The recent technological and computational advances in mass spectrometry-based single-cell proteomics have pushed the boundaries of sensitivity and throughput. However, reproducible quantification of thousands of proteins within a single cell remains challenging. To address some of those limitations, we present a dedicated sample preparation chip, the proteoCHIP EVO 96 that directly interfaces with the Evosep One. This, in combination with the Bruker timsTOF demonstrates double the identifications without manual sample handling and the newest generation timsTOF Ultra identifies up to 4000 with an average of 3500 protein groups per single HEK-293T without a carrier or match-between runs. Our workflow spans 4 orders of magnitude, identifies over 50 E3 ubiquitin-protein ligases, and profiles key regulatory proteins upon small molecule stimulation. This study demonstrates that the proteoCHIP EVO 96-based sample preparation with the timsTOF Ultra provides sufficient proteome depth to study complex biology beyond cell-type classifications.
14 October 2023 in Molecular & Cellular Proteomics
Multiplexed and label-free mass spectrometry-based approaches with single-cell resolution have attributed surprising heterogeneity to presumed homogenous cell populations. Even though specialized experimental designs and instrumentation have demonstrated remarkable advances, the efficient sample preparation of single cells still lags. Here, we introduce the proteoCHIP, a universal option for single-cell proteomics sample preparation including multiplexed labeling up to 16-plex with high sensitivity and throughput. The automated processing using a commercial system combining single-cell isolation and picoliter dispensing, the cellenONE, reduces final sample volumes to low nanoliters submerged in a hexadecane layer simultaneously eliminating error-prone manual sample handling and overcoming evaporation. The specialized proteoCHIP design allows direct injection of single cells via a standard autosampler resulting in around 1500 protein groups per TMT10-plex with reduced or eliminated need for a carrier proteome. We evaluated the effect of wider precursor isolation windows at single-cell input levels and found that using 2 Da isolation windows increased overall sensitivity without significantly impacting interference. Using the dedicated mass spectrometry acquisition strategies detailed here, we identified on average close to 2000 proteins per TMT10-plex across 170 multiplexed single cells that readily distinguished human cell types. Overall, our workflow combines highly efficient sample preparation, chromatographic and ion mobility-based filtering, rapid wide-window data-dependent acquisition analysis, and intelligent data analysis for optimal multiplexed single-cell proteomics. This versatile and automated proteoCHIP-based sample preparation approach is sufficiently sensitive to drive biological applications of single-cell proteomics and can be readily adopted by proteomics laboratories.
Mass spectrometry‐based proteomics comprehensively defines proteome expression patterns in thousands of cells majorly contributing to our current understanding of many biological processes. More recently, single‐cell transcriptome and genome studies, however, have demonstrated overwhelming heterogeneity of tissues and cellular subpopulations. These studies have indicated different cellular functionality and identity, which are mainly driven by proteins and their posttranscriptional modifications. The rapidly emerging field of single‐cell proteomics aims at complementing transcriptome and genome data by generating comparative protein expression profiles from individual cells. Recent developments demonstrated tremendous improvements in sample preparation workflows and MS instrumentation, quantifying over 1000 proteins from a single cell. Efficient and reproducible sample processing in conjunction with sensitive MS acquisition strategies will allow to further increase the proteome coverage of tissues with single‐cell resolution. The required throughput and data reliability of such studies are still subject to further developments. Therefore, we herein discuss recent progress on specialized workflows and instrumentation next to advancements outside the field, which we expect to contribute to the development of comprehensive single‐cell proteomics.
Capitalizing on the massive increase in sample concentrations which are produced by extremely low elution volumes, nano-LC-ESI-MS/MS is currently one of the most sensitive analytical technologies for the comprehensive characterization of complex protein samples. However, despite tremendous technological improvements made in the production and the packing of monodisperse spherical particles for nano-flow HPLC, current state-of-the-art systems still suffer from limits in operation at the maximum potential of the technology. With the recent introduction of the µPAC system, which provides perfectly ordered micro-pillar array based chromatographic support materials, completely new chromatographic concepts for optimization towards the needs of ultra-sensitive proteomics become available. Here we report on a series of benchmarking experiments comparing the performance of a commercially available 50 cm micro-pillar array column to a widely used nano-flow HPLC column for the proteomics analysis of 10 ng tryptic HeLa cell digest. Comparative analysis of LC-MS/MS-data corroborated that micro-pillar array cartridges provide outstanding chromatographic performance, excellent retention time stability, increase sensitivity in the analysis of low-input proteomics samples, and thus repeatedly yielded almost twice as many unique peptide and unique protein group identifications when compared to conventional nano-flow HPLC columns.
The analysis of single-cell proteomes has recently become a viable complement to transcriptomics and genomics studies. Proteins are the primary driver of cellular functionality and mRNA levels are often an unreliable proxy of such. Therefore, the global analysis of the proteome is essential to study cellular identities. Multiplexed and label-free mass spectrometry-based approaches with single-cell resolution have lately attributed surprising heterogeneity to presumed homogenous cell populations. Even though specialized experimental designs and instrumentation have demonstrated remarkable advances, the efficient sample preparation of single cells still lag. Here, we introduce the proteoCHIP, a universal option for single-cell proteomics sample preparation at surprising sensitivity and throughput. The automated processing using a commercial system combining single-cell isolation and picoliter dispensing, the cellenONE ® , reduces final sample volumes to low nanoliters submerged in a hexadecane layer simultaneously eliminating error-prone manual sample handling and overcoming evaporation. The specialized proteoCHIP design allows direct injection of single cells via a standard autosampler resulting in around 1,500 protein groups per analytical run at remarkable reporter ion signal to noise while reducing or eliminating the carrier proteome. We identified close to 2,600 proteins across 170 multiplexed single cells from two highly similar human cell types. This dedicated loss-less workflow allows distinguishing in vitro co-differentiated cell types of self-organizing cardiac organoids based on indicative markers across 150 single cells. In-depth characterization revealed enhanced cellular motility of cardiac endothelial cells and sarcomere organization in cardiomyocytes. Our versatile and automated sample preparation has not only proven to be easily adaptable but is also sufficiently sensitive to drive biological applications of single-cell proteomics.
Comprehensive and in-depth identification of the human leukocyte antigen class I (HLA-I) and class II (HLA-II) tumor immunopeptidome can inform the development of cancer immunotherapies. Mass spectrometry (MS) is a powerful technology for direct identification of HLA peptides from patient-derived tumor samples or cell lines. However, achieving sufficient coverage to detect rare and clinically relevant antigens requires highly sensitive MS-based acquisition methods and large amounts of sample. While immunopeptidome depth can be increased by off-line fractionation prior to MS, its use is impractical when analyzing limited amounts of primary tissue biopsies. To address this challenge, we developed and applied a high-throughput, sensitive, and single-shot MS-based immunopeptidomics workflow that leverages trapped ion mobility time-of-flight MS on the Bruker timsTOF single-cell proteomics system (SCP). We demonstrate greater than twofold improved coverage of HLA immunopeptidomes relative to prior methods with up to 15,000 distinct HLA-I and HLA-II peptides from 4e7 cells. Our optimized single-shot MS acquisition method on the timsTOF SCP maintains high coverage, eliminates the need for off-line fractionation, and reduces input requirements to as few as 1e6 A375 cells for >800 distinct HLA-I peptides. This depth is sufficient to identify HLA-I peptides derived from cancer-testis antigen and noncanonical proteins. We also apply our optimized single-shot SCP acquisition methods to tumor-derived samples, enabling sensitive, high-throughput, and reproducible immunopeptidome profiling with detection of clinically relevant peptides from less than 4e7 cells or 15 mg wet weight tissue.