Florent Tixier

Dr. Florent Tixier

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
HUHyemin Um
Hyemin Um
FTFlorent Tixier
Florent Tixier
DBDalton Bermudez
Dalton Bermudez
JDJoseph O Deasy
Joseph O Deasy
RYRobert J Young
Robert J Young
HVHarini Veeraraghavan
Harini Veeraraghavan
Recent advances in radiomics have enhanced the value of medical imaging in various aspects of clinical practice, but a crucial component that remains to be investigated further is the robustness of quantitative features to imaging variations and across multiple institutions. In the case of MRI, signal intensity values vary according to the acquisition parameters used, yet no consensus exists on which preprocessing techniques are favorable in reducing scanner-dependent variability of image-based features. Hence, the purpose of this study was to assess the impact of common image preprocessing methods on the scanner dependence of MRI radiomic features in multi-institutional glioblastoma multiforme (GBM) datasets. Two independent GBM cohorts were analyzed: 50 cases from the TCGA-GBM dataset and 111 cases acquired in our institution, and each case consisted of 3 MRI sequences viz. FLAIR, T1-weighted, and T1-weighted post-contrast. Five image preprocessing techniques were examined: 8-bit global rescaling, 8-bit local rescaling, bias field correction, histogram standardization, and isotropic resampling. A total of 420 features divided into eight categories representing texture, shape, edge, and intensity histogram were extracted. Two distinct imaging parameters were considered: scanner manufacturer and scanner magnetic field strength. Wilcoxon tests identified features robust to the considered acquisition parameters under the selected image preprocessing techniques. A machine learning-based strategy was implemented to measure the covariate shift between the analyzed datasets using features computed using the aforementioned preprocessing methods. Finally, radiomic scores (rad-scores) were constructed by identifying features relevant to patients’ overall survival after eliminating those impacted by scanner variability. These were then evaluated for their prognostic significance through Kaplan–Meier and Cox hazards regression analyses. Our results demonstrate that overall, histogram standardization contributes the most in reducing radiomic feature variability as it is the technique to reduce the covariate shift for three feature categories and successfully discriminate patients into groups of different survival risks.

14 September 2024 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
FLFelipe Lopez-Ramirez
Felipe Lopez-Ramirez
SSSahar Soleimani
Sahar Soleimani
JAJavad R. Azadi
Javad R. Azadi
SSSheila Sheth
Sheila Sheth
SKSatomi Kawamoto
Satomi Kawamoto
LCLinda C. Chu
Linda C. Chu

28 February 2025 in Seminars in Nuclear Medicine
Verified
Journal Article
Closed access
FLFelipe Lopez-Ramirez
Felipe Lopez-Ramirez
MYMohammad Yasrab
Mohammad Yasrab
FTFlorent Tixier
Florent Tixier
SKSatomi Kawamoto
Satomi Kawamoto
EFEliot Keith Fishman
Eliot Keith Fishman
LCLinda C. Chu
Linda C. Chu

19 August 2025 in Radiology Advances
Verified
Journal Article
Open access
FLFelipe Lopez-Ramirez
Felipe Lopez-Ramirez
ESEmir Amaro Syailendra
Emir Amaro Syailendra
FTFlorent Tixier
Florent Tixier
SKSatomi Kawamoto
Satomi Kawamoto
EFEliot Keith Fishman
Eliot Keith Fishman
LCLinda C. Chu
Linda C. Chu
Advancements in artificial intelligence (AI) are transforming medical imaging diagnostics, offering new possibilities for automated pancreatic tumor detection in computed tomography scans. Pancreatic ductal adenocarcinoma continues to be one of the most lethal malignancies, with early detection being critical for improving survival rates. Deep learning models can learn hierarchical feature representations directly from imaging data, enhancing tumor detection accuracy. However, variations in model performance, impaired generalizability, and limited interpretability remain critical barriers to clinical adoption. This article provides a comprehensive overview of deep learning-based pancreatic tumor detection, discussing fundamental concepts, recent advancements, and challenges for clinical adoption. Implementation of deep learning tumor detection models into imaging workflows holds promise for improving early detection rates of pancreatic tumors. Addressing issues of standardization, external validation, and model transparency will be essential to enable the integration of AI into pancreatic cancer screening and diagnostics, ultimately improving early detection and patient outcomes.

20 March 2025 in Cancers
Verified
Journal Article
Open access
PDF file
FTFlorent Tixier
Florent Tixier
FLFelipe Lopez-Ramirez
Felipe Lopez-Ramirez
ABAlejandra Blanco
Alejandra Blanco
Ammar Asrar JavedAmmar Asrar Javed
Ammar Asrar Javed
LCLinda C. Chu
Linda C. Chu
SKSatomi Kawamoto
Satomi Kawamoto
Background/Objectives: Accurate identification of grade 1 (G1) pancreatic neuroendocrine tumors (PanNETs) is crucial due to their rising incidence and emerging nonsurgical management strategies. This study evaluated whether combining conventional CT imaging features, CT radiomics features, and clinical data improves differentiation of G1 PanNETs from higher-grade tumors (G2/G3 PanNETs and pancreatic neuroendocrine carcinomas [PanNECs]) compared to using these features individually. Methods: A retrospective analysis included 133 patients with pathologically confirmed PanNETs or PanNECs (70 males, 63 females; mean age, 58.5 years) who underwent pancreas protocol CT. A total of 28 conventional imaging features, 4892 radiomics features, and clinical data (age, gender, and tumor location) were analyzed using a support vector machine (SVM) model. Data were divided into 70% training and 30% testing sets. Results: The SVM model using the top 10 conventional imaging features (e.g., suspicious lymph nodes and hypoattenuating tumors) achieved 75% sensitivity, 81% specificity, and 79% accuracy for identifying higher-grade tumors (G2/G3 PanNETs and PanNECs). The top 10 radiomics features yielded 94% sensitivity, 46% specificity, and 69% accuracy. Combining all features (imaging, radiomics, and clinical data) improved performance, with 94% sensitivity, 69% specificity, 79% accuracy, and an F1-score of 0.77. The radiomics score demonstrated an AUC of 0.85 in the training and 0.83 in the testing set. Conclusions: Conventional imaging features provided higher specificity, while radiomics offered greater sensitivity for identifying higher-grade tumors. Integrating all three features improved diagnostic accuracy, highlighting their complementary roles. This combined model may serve as a valuable tool for distinguishing higher-grade tumors from G1 PanNETs and potentially guiding patient management.

16 January 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
FTFlorent Tixier
Florent Tixier
FLFelipe Lopez-Ramirez
Felipe Lopez-Ramirez
ABAlejandra Blanco
Alejandra Blanco
MYMohammad Yasrab
Mohammad Yasrab
Ammar Asrar JavedAmmar Asrar Javed
Ammar Asrar Javed
SKSatomi Kawamoto
Satomi Kawamoto
The WHO grading of pancreatic neuroendocrine neoplasms (PanNENs) is essential in patient management and an independent prognostic factor for patient survival. Radiomics features from CE-CT images hold promise for the outcome and tumor grade prediction. However, variations in reconstruction parameters can impact the predictive value of radiomics. 127 patients with histopathologically confirmed PanNENs underwent CT scans with filtered back projection (B20f) and iterative (I26f) reconstruction kernels. 3190 radiomic features were extracted from tumors and pancreatic volumes. Wilcoxon paired tests assessed the impact of reconstruction kernels and ComBat harmonization efficiency. SVM models were employed to predict tumor grade using the entire set of radiomics features or only those identified as harmonizable. The models’ performance was assessed on an independent dataset of 36 patients. Significant differences, after correction for multiple testing, were observed in 69% of features in the pancreatic volume and 51% in the tumor volume with B20f and I26f kernels. SVM models demonstrated accuracy ranging from 0.67 (95%CI: 0.50–0.81) to 0.83 (95%CI: 0.69–0.94) in distinguishing grade 1 cases from higher grades. Reconstruction kernels alter radiomics features and iterative kernel models trended towards higher performance. ComBat harmonization mitigates kernel impacts but addressing this effect is crucial in studies involving data from different kernels.