Nathan Hagen

Dr. Nathan Hagen

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Optical Engineering
Verified
Journal Article
Open access
PDF file
NHNathan Hagen
Nathan Hagen
MKMichael W. Kudenov
Michael W. Kudenov
Within the field of spectral imaging, the vast majority of instruments used are scanning devices. Recently, several snapshot spectral imaging systems have become commercially available, providing new functionality for users and opening up the field to a wide array of new applications. A comprehensive survey of the available snapshot technologies is provided, and an attempt has been made to show how the new capabilities of snapshot approaches can be fully utilized.

21 June 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
LGLiang Gao
Liang Gao
RKRobert T. Kester
Robert T. Kester
NHNathan Hagen
Nathan Hagen
TTTomasz S. Tkaczyk
Tomasz S. Tkaczyk
A snapshot Image Mapping Spectrometer (IMS) with high sampling density is developed for hyperspectral microscopy, measuring a datacube of dimensions 285 × 285 × 60 (x, y, λ). The spatial resolution is ~0.45 µm with a FOV of 100 × 100 µm2. The measured spectrum is from 450 nm to 650 nm and is sampled by 60 spectral channels with average sampling interval ~3.3 nm. The channel’s spectral resolution is ~8nm. The spectral imaging results demonstrate the potential of the IMS for real-time cellular fluorescence imaging.

10 June 2009 in Optics Express
Verified
Journal Article
Open access
PDF file
DBDavid J. Brady
David J. Brady
NHNathan Hagen
Nathan Hagen
While lenses of aperture less than 1000λ frequently form images with pixel counts approaching the space-bandwidth limit, only heroic designs approach the theoretical information capacity at larger scales. We propose to use the field processing capabilities of small-scale secondary lens arrays to correct aberrations due to larger scale objective lenses, with an ultimate goal of achieving diffraction-limited imaging for apertures greater than 10,000λ. We present an example optical design using an 8 mm entrance pupil capable of resolving 20 megapixels.

13 June 2012 in Optical Engineering
Verified
Journal Article
Open access
PDF file
NHNathan Hagen
Nathan Hagen
LGLiang S. Gao
Liang S. Gao
TTTomasz S. Tkaczyk
Tomasz S. Tkaczyk
RKRobert T. Kester
Robert T. Kester
Imaging spectrometers collect data over three dimensions—two spatial (x,y) and one spectral (λ)—so that the complete (x,y,λ) dataset is typically referred to as a datacube. The most common method for categorizing the various types of imaging spectrometers is by the portion of the datacube collected in a single detector readout. “Whiskbroom” spectrometers, which use a linear array of detectors, collect a single column of the datacube at a time and thus scan across the two spatial dimensions of the datacube (see Fig. 1).1 “Pushbroom” spectrometers use a 2D detector array, and thus collect a vertical slice of the datacube at once so that only one spatial dimension needs to be scanned to fill out the cube.2 A filtered camera, constructed by placing a filter wheel or tunable spectral filter in front of a camera, collects a horizontal slice and thus needs to scan along the spectral dimension to complete the data set.3 Other scanning modalities exist, such as Fourier Transform imaging spectrometry (FTIS), but these can be shown4,5 as equivalent to one of the above categories—in this case, the filtered camera.

1 January 2007 in Optics Express
Verified
Journal Article
Closed access
PDF file
MKMichael W. Kudenov
Michael W. Kudenov
NHNathan Hagen
Nathan Hagen
EDEustace L. Dereniak
Eustace L. Dereniak
GGGrant R. Gerhart
Grant R. Gerhart
A complete Fourier Transform Spectropolarimeter in the MWIR is demonstrated. The channeled spectral technique, originally developed by K. Oka, is implemented with the use of two Yttrium Vanadate (YVO4) crystal retarders. A basic mathematical model for the system is presented, showing that all the Stokes parameters are directly present in the interferogram. Theoretical results are compared with real data from the system, an improved model is provided to simulate the effects of absorption within the crystal, and a modified calibration technique is introduced to account for this absorption. Lastly, effects due to interferometer instabilities on the reconstructions, including nonuniform sampling and interferogram translations, are investigated and techniques are employed to mitigate them.

12 April 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MKMichael W. Kudenov
Michael W. Kudenov
MEMichael J. Escuti
Michael J. Escuti
NHNathan Hagen
Nathan Hagen
EDEustace L. Dereniak
Eustace L. Dereniak
KOKazuhiko Oka
Kazuhiko Oka
A snapshot imaging Mueller matrix polarimeter (SIMMP) is theoretically described and empirically demonstrated through simulation. Spatial polarization fringes are localized onto a sample by incorporating polarization gratings (PGs) into a polarization generator module. These fringes modulate the Mueller matrix (MM) components of the sample, which are subsequently isolated with PGs in an analyzer module. The MM components are amplitude modulated onto spatial carrier frequencies which, due to the PGs, maintain high visibility in spectrally broadband illumination. An interference model of the SIMMP is provided, followed by methods of reconstruction and calibration. Lastly, a numerical simulation is used to demonstrate the system’s performance in the presence of noise.