Jin Woong Lee

Dr. Jin Woong Lee

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JLJin Woong Lee
Jin Woong Lee
SCSeok-Ryul Choi
Seok-Ryul Choi
JLJung Heon Lee
Jung Heon Lee

1 January 2017 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
JLJung Heon Lee
Jung Heon Lee
GYGyu Sung Yi
Gyu Sung Yi
JLJin Woong Lee
Jin Woong Lee
DKDeug Joong Kim
Deug Joong Kim
Lee JH, et al. J Periodontal Implant Sci. 2017 Dec;47(6):388-401. https://doi.org/10.5051/jpis.2017.47.6.388

5 May 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
SJSun Hwan Jeong
Sun Hwan Jeong
JHJun Hyuk Heo
Jun Hyuk Heo
JLJin Woong Lee
Jin Woong Lee
MKMin Jeong Kim
Min Jeong Kim
CPCheol Hyun Park
Cheol Hyun Park
JLJung Heon Lee
Jung Heon Lee
The development of eco-friendly flame retardants is crucial due to the hazardous properties of most conventional flame retardants. Herein, adenosine triphosphate (ATP) is reported to be a highly efficient “all-in-one” green flame retardant as it consists of three essential groups, which lead to the formation of char with extreme intumescence, namely, three phosphate groups, providing an acid source; one ribose sugar, working as a char source; and one adenine, acting as a blowing agent. Polyurethane foam was used as a model flammable material to demonstrate the exceptional flame retardancy of ATP. The direct flammability tests have clearly shown that the ATP-coated polyurethane (PU) foam almost did not burn upon exposure to the torch flame. Importantly, ATP exhibits an extreme volume increase, whereas general phosphorus-based flame retardants show a negligible increase in volume. The PU foam coated with 30 wt % of ATP (PU-ATP 30 wt %) exhibits a significant reduction in the peak heat release rate (94.3%) with a significant increase in the ignition time, compared to bare PU. In addition, PU-ATP 30 wt % exhibits a high limiting oxygen index (LOI) value of 31% and HF-1 rating in the UL94 horizontal burning foamed material test. Additionally, we demonstrated that ATP’s flame retardancy is sufficient for other types of matrices such as cotton, as confirmed from the results of the standardized ASTM D6413 test; cotton-ATP 30 wt % exhibits an LOI value of 32% and passes the vertical flame test. These results strongly suggest that ATP has great potential to be used as an “all-in-one” green flame retardant.

26 November 2018 in Nano Letters
Verified
Journal Article
Closed access
JLJin Woong Lee
Jin Woong Lee
SCSudong Chae
Sudong Chae
SOSeoungbae Oh
Seoungbae Oh
SKSi Hyun Kim
Si Hyun Kim
KCKyung Hwan Choi
Kyung Hwan Choi
JCJae Young Choi
Jae Young Choi

6 October 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
JLJung Heon Lee
Jung Heon Lee
HCHui Hun Cho
Hui Hun Cho
JLJin Woong Lee
Jin Woong Lee
JLJung Heon Lee
Jung Heon Lee
We developed a method to convert a general colorimetric sensor to an achromatic colorimetric sensor by introducing a complementary colored dye to the sensor, helping users to detect the presence of analytes at much lower concentration and recognize the existence of analytes instinctively.

26 October 2022 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
JLJin Woong Lee
Jin Woong Lee
SCSudong Chae
Sudong Chae
SOSeungbae Oh
Seungbae Oh
DKDai‐Hwan Kim
Dai‐Hwan Kim
SKSi Hyun Kim
Si Hyun Kim
SSSi Young Song
Si Young Song