On 3 November 2021, an interplanetary coronal mass ejection impacted the Earth’s magnetosphere leading to a relevant geomagnetic storm (Kp = 8-), the most intense event that occurred so far during the rising phase of solar cycle 25. This work presents the state of the solar wind before and during the geomagnetic storm, as well as the response of the plasmasphere–ionosphere–thermosphere system in the European sector. To investigate the longitudinal differences, the ionosphere–thermosphere response of the American sector was also analyzed. The plasmasphere dynamics was investigated through field line resonances detected at the European quasi-Meridional Magnetometer Array, while the ionosphere was investigated through the combined use of ionospheric parameters (mainly the critical frequency of the F2 layer, foF2) from ionosondes and Total Electron Content (TEC) obtained from Global Navigation Satellite System receivers at four locations in the European sector, and at three locations in the American one. An original method was used to retrieve aeronomic parameters from observed electron concentration in the ionospheric F region. During the analyzed interval, the plasmasphere, originally in a state of saturation, was eroded up to two Earth’s radii, and only partially recovered after the main phase of the storm. The possible formation of a drainage plume is also observed. We observed variations in the ionospheric parameters with negative and positive phase and reported longitudinal and latitudinal dependence of storm features in the European sector. The relative behavior between foF2 and TEC data is also discussed in order to speculate about the possible role of the topside ionosphere and plasmasphere response at the investigated European site. The American sector analysis revealed negative storm signatures in electron concentration at the F2 region. Neutral composition and temperature changes are shown to be the main reason for the observed decrease of electron concentration in the American sector.
Vertical ionospheric soundings have been performed at almost all ionospheric observatories with little attention to measuring the attenuation of the signal between transmission and reception. When the absorption has been determined, this has been achieved by comparing the received power after the first and second reflections, but this method has some limitations due to the unknown reflection coefficient of the ground and the non-continuous presence of the second reflection. This paper deals with a different method based on precise calibration of the sounding system, allowing determination of absolute signal attenuation after a single reflection. This approach is affected by a systematic error due to imperfect calibration of the antennas, but when the focus of interest is to measure a trend over a specified period, it is very accurate. The article describes how calibration was implemented, the measurement output formats, and finally it presents some results from a meaningful set of measurements in order to demonstrate what this method can accomplish.
For the bedrock survey in the temperate glacier regions, low frequency antenna system of the airborne ground penetrating RADAR plays a very important role. A small size antenna, working at 10 MHz, would make its use easier in various radar applications. Reducing the resonant frequency of the wire dipole antenna structure, without increasing the physical size, can be attained by introducing bents in the existing structure. This paper introduces a new bent wire dipole antenna and presents the effects of bent angle of 80°, 70°, 60°, 50°, 45° and 40°of the wire antenna on the antenna parameters such as resonant frequency, S11, VSWR, gain and radiation pattern. A broadband four element equivalent circuit model of a straight dipole is used with some modifications in the R, L, C equations for the new bent wire dipole antenna by utilizing the bent angle. The frequency response of the equivalent circuit model, calculated resonant frequency values using the equations and the simulated results of the bent wire dipole antenna is compared and analyzed. As the antenna placement area inside the anechoic chamber is limited, the size of the 10MHz antenna has been scaled down by a factor of 0.01. This modifies the resonant frequency of the new structure to 1GHz. The scaled down antenna system are simulated, analyzed and tested in a GTEM cell. For bandwidth improvement of the 10 MHz antenna, a lumped element matching circuit has been designed and simulated.