We designed small‐scale virus filtration models to investigate the impact of the extended process times and dynamic product streams present in continuous manufacturing. Our data show that the Planova 20N and BioEX virus filters are capable of effectively removing bacteriophage PP7 (>4 log) when run continuously for up to 4 days. Additionally, both Planova 20N and BioEX filters were able to successfully process a mock elution peak of increased protein, salt, and bacteriophage concentrations with only an increase in filtration pressure observed during the higher protein concentration peak. These experiments demonstrated that small‐scale viral clearance studies can be designed to model a continuous virus filtration step with specific process parameters.
Virus filtration (VF) is an important unit operation in the manufacture of biotherapeutics that provides robust removal of potential virus contaminants. Small virus removal can be impacted by the low operating pressures and potential depressurization events that are often associated with continuous operations where increased operational flexibility for higher loading at low flux and low pressure is required. In this study, we evaluated the impact of low flux (7 LMH) and pressure interruptions on minute virus of mice (MVM) removal. We used long‐term filtrations conducted to a target throughput of 1000 L/m2 with four different monoclonal antibodies on small‐scale hollow fiber virus filters with a hydrophilic modified polyvinylidene fluoride membrane. These conditions are certainly challenging for any VF operation and ensuring robust viral clearance under such conditions is critical to the design and implementation of continuous VF. Planova BioEX filters effectively removed MVM at 4 log or greater when run continuously for up to 6 days. Interestingly, pressure increases associated with filter fouling over the duration of long‐term filtrations were shown to be reflective of load material variability and could be remediated by implementation of an inline prefilter. Pressure interruptions had minimal impact on overall MVM logarithmic reduction value. Effective virus removal was achieved with pressure increases being largely product‐specific, which demonstrates the capability of the virus filter to remove virus independent of pressure increases that are expected to occur with increased protein load.