This study describes a maiden application of salp swarm algorithm (SSA) optimised cascade tilt–integral–derivative controller (CC‐TID) for frequency and tie‐line power control of interconnected power systems (IPSs). The proposed controller includes both the merit of the cascade control algorithm and fractional‐order calculus. In the proposed CC‐TID controller, TID controller is used as a slave controller and a proportional–integral (PI) controller served the role of master controller. To elucidate the effectiveness, the designed controller has employed to, initially, two‐area IPS followed by four‐area IPS. SSA is used to pursue the optimum settings of the CC‐TID controller via the minimisation of area control error. Performances of CC‐TID controller is obtained and compared with I‐, PI‐, PI–derivative‐, cascade PI–PD, and TID controllers. Simulation results, apparently, show that SSA: CC‐TID controller exhibits superior performance compared with other controllers described above. Moreover, the performance of SSA is evaluated and compared with differential evolution and flower pollination algorithm in terms of convergence profile, power density, and statistical results. Finally, time‐varying step load perturbation and random load perturbation are applied to confirm the robust behaviour of SSA: CC‐TID controller.
An effort has been given to derive the reduced-order models (ROMs) of higher-order power systems using model-order reduction techniques. Fractional-order proportional-integral-derivative (FOPI-D) controller is designed and incorporated in the models to cope up the load perturbation and to provide adequate damping to the system oscillation. To avoid the set-point kick problem of PID controller, the derivative action is considered in the feedback path that results in PI-D controller. Grasshopper optimization algorithm (GOA) has been used to optimize the FOPI-D controller gains. To affirm tuning competence of GOA, the convergence mobility of the GOA is compared with some well-known optimization techniques. The analysis of the system responses carried out in this work demonstrates that the controller design effort is significantly reduced with the derived ROMs, and confirms the matching of time and frequency responses with the higher-order system. To quantify the efficacy of FOPI-D controller, the closed-loop responses are compared with some conventional and intelligent controllers. From the presented result, substantial improvements in the system dynamics are observed with GOA: FOPI-D controller in normal circumstances as well as in the presence of system uncertainties. The success of GOA: FOPI-D controller is also confirmed for a hybrid energy distributed power system.
7 August 2017 in IET Generation, Transmission & Distribution
In this article, a maiden attempt has been made to derive an optimal and effective outcome of load frequency control problem (LFC) using a novel evolutionary algorithm called multi‐verse optimisation. The main inspiration of this algorithm is based on three concepts in cosmology: white hole, black hole, and wormhole. To show the effectiveness, a four‐area hydrothermal power plant with distinct proportional‐integral‐derivative (PID) controller is investigated at the first instant and then the study is forwarded to the five‐area thermal power plant. To enhance the dynamic stability, an optimal PID plus double‐derivative controller (PID + DD) is designed and included in the control areas. The superiority of the proposed method has been established over some recently addressed control algorithms by transient analysis method. To add some degree of non‐linearity, generation rate constraint and governor dead band are included in the model and their impacts on the system dynamics have been examined. Finally, a random load perturbation is given to the test systems to affirm the robustness of the designed controllers.
9 December 2020 in IET Generation, Transmission & Distribution
This work demonstrates a maiden application of a fractional‐order based three‐degree‐of‐freedom tilt‐integral‐derivative controller for escalating the load frequency control performance of power system having wind power generator integrated. The disturbance observer is housed with the proposed fractional‐order‐three‐degree‐of‐freedom‐tilt‐integral‐derivative controller to efficiently estimate the wind velocity's uncertain profile and subsequently enrich the control law. The mastery of the proposed control algorithm has been tested on multi‐area interconnected power systems by performing an extensive comparative study with other prevalent techniques reported in the state‐of‐art. Harris' Hawks optimisation is applied to explore the proposed controllers' optimum gains, exercising an integral error‐based criterion. Time response measurements of the studied test systems in the wake of load fluctuation and intermittent output of wind power generator explicitly establish the efficacy of the proposed Harris' Hawks optimisation tuned disturbance observer‐based fractional‐order‐three‐degree‐of‐freedom‐tilt‐integral‐derivative controller over its other counterparts concerning damping of system oscillations. Furthermore, the developed control system's robust stability is affirmed using Kharitonov's stability theorem, considering ±25% variation in system parameters.
11 November 2020 in International Transactions on Electrical Energy Systems