Anton Volniansky

Dr. Anton Volniansky


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
RRRaheem Remtulla
Raheem Remtulla
ASAdam Samet
Adam Samet
Merve KulbayMerve Kulbay
Merve Kulbay
AAArjin Akdag
Arjin Akdag
AHAdam Hocini
Adam Hocini
CQCynthia X Qian
Cynthia X Qian
Machine learning has transformed ophthalmology, particularly in predictive and discriminatory models for vitreoretinal pathologies. However, generative modeling, especially generative adversarial networks (GANs), remains underexplored. GANs consist of two neural networks—the generator and discriminator—that work in opposition to synthesize highly realistic images. These synthetic images can enhance diagnostic accuracy, expand the capabilities of imaging technologies, and predict treatment responses. GANs have already been applied to fundus imaging, optical coherence tomography (OCT), and fluorescein autofluorescence (FA). Despite their potential, GANs face challenges in reliability and accuracy. This review explores GAN architecture, their advantages over other deep learning models, and their clinical applications in retinal disease diagnosis and treatment monitoring. Furthermore, we discuss the limitations of current GAN models and propose novel applications combining GANs with OCT, OCT-angiography, fluorescein angiography, fundus imaging, electroretinograms, visual fields, and indocyanine green angiography.

24 October 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
ANAmirhosein Baradaran Najar
Amirhosein Baradaran Najar
GGGuillaume Gilbert
Guillaume Gilbert
EKElige Karam
Elige Karam
AVAnton Volniansky
Anton Volniansky
AFAudrey Fohlen
Audrey Fohlen
EHElijah Van Houten
Elijah Van Houten
Background: Intrinsic activation MR elastography (iMRE) uses cardiovascular pulsations to assess tissue viscoelastic properties. Applying it to focal liver lesions extends its capabilities.Purpose: To assess the viscoelastic parameters of focal liver lesions measured by iMRE and compare its diagnostic performance with extrinsic MRE (eMRE) for differentiating malignant and benign lesions.Study type: Prospective.Population: A total of 55 participants underwent MRI with research MRE sequences; 32 participants with 17 malignant and 15 benign lesions underwent both iMRE and eMRE.Field Strength/Sequence: iMRE at ~1 Hz heart rate used a 3 T scanner with a modified four‐dimensional (4D)‐quantitative flow gradient‐echo phase contrast and low‐velocity encoding cardiac‐triggered technique. eMRE employed a gradient‐echo sequence at 30, 40, and 60 Hz.Assessment: Liver displacements were measured using 4D‐phase contrast and reconstructed via a nonlinear inversion algorithm to determine shear stiffness (SS) and damping ratio (DR). iMRE parameters were normalized to the corresponding values from the spleen. Lesions were manually segmented, and image quality was reviewed.Statistical Tests: Kruskal–Wallis, Mann–Whitney, Dunn's test, and areas under receiver operating characteristic curves (AUC) were assessed.Results: SS was significantly higher in malignant than benign lesions with iMRE at 1 Hz (3.69 ± 1.31 vs. 1.63 ± 0.45) and eMRE at 30 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), 40 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), and 60 Hz (7.32 ± 2.87 vs. 2.48 ± 1.12 kPa). DR was also significantly higher in malignant than benign lesions at 40 Hz (0.36 ± 0.11 vs. 0.21 ± 0.01) and 60 Hz (0.89 ± 0.86 vs. 0.22 ± 0.09). The AUC were 0.86 for iMRE SS, 0.87–0.98 for eMRE SS, 0.47 for iMRE DR, and 0.62–0.86 for eMRE DR.Data Conclusion: Cardiac‐activated iMRE can characterize liver lesions and differentiate malignant from benign lesions through normalized SS maps.Level of Evidence: 2Technical Efficacy: Stage 2

28 November 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
AVAnton Volniansky
Anton Volniansky
TLThierry L. Lefebvre
Thierry L. Lefebvre
MKMerve Kulbay
Merve Kulbay
GGGuillaume Gilbert
Guillaume Gilbert
BFBoyan Fan
Boyan Fan
ATAn Tang
An Tang
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.

17 November 2025 in Canadian Journal of Ophthalmology
Verified
Journal Article
Open access
STStuti Misty Tanya
Stuti Misty Tanya
RPRaj Pathak
Raj Pathak
RRRaheem Remtulla
Raheem Remtulla
AJArmaan Jaffer
Armaan Jaffer
Merve KulbayMerve Kulbay
Merve Kulbay
FKFemida Kherani
Femida Kherani
We describe the evolution of the demographics in the Canadian ophthalmology workforce and compare these trends to other surgical specialists. A longitudinal observational study. Surgical specialists identified in the Canadian Institute for Health Information's "Supply, Distribution, and Migration of Physicians in Canada" (SDMP) database from 1971 to 2022. Categories included cardiac, general, orthopedic, plastic, and vascular surgery; obstetrics and gynecology; ophthalmology; otolaryngology; and urology. Demographic data were extracted from the SDMP database. Descriptive statistics were used to determine mean age, male-to-female ratio, urban-to-rural ratio, percentage of physicians under age 40 and above age 65, Canadian-to-foreign trained ratio, and physicians-to-100,000 population ratio for ophthalmologists and other surgeons by decade. Ophthalmologists and other surgeons aged significantly, and ophthalmologists were significantly older than other surgeons (mean age: 52.15 vs 49.73 years; p < 0.01). The percentage above age 65 doubled for both groups, reaching 21.51% for ophthalmologists and 15.31% for other surgeons. Male-to-female ratios decreased 11-fold for ophthalmologists, now 2.54:1, and 17-fold for other surgeons, now 2.01:1. Surgeon-to-100,000 population ratio increased from 22.97 to 25.53 (p < 0.001), whereas ophthalmologist ratios increased slightly from 3.27 to 3.51 (p < 0.001). Urban-to-rural distribution increased by 34.67% for surgeons but decreased by 32.27% for ophthalmologists. Both groups saw an increase in Canadian-trained practitioners, with ratios rising to 5.23:1 for surgeons and 5.41:1 for ophthalmologists by the 2020s. The percentage of ophthalmologists and other surgeons above age 65 years has doubled. Ophthalmologists remain significantly older than other surgeons. The ophthalmologists-to-100,000 population ratio, presently 3.51, meets the recommended goal of 3.37-to-100,000 population.

23 August 2024 in Magnetic Resonance Imaging
Verified
Journal Article
Open access
AVAnton Volniansky
Anton Volniansky
TLThierry L. Lefebvre
Thierry L. Lefebvre
Merve KulbayMerve Kulbay
Merve Kulbay
BFBoyan Fan
Boyan Fan
EAEmre Aslan
Emre Aslan
ATAn Tang
An Tang
Background: Despite the widespread use of diffusion-weighted imaging (DWI) in metabolic dysfunction- associated fatty liver disease (MAFLD), MRI acquisition and quantification techniques vary in the literature suggesting the need for established and reproducible protocols. The goal of this study was to assess inter-visit and inter-reader reproducibility of DWI- and IVIM-derived parameters in patients with MAFLD and healthy volunteers using extensive sampling of the "fast" compartment, non-rigid registration, and exclusion voxels with poor fit quality. Methods: From June 2019 to April 2023, 31 subjects (20 patients with biopsy-proven MAFLD and 11 healthy volunteers) were included in this IRB-approved study. Subjects underwent MRI examinations twice within 40 days. 3.0 T DWI was acquired using a respiratory-triggered spin-echo diffusion-weighted echo-planar imaging sequence (b b-values of 0, 10, 20, 30, 40, 50, 100, 200, 400, 800 s/mm2). 2 ). DWI series were co-registered prior to voxel-wise non-linear regression of the IVIM model and voxels with poor fit quality were excluded (normalized root mean squared error >= 0.05). IVIM parameters (perfusion fraction, f ; diffusion coefficient, D ; and pseudo- diffusion coefficient, D* ), and apparent diffusion coefficients (ADC) were computed from manual segmentation of the right liver lobe performed by two analysts on two MRI examinations. Results: All results are reported for f , D , D* , and ADC respectively. For inter-reader agreement on the first visit, ICC were of 0.985, 0.994, 0.986, and 0.993 respectively. For intra-reader agreement of analyst 1 assessed on both imaging examinations, ICC between visits were of 0.805, 0.759, 0.511, and 0.850 respectively. For inter-reader agreement on the first visit, mean bias and 95 % limits of agreement were (0.00 f 0.03), (-0.01 f 0.03) x 10-3-3 mm2/s, 2 /s, (0.70 f 10.40) x 10-3-3 mm2/s, 2 /s, and (-0.02 f 0.04) x 10-3-3 mm2/s 2 /s respectively. For intra-reader agreement of analyst 1, mean bias and 95 % limits of agreement were (0.01 f 0.09) x 10-3-3 mm2/s, 2 /s, (-0.01 f 0.21) x 10-3-3 mm2/s, 2 /s, (-13.37 f 56.19) x 10-3-3 mm2/s, 2 /s, and (-0.01 f 0.16) x 10-3-3 mm2/s 2 /s respectively. Except for parameter D* that was associated with between-subjects parameter variability (P P 1 / 4 0.009), there was no significant variability between subjects, examinations, or readers. Conclusion: With our approach, IVIM parameters f , D , D* , and ADC provided excellent inter-reader agreement and good to very good inter-visit or intra-reader agreement, thus showing the reproducibility of IVIM-DWI of the liver in MAFLD patients and volunteers.

10 November 2025 in Radiology Advances
Verified
Journal Article
Open access
ANAmirhosein Baradaran Najar
Amirhosein Baradaran Najar
GGGuillaume Gilbert
Guillaume Gilbert
AVAnton Volniansky
Anton Volniansky
EKElige Karam
Elige Karam
AFAudrey Fohlen
Audrey Fohlen
ATAn Tang
An Tang
Background: Noninvasive grading of liver inflammation in metabolic dysfunction-associated steatotic liver disease (MASLD) remains an unmet clinical need. Purpose: To evaluate the diagnostic performance of multifrequency MR elastography (MMRE) for grading liver inflammation and diagnosing metabolic dysfunction-associated steatohepatitis (MASH). Materials and methods: In this prospective, single-site study, participants underwent MMRE at 30, 40, and 60 Hz on a 3T system. Multifrequency dispersion coefficient (α), storage modulus (G'), loss modulus (G”), and magnitude of the shear modulus (|G*|) were computed. The reference standard was histopathological analysis of needle biopsy specimens. The MASLD activity score was computed to assign MASH status. Univariate and multivariable correlation and areas under the receiver operating characteristic curve (AUCs) were assessed. Results: Of the 72 participants enrolled, 60 (12 healthy, 48 MASLD) were analyzable. Correlations of α, G', G”, and |G*| with lobular inflammation grades were ρ = −0.62, P < .001; ρ = 0.46, P < .001; ρ = 0.39, P < .01; and ρ = 0.44, P < .001; and the corresponding correlations with ballooning ρ = −0.42, P < .001; ρ = 0.42, P < .001; ρ = 0.40, P < .001; and ρ = 0.41, P < .001. The correlation between α and lobular inflammation remained after adjusting for steatosis, ballooning, and fibrosis (β = −0.06, P < .001); and with ballooning after adjusting for steatosis, lobular inflammation, and fibrosis (β = −0.02, P < .01). AUCs of α were 0.85, 0.96, and 0.94, respectively, for distinguishing lobular inflammation grades 0 vs ≥1, ≤1 vs ≥2, and ≤2 vs 3; 0.84 and 0.78 for distinguishing ballooning grades 0 vs ≥1 and ≤1 vs 2; and 0.81 to 0.85 for diagnosing MASH. Conclusion: The multifrequency dispersion coefficient α was associated with histologic inflammation and should be further evaluated with external validation as a possible clinical marker in MASLD.