The combination of flow elasticity and inertia has emerged as a viable tool for focusing and manipulating particles using microfluidics. Although there is considerable interest in the field of elasto-inertial microfluidics owing to its potential applications, research on particle focusing has been mostly limited to low Reynolds numbers (Re<1), and particle migration toward equilibrium positions has not been extensively examined. In this work, we thoroughly studied particle focusing on the dynamic range of flow rates and particle migration using straight microchannels with a single inlet high aspect ratio. We initially explored several parameters that had an impact on particle focusing, such as the particle size, channel dimensions, concentration of viscoelastic fluid, and flow rate. Our experimental work covered a wide range of dimensionless numbers (0.05 < Reynolds number < 85, 1.5 < Weissenberg number < 3800, 5 < Elasticity number < 470) using 3, 5, 7, and 10 µm particles. Our results showed that the particle size played a dominant role, and by tuning the parameters, particle focusing could be achieved at Reynolds numbers ranging from 0.2 (1 µL/min) to 85 (250 µL/min). Furthermore, we numerically and experimentally studied particle migration and reported differential particle migration for high-resolution separations of 5 µm, 7 µm and 10 µm particles in a sheathless flow at a throughput of 150 µL/min. Our work elucidates the complex particle transport in elasto-inertial flows and has great potential for the development of high-throughput and high-resolution particle separation for biomedical and environmental applications.
Detection and monitoring of lactate and glucose levels in biological fluids and cell cultures are essential for understanding metabolic disorders. While electrochemical biosensors are commonly used, traditional enzymatic sensors face challenges related to stability, reproducibility, and cost. To address these limitations, we developed non-enzymatic sensors for lactate and glucose detection using nanostructured nickel oxide (NiO)-modified screen-printed carbon electrodes. The sensors were fabricated by drop-casting a NiO/Nafion/ethanol dispersion onto the working electrode, and their performance was evaluated using cyclic voltammetry and amperometry. Optimal sensitivity and linearity were achieved at a working potential of ∼0.5 V. The sensors exhibited linear responses for both lactate and glucose in the 0.1-5 mM range, with detection limits of 0.03 mM (lactate) and 0.025 mM (glucose), and sensitivities of 1.564 μA/mM (lactate) and 1.842 μA/mM (glucose) in 0.1 M NaOH-KCl electrolyte. To address glucose interference in lactate sensing, dual-sensing strategies were employed by varying Nafion concentration, applying differential potentials, or modifying the sensors with Prussian Blue to achieve selective detection. Validation against commercial lactate and glucose assay kits in cell culture medium showed good agreement, confirming the sensors' accuracy. Finally, the sensor was integrated with a microfluidic chip, demonstrating its potential as a flow-through, enzyme-free metabolic sensor for future organ-on-a-chip applications.
Nanoscale biological particles, such as lipoproteins (10–80 nm) or extracellular vesicles (30–200 nm), play pivotal roles in health and disease, including conditions like cardiovascular disorders and cancer. Their effective analysis is crucial for applications in diagnostics, quality control, and nanomedicine development. While elasto‐inertial focusing offers a powerful method to manipulate particles without external fields, achieving consistent focusing of nanoparticles (<500 nm) has remained a challenge. In this study, elasto‐inertial focusing of nanoparticles as small as 25 nm is experimentally demonstrated using straight high‐aspect‐ratio microchannels in a sheathless flow. Systematic investigations reveal the influence of channel width, particle size, viscoelastic concentration, and flow rate on focusing behavior. Additionally, through numerical simulations and experimental validation, insights are provided into particle migration dynamics and viscoelastic forces governing nanoparticle focusing. Finally, biological particles, including liposomes (90–140 nm), extracellular vesicles (100 nm), and lipoproteins (10–25 nm) is successfully focused, under optimized conditions, showcasing potential applications in medical diagnostics and targeted drug delivery. These findings mark a significant advancement toward size‐based high‐resolution particle separation, with implications for biomedicine and environmental sciences.
Micro- and nanoplastics have become increasingly relevant as contaminants to be monitored due to their potential health effects and environmental impact. Nanoplastics, in particular, have been shown to be difficult to detect in drinking water, requiring new capture technologies. In this work, we applied the acoustofluidic seed particle method to capture nanoplastics in an optimized, tilted grid of silica clusters even at the high flow rate of 5 mL/min. Moreover, we achieved, using this technique, the enrichment of nanoparticles ranging from 500 nm to 25 nm as a first in the field. We employed fluorescence to observe the enrichment profiles according to size, using a washing buffer flow at 0.5 mL/min, highlighting the size-dependent nature of the silica seed particle release of various sizes of nanoparticles. These results highlight the versatility of acoustic trapping for a wide range of nanoplastic particles and allow further study into the complex dynamics of the seed particle method at these size ranges. Moreover, with reproducible size-dependent washing curves, we provide a new window into the rate of nanoplastic escape in high-capacity acoustic traps, relevant to both environmental and biomedical applications.
Nanoscale biological particles, such as lipoproteins (10–80 nm) or extracellular vesicles (30–200 nm), play pivotal roles in health and disease, including conditions like cardiovascular disorders and cancer. Their effective analysis is crucial for applications in diagnostics, quality control, and nanomedicine development. While elasto-inertial focusing offers a powerful method to manipulate particles without external fields, achieving consistent focusing of nanoparticles (<500 nm) has remained a challenge. In this study, we experimentally demonstrate elasto-inertial focusing of nanoparticles as small as 25 nm using straight high-aspect-ratio microchannels in a sheathless flow. Systematic investigations reveal the influence of channel width, particle size, viscoelastic concentration, and flow rate on focusing behavior. Additionally, through numerical simulations and experimental validation, we provide insights into particle migration dynamics and viscoelastic forces governing nanoparticle focusing. Finally, we successfully focus biological particles, including liposomes (90–140 nm), extracellular vesicles (100 nm), and lipoproteins (10–25 nm), under optimized conditions, showcasing potential applications in medical diagnostics and targeted drug delivery. These findings mark a significant advancement toward size-based high-resolution particle separation, with implications for biomedicine and environmental sciences.
Micro and nanoplastics have become increasingly relevant as contaminants to be monitored due to their potential health effects and environmental impact. Nanoplastics, in particular, have been shown to be difficult to detect in drinking water, requiring new capture technologies. In this work, we applied the acoustofluidic seed particle method to capture nanoplastics in an optimized, tilted grid of silica clusters even at the high flow rate of 5 mL/min. Moreover, we achieved, using this technique, the enrichment of nanoparticles ranging from 500 nm to 25 nm as a first in the field. We employ fluorescence to observe the enrichment profiles according to size, using washing buffer flow at 0.5 mL/min, highlighting the size-dependent nature of silica seed particle release of various sizes of nanoparticle. These results highlight the versatility of acoustic trapping for a wide range of nanoplastic particles and allow further study into the complex dynamics of the seed particle method at these size ranges. Moreover, with reproducible size-dependent washing curves, we provide a new window into the rate of nanoplastic escape in high-capacity acoustic traps, relevant for both environmental and biomedical applications.