Shiqiang Zhuang

Dr. Shiqiang Zhuang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Carbon
Verified
Journal Article
Closed access
HSHarsimranjit Singh
Harsimranjit Singh
SZShiqiang Zhuang
Shiqiang Zhuang
BIBenjamin Ingis
Benjamin Ingis
Bharath Babu NunnaBharath Babu Nunna
Bharath Babu Nunna
ELEon Soo Lee
Eon Soo Lee

17 January 2019 in Nano Convergence
Verified
Journal Article
Open access
PDF file
Bharath Babu NunnaBharath Babu Nunna
Bharath Babu Nunna
DMDebdyuti Mandal
Debdyuti Mandal
JLJoo Un Lee
Joo Un Lee
HSHarsimranjit Singh
Harsimranjit Singh
SZShiqiang Zhuang
Shiqiang Zhuang
ELEon Soo Lee
Eon Soo Lee
Integrating microfluidics with biosensors is of great research interest with the increasing trend of lab-on-the chip and point-of-care devices. Though there have been numerous studies performed relating microfluidics to the biosensing mechanisms, the study of the sensitivity variation due to microfluidic flow is very much limited. In this paper, the sensitivity of interdigitated electrodes was evaluated at the static drop condition and the microfluidic flow condition. In addition, this study demonstrates the use of gold nanoparticles to enhance the sensor signal response and provides experimental results of the capacitance difference during cancer antigen-125 (CA-125) antigen–antibody conjugation at multiple concentrations of CA-125 antigens. The experimental results also provide evidence of disease-specific detection of CA-125 antigen at multiple concentrations with the increase in capacitive signal response proportional to the concentration of the CA-125 antigens. The capacitive signal response of antigen–antibody conjugation on interdigitate electrodes has been enhanced by approximately 2.8 times (from 260.80 to 736.33 pF at 20 kHz frequency) in static drop condition and approximately 2.5 times (from 205.85 to 518.48 pF at 20 kHz frequency) in microfluidic flow condition with gold nanoparticle-coating. The capacitive signal response is observed to decrease at microfluidic flow condition at both plain interdigitated electrodes (from 260.80 to 205.85 pF at 20 kHz frequency) and gold nano particle coated interdigitated electrodes (from 736.33 to 518.48 pF at 20 kHz frequency), due to the strong shear effect compared to static drop condition. However, the microfluidic channel in the biosensor has the potential to increase the signal to noise ratio due to plasma separation from the whole blood and lead to the increase concentration of the biomarkers in the blood volume for sensing.

1 July 2018 in Nano-Structures & Nano-Objects
Verified
Journal Article
Closed access
SZShiqiang Zhuang
Shiqiang Zhuang
Bharath Babu NunnaBharath Babu Nunna
Bharath Babu Nunna
DMDebdyuti Mandal
Debdyuti Mandal
ELEon Soo Lee
Eon Soo Lee


18 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DCDaniel Cao
Daniel Cao
BCBinqiang Chen
Binqiang Chen
BYBin Yao
Bin Yao
SZShiqiang Zhuang
Shiqiang Zhuang
Tool wear and breakage are inevitable due to the severe stress and high temperature in the cutting zone. A highly reliable tool condition monitoring system is necessary to increase productivity and quality, reduce tool costs and equipment downtime. Although many studies have been conducted, most of them focused on single-step process or continuous cutting. In this paper, a high robust milling tool wear monitoring methodology based on 2-D convolutional neural network (CNN) and derived wavelet frames (DWFs) is presented. The frequency band of high signal-to-noise ratio is extracted via derived wavelet frames, and the spectrum is further folded into a 2-D matrix to train 2-D CNN. The feature extraction ability of the 2-D CNN is fully utilized, bypassing the complex and low-portability feature engineering. The full life test of the end mill was carried out with S45C steel work piece and multiple sets of cutting conditions. The recognition accuracy of the proposed methodology reaches 98.5%, and the performance of 1-D CNN as well as the beneficial effects of the DWFs are verified.

3 December 2018 in Catalysts
Verified
Journal Article
Open access
PDF file
HSHarsimranjit Singh
Harsimranjit Singh
SZShiqiang Zhuang
Shiqiang Zhuang
Bharath Babu NunnaBharath Babu Nunna
Bharath Babu Nunna
ELEon Soo Lee
Eon Soo Lee
Here we report a nitrogen-doped graphene modified metal-organic framework (N-G/MOF) catalyst, a promising metal-free electrocatalyst exhibiting the potential to replace the noble metal catalyst from the electrochemical systems; such as fuel cells and metal-air batteries. The catalyst was synthesized with a planetary ball milling method, in which the precursors nitrogen-functionalized graphene (N-G) and ZIF-8 are ground at an optimized grinding speed and time. The N-G/MOF catalyst not only inherited large surface area from the ZIF-8 structure, but also had chemical interactions, resulting in an improved Oxygen Reduction Reaction (ORR) electrocatalyst. Thermogravimetric Analysis (TGA) curves revealed that the N-G/MOF catalyst still had some unreacted ZIF-8 particles, and the high catalytic activity of N-G particles decreased the decomposition temperature of ZIF-8 in the N-G/MOF catalyst. Also, we present the durability study of the N-G/MOF catalyst under a saturated nitrogen and oxygen environment in alkaline medium. Remarkably, the catalyst showed no change in the performance after 2000 cycles in the N2 environment, exhibiting strong resistance to the corrosion. In the O2 saturated electrolyte, the performance loss at lower overpotentials was as low compared to higher overpotentials. It is expected that the catalyst degradation mechanism during the potential cycling is due to the oxidative attack of the ORR intermediates.