Valérie Desauziers

Prof. Valérie Desauziers


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2013 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
DBDelphine Bourdin
Delphine Bourdin
VDValérie Desauziers
Valérie Desauziers

1 August 2014 in Toxicology Letters
Verified
Journal Article
Closed access
GBGaëlle Bardet
Gaëlle Bardet
SASophie Achard
Sophie Achard
TLThomas Loret
Thomas Loret
VDValérie Desauziers
Valérie Desauziers
IMIsabelle Momas
Isabelle Momas
NSNathalie Seta
Nathalie Seta

7 March 2017 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MGMylène Ghislain
Mylène Ghislain
JBJoana Beigbeder
Joana Beigbeder
HPHervé Plaisance
Hervé Plaisance
VDValérie Desauziers
Valérie Desauziers

20 September 2016 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
MGMylène Ghislain
Mylène Ghislain
JBJoana Beigbeder
Joana Beigbeder
LDLoïc Dumazert
Loïc Dumazert
JLJosé-Marie Lopez-Cuesta
José-Marie Lopez-Cuesta
MLMohammed Lounis
Mohammed Lounis
VDValérie Desauziers
Valérie Desauziers

9 June 2015 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
JVJane Vignau-Laulhere
Jane Vignau-Laulhere
HPHervé Plaisance
Hervé Plaisance
PMPierre Mocho
Pierre Mocho
KRKatarzyna Raulin
Katarzyna Raulin
YBYves Bigay
Yves Bigay
VDValérie Desauziers
Valérie Desauziers
The radial diffusive standard sampler Radiello® filled with Florisil impregnated with 2,4-dinitrophenylhydrazine (DNPH) was evaluated with the goal of survey monitoring the formaldehyde concentration in indoor air for a 4.5 day sampling time. A Radiello® sampler provides measurements with a relative standard deviation of repeatability comprised between 1.5 and 4.0%, a high sampling rate assessed to 98.7 ± 2.8 mL min−1 under standard conditions (temperature: 19.9 ± 0.5 °C and relative humidity: 52.9 ± 3.2%) and a detection limit of 0.5 μg m−3 for a 4.5 day sampling time. The influence of three environmental factors (temperature (T°), relative humidity (RH) and ozone concentration (O3)) on the sampling rate was also evaluated in an exposure chamber following a fractional design of the experiment at two factor levels (low and high). Temperature is found to be the factor leading to the most significant variation of the sampling rate with an effect of +1.8% per °C. From the fractional design of the experiment, a model was set up for expressing the sample rate of Radiello® as a function of significant factors and the uncertainty on the sampling rate was assessed to 11.9% under the domain of tested conditions.

12 March 2011 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
PMPierre Mocho
Pierre Mocho
VDValérie Desauziers
Valérie Desauziers