Within the field of spectral imaging, the vast majority of instruments used are scanning devices. Recently, several snapshot spectral imaging systems have become commercially available, providing new functionality for users and opening up the field to a wide array of new applications. A comprehensive survey of the available snapshot technologies is provided, and an attempt has been made to show how the new capabilities of snapshot approaches can be fully utilized.
A snapshot Image Mapping Spectrometer (IMS) with high sampling density is developed for hyperspectral microscopy, measuring a datacube of dimensions 285 × 285 × 60 (x, y, λ). The spatial resolution is ~0.45 µm with a FOV of 100 × 100 µm2. The measured spectrum is from 450 nm to 650 nm and is sampled by 60 spectral channels with average sampling interval ~3.3 nm. The channel’s spectral resolution is ~8nm. The spectral imaging results demonstrate the potential of the IMS for real-time cellular fluorescence imaging.
While lenses of aperture less than 1000λ frequently form images with pixel counts approaching the space-bandwidth limit, only heroic designs approach the theoretical information capacity at larger scales. We propose to use the field processing capabilities of small-scale secondary lens arrays to correct aberrations due to larger scale objective lenses, with an ultimate goal of achieving diffraction-limited imaging for apertures greater than 10,000λ. We present an example optical design using an 8 mm entrance pupil capable of resolving 20 megapixels.
Imaging spectrometers collect data over three dimensions—two spatial and one spectral —so that the complete dataset is typically referred to as a datacube. The most common method for categorizing the various types of imaging spectrometers is by the portion of the datacube collected in a single detector readout. “Whiskbroom” spectrometers, which use a linear array of detectors, collect a single column of the datacube at a time and thus scan across the two spatial dimensions of the datacube (see Fig. 1).1 “Pushbroom” spectrometers use a 2D detector array, and thus collect a vertical slice of the datacube at once so that only one spatial dimension needs to be scanned to fill out the cube.2 A filtered camera, constructed by placing a filter wheel or tunable spectral filter in front of a camera, collects a horizontal slice and thus needs to scan along the spectral dimension to complete the data set.3 Other scanning modalities exist, such as Fourier Transform imaging spectrometry (FTIS), but these can be shown4,5 as equivalent to one of the above categories—in this case, the filtered camera.
A complete Fourier Transform Spectropolarimeter in the MWIR is demonstrated. The channeled spectral technique, originally developed by K. Oka, is implemented with the use of two Yttrium Vanadate (YVO4) crystal retarders. A basic mathematical model for the system is presented, showing that all the Stokes parameters are directly present in the interferogram. Theoretical results are compared with real data from the system, an improved model is provided to simulate the effects of absorption within the crystal, and a modified calibration technique is introduced to account for this absorption. Lastly, effects due to interferometer instabilities on the reconstructions, including nonuniform sampling and interferogram translations, are investigated and techniques are employed to mitigate them.
A snapshot imaging Mueller matrix polarimeter (SIMMP) is theoretically described and empirically demonstrated through simulation. Spatial polarization fringes are localized onto a sample by incorporating polarization gratings (PGs) into a polarization generator module. These fringes modulate the Mueller matrix (MM) components of the sample, which are subsequently isolated with PGs in an analyzer module. The MM components are amplitude modulated onto spatial carrier frequencies which, due to the PGs, maintain high visibility in spectrally broadband illumination. An interference model of the SIMMP is provided, followed by methods of reconstruction and calibration. Lastly, a numerical simulation is used to demonstrate the system’s performance in the presence of noise.