Ya Jie Knöbl

Ms. Ya Jie Knöbl

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2025 in ACS Sensors
Verified
Journal Article
Open access
YKYa Jie Knöbl
Ya Jie Knöbl
INIman Nakhli
Iman Nakhli
MDMaría del Mar Darder
María del Mar Darder
Guillermo OrellanaGuillermo Orellana
Guillermo Orellana
Current commercial turbidity sensors may be costly, bulky, or fragile. As such, many research groups have investigated alternative methods for the accurate determination of this essential water quality parameter. This work describes a new sensor based on luminescence measurements under a dual-lifetime reference scheme. By letting the turbid water pass between two dye layers with similar absorption and emission features but widely different emission lifetimes, an overall luminescence phase shift is measured, the magnitude of which depends on the turbidity. Dimethyl 2,5-bis(cyclohexylamino)terephthalate (BCT) is the reference fluorophore placed on the optical fiber tip after immobilization in a thin poly(vinyl chloride) (PVC) layer. The indicator luminophore, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) (RD3), embedded into poly(ethyl 2-cyanoacrylate) (PCA), is separated from the reference layer by a user-selectable distance (1-2 cm). With increasing turbidity, the emission intensity of the indicator dye layer decreases, while the fluorescence intensity of the reference layer remains constant. In this way, the ratio between the two emission intensities is translated into changes in the lifetime (and phase shift) of the composite emission. The sensor's working range depends on the distance between the two dye layers. The sensor is capable of detecting turbidity levels in the range of 0-1000 NTU, 0-500 NTU, and 0-300 NTU for 1, 1.5, and 2 cm optical pathlengths, respectively, with an accuracy of 1 NTU (0.3 NTU between 0 and 10 NTU), limited by the accuracy of the turbidity standards. Shorter pathlengths allow the measurement of higher turbidity. The temperature-dependent response is instantaneous and devoid of dissolved O2 and chlorophyll interferences. The sensor has been tested in a real-world environment for 11 days with good performance.

28 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YKYa Jie Knöbl
Ya Jie Knöbl
LJLauren M. Johnston
Lauren M. Johnston
JQJose Quilez
Jose Quilez
Guillermo OrellanaGuillermo Orellana
Guillermo Orellana
Water conductivity sensing relies universally on electrical measurements, which are subject to corrosion of the electrodes and subsequent signal drift in prolonged in situ uses. Furthermore, they cannot provide contactless sensing or remote readout. To this end, a novel device for water conductivity monitoring has been developed by employing a microenvironment-sensitive ruthenium complex, [Ru(2,2′-bipyridine-4,4′-disulfonato)3]4−, embedded into a quaternary ammonium functionalized cross-linked polymer support. The degree of swelling of the latter, which leads to a change in the emission lifetime, depends on the water conductivity. The sensor displays a reversible response (2 min ≤ t90 ≤ 3 min) and has been shown to be stable for >65 h of continuous monitoring of 0.8–12.8 mS cm−1 KCl solutions. Changes to the cation do not affect the sensor response, while changes to the anion type induce small effects. Variations in the dissolved O2 or temperature require corrections of the response. The sensor can be interrogated alongside dissolved O2 and pH luminescent sensors based on the same family of indicator dyes to exploit the definite advantages of luminescence lifetime-based detection.

8 July 2026 in Soil Biology and Biochemistry
Verified
Journal Article
Open access
PRPauline Sophie Rummel
Pauline Sophie Rummel
YKYa Jie Knöbl
Ya Jie Knöbl
MRMartin Reinhard Rasmussen
Martin Reinhard Rasmussen
KKKlaus Koren
Klaus Koren
AKAndrey V. Kalinichev
Andrey V. Kalinichev