Sayed Behzad Talaeitaba

Dr. Sayed Behzad Talaeitaba


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2019 in International Journal of Advanced Structural Engineering
Verified
Journal Article
Open access
PDF file
MSMajid Saedniya
Majid Saedniya
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
The ideal performance of seismic isolating systems during the past earthquakes has proved them to be very useful in protecting structures against earthquakes. The cyclic loading experimental tests are an important part in the process of completing the design of the isolators, yet they are very expensive and time consuming. Using the accurate analytical modeling of hysteresis tests and knowing the limitations and the amount of error of the finite elements model and its effect on designing the isolated structure make it possible to reduce the financial and time expenses involved in designing seismic isolators along with experimental tests. In the present study, the cyclic loading of two different isolating systems, namely, the high damping rubber bearing (HDRB) and lead rubber bearing (LRB) have been modeled and analyzed in ABAQUS and the outcomes were compared with the experimental results attained by other researchers. Regarding the fact that the most important and complicated component of the elastomeric isolating system is rubber, it was modeled using various strain energy functions. Other factors affecting the finite elements models of elastomeric isolators were also studied. After comparing the effective stiffness of the experimental sample with the analytical model of HDRB, the Yeoh function had the best performance in determining the effective stiffness of the isolating system with an error of less than 7%. In studying LRBs, too, three types of bearings with different dimensions and lateral strain values were studied; the polynomial function in shear strain value of 150% had the best performance in estimating effective stiffness and damping with errors of less than 3% and 18%, respectively.

18 February 2019 in International Journal of Advanced Structural Engineering
Verified
Journal Article
Open access
PDF file
RARojin Azizi
Rojin Azizi
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
The main objective of this study is strengthening of flat slabs in punching shear with a new model. For this purpose 15 numerical samples include a control and 14 strengthened defined and nonlinearly analyzed up to failure. The strengthening method is new method of grooving in two orthogonal direction (x and y axes of slab plan) and then mounting the external bars (sticking) in one direction and FRP in EBROG (externally bonded reinforcement on groove) method in another direction. The results showed the great efficiency of the method so that the punching shear capacity of strengthened samples increased between 28 and 62% compare to control one. Also the mode of failure changed in strengthened specimens from shear to flexure–shear and the punching critical area was broader and developed from the loading point. In the grooving method the sticking bars yielded in all specimens and the FRP tensile strain was closer to rupture strain compared to EBR.

5 October 2019 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
EBEhsan Barati
Ehsan Barati
AEAbolfazl Eslami
Abolfazl Eslami
This experimental study focuses on the retrofitting of reinforced concrete columns subjected to axial compression loading with different eccentricities. The proposed hybrid retrofitting technique incorporates two components: near-surface-mounted longitudinal steel rebars and transverse carbon-fiber-reinforced polymer straps. The latter was implemented to preclude buckling of the near-surface-mounted steel rebars under compression, to postpone debonding of near-surface-mounted steel rebars, to increase shear capacity of columns, and to improve the confinement level of concrete. The efficiency of the adopted retrofitting technique was evaluated through experimental testing of undamaged and damaged columns. Toward this, a total of 20 small-scale reinforced concrete circular columns including 5 control, 5 repaired, and 10 strengthened specimens were tested. All specimens were built to be identical with a diameter of 150 mm and a height of 500 mm. The specimens were tested under pure compression, combined axial–flexural (with eccentricities of 30, 60, and 90 mm), and four-point flexural loadings. Comparison of the results showed the efficacy of the proposed retrofitting strategy in enhancing the structural performance of both the undamaged and damaged columns in terms of loading capacity, ultimate displacement, and ductility factor. Finally, the axial load–bending moment interaction curves were discussed for all the tested columns.

28 November 2018 in Asian Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
MPMohammad Masoud Pourmasoud
Mohammad Masoud Pourmasoud
MJMilad Jabbari
Milad Jabbari

25 April 2025 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
Verified
Journal Article
Closed access
PDF file
RZReza Zamani
Reza Zamani
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
DMDavood Mostofinejad
Davood Mostofinejad

5 August 2021 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
STSayed Behzad Talaeitaba
Sayed Behzad Talaeitaba
FKFarshid Khamseh
Farshid Khamseh
MTMohammad Ebrahim Torki
Mohammad Ebrahim Torki