADVANCED MATERIALS SCIENCE
Verified
Journal Article
Open access
PDF file
AZZAM AHMEDAZZAM AHMED
AZZAM AHMED
XWXianghui Wang
Xianghui Wang
MYMing Yang
Ming Yang
The biomedical materials that have been used in the structure of heart pumps are classified as biocompatible, and these can be metals, polymers, ceramics, and composites. Their positions in the pump vary according to the part’s function. Whereas various materials have different properties, all biomaterials chosen for cardiovascular applications should have excellent blood biocompatibility to reduce the likelihood of hemolysis and thrombosis. There are two major categories of the heart pumps; pulsatile and rotary blood pumps (axial and centrifugal) and the features of some of these materials allow them to be used in both. Rotary and pulsatile blood pump devices have to be fabricated from materials that do not result in adverse biological responses. The purpose of this review is to study the available biocompatible materials for the pulsatile and rotary blood pumps as clinically-approved materials and prototype heart pump materials. The current state of bio-compatible materials of rotary and pulsatile blood pump construction is presented. Some recent applications of surface amendment technology on the materials for heart assist devices were also reviewed for better understanding. The limitations of heart assist devices, and the future direction of artificial heart elements have been considered. This review will be considered as a comprehensive reference to rapidly understanding the necessary research in the field of biocompatible materials of pulsatile and blood rotary pumps.