Ganesh-Babu Balu Subburaman

Dr. Ganesh-Babu Balu Subburaman

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Management Science
Verified
Journal Article
Closed access
KDKraig Delana
Kraig Delana
SDSarang Deo
Sarang Deo
KRKamalini Ramdas
Kamalini Ramdas
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman
Thulasiraj RavillaThulasiraj Ravilla
Thulasiraj Ravilla
Telemedicine is increasingly used across the developing world to expand access to healthcare, to improve outcomes, and to reduce costs. One common model is that of telemedicine centers, which are small primary care facilities run by midlevel (nonphysician) providers who conduct a preliminary examination and then facilitate a telemedicine visit with a remote physician in real time. However, the impact of this channel of care delivery—particularly on existing physical healthcare-delivery channels—has not been thoroughly examined. We use data from one of the largest tele-ophthalmology implementations in the world to examine this issue. Using a quasi-experimental difference-in-differences approach, we find that opening a nearby telemedicine center generates a 31% increase in the overall network visit rate from the population within 10 km of the new center, 62% of which is driven by new patients, suggesting a substantial increase in access. The rate of eyeglasses prescriptions to correct for simple refractive errors increases by 18.5%, whereas the rate of cataract surgery to replace the natural lens in a patient’s eye with an artificial lens remains unchanged. The increase in access and treatment rates does not significantly impact the direct costs incurred by patients, but reduces their indirect costs (measured as travel distance) by 30% (12 km). Finally, we find significant spatial heterogeneity in these effects, which vary with the distance of patients to facilities. These results have important implications for the design of telemedicine networks and the portfolio of healthcare services provided through them. This paper was accepted by Stefan Scholtes, healthcare management. Supplemental Material: The data files and online appendix are available at https://doi.org/10.1287/mnsc.2022.4488 .

1 November 2019 in Ophthalmology
Verified
Journal Article
Closed access
JCJacob T. Cox
Jacob T. Cox
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman
BMBeatriz Munoz
Beatriz Munoz
DFDavid S. Friedman
David S. Friedman
RRRavilla D. Ravindran
Ravilla D. Ravindran

1 August 2023 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
CVChandrakumar Subbiah Vasan
Chandrakumar Subbiah Vasan
SGSachin Gupta
Sachin Gupta
MSMadhu Shekhar
Madhu Shekhar
KNKamatchi Nagu
Kamatchi Nagu
LBLogesh Balakrishnan
Logesh Balakrishnan
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman
Purpose: To assess the accuracy of e-Paarvai, an artificial intelligence-based smartphone application (app) that detects and grades cataracts using images taken with a smartphone by comparing with slit lamp-based diagnoses by trained ophthalmologists. Methods: In this prospective diagnostic study conducted between January and April 2022 at a large tertiary-care eye hospital in South India, two screeners were trained to use the app. Patients aged >40 years and with a best-corrected visual acuity <20/40 were recruited for the study. The app is intended to determine whether the eye has immature cataract, mature cataract, posterior chamber intra-ocular lens, or no cataract. The diagnosis of the app was compared with that of trained ophthalmologists based on slit-lamp examinations, the gold standard, and a receiver operating characteristic (ROC) curve was estimated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were computed. Results: The two screeners used the app to screen 2,619 eyes of 1,407 patients. In detecting cataracts, the app showed high sensitivity (96%) but low specificity (25%), an overall accuracy of 88%, a PPV of 92.3%, and an NPV of 57.8%. In terms of cataract grading, the accuracy of the app was high in detecting immature cataracts (1,875 eyes, 94.2%), but its accuracy was poor in detecting mature cataracts (73 eyes, 22%), posterior chamber intra-ocular lenses (55 eyes, 29.3%), and clear lenses (2 eyes, 2%). We found that the area under the curve in predicting ophthalmologists’ cataract diagnosis could potentially be improved beyond the app’s diagnosis based on using images only by incorporating information about patient sex and age (P < 0.0001) and best-corrected visual acuity (P < 0.0001). Conclusions: Although there is room for improvement, e-Paarvai app is a promising approach for diagnosing cataracts in difficult-to-reach populations. Integrating this with existing outreach programs can enhance the case detection rate.

10 September 2020 in Eye
Verified
Journal Article
Closed access
PDF file
RRRavilla D. Ravindran
Ravilla D. Ravindran
SGSachin Gupta
Sachin Gupta
AHAravind Haripriya
Aravind Haripriya
Thulasiraj RavillaThulasiraj Ravilla
Thulasiraj Ravilla
ASAshok Vardhan S
Ashok Vardhan S
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman

8 August 2023 in Eye
Verified
Journal Article
Closed access
PDF file
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman
AGAnitha Gunasekaran
Anitha Gunasekaran
SCSivakumar Chandrashekaran
Sivakumar Chandrashekaran
RRRavilla D. Ravindran
Ravilla D. Ravindran
FMFrits van Merode
Frits van Merode
SGSachin Gupta
Sachin Gupta

1 June 2019 in Ophthalmology
Verified
Journal Article
Closed access
SGSachin Gupta
Sachin Gupta
RRRavilla D. Ravindran
Ravilla D. Ravindran
GSGanesh-Babu Balu Subburaman
Ganesh-Babu Balu Subburaman
ASAshok Vardhan S.
Ashok Vardhan S.
Thulasiraj RavillaThulasiraj Ravilla
Thulasiraj Ravilla