Robert Miller

Dr. Robert Miller


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2020 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
EEEvann Eisenberg
Evann Eisenberg
PMPriscilla A. McElhinney
Priscilla A. McElhinney
FCFrederic Commandeur
Frederic Commandeur
XCXi Chen
Xi Chen
SCSebastien Cadet
Sebastien Cadet
DDDamini Dey
Damini Dey
Background: Epicardial adipose tissue (EAT) volume (cm 3 ) and attenuation (Hounsfield units) may predict major adverse cardiovascular events (MACE). We aimed to evaluate the prognostic value of fully automated deep learning-based EAT volume and attenuation measurements quantified from noncontrast cardiac computed tomography. Methods: Our study included 2068 asymptomatic subjects (56±9 years, 59% male) from the EISNER trial (Early Identification of Subclinical Atherosclerosis by Noninvasive Imaging Research) with long-term follow-up after coronary artery calcium measurement. EAT volume and mean attenuation were quantified using automated deep learning software from noncontrast cardiac computed tomography. MACE was defined as myocardial infarction, late (>180 days) revascularization, and cardiac death. EAT measures were compared to coronary artery calcium score and atherosclerotic cardiovascular disease risk score for MACE prediction. Results: At 14±3 years, 223 subjects suffered MACE. Increased EAT volume and decreased EAT attenuation were both independently associated with MACE. Atherosclerotic cardiovascular disease risk score, coronary artery calcium, and EAT volume were associated with increased risk of MACE (hazard ratio [95%CI]: 1.03 [1.01–1.04]; 1.25 [1.19–1.30]; and 1.35 [1.07–1.68], P <0.01 for all) and EAT attenuation was inversely associated with MACE (hazard ratio, 0.83 [95% CI, 0.72–0.96]; P =0.01), with corresponding Harrell C statistic of 0.76. MACE risk progressively increased with EAT volume ≥113 cm 3 and coronary artery calcium ≥100 AU and was highest in subjects with both ( P <0.02 for all). In 1317 subjects, EAT volume was correlated with inflammatory biomarkers C-reactive protein, myeloperoxidase, and adiponectin reduction; EAT attenuation was inversely related to these biomarkers. Conclusions: Fully automated EAT volume and attenuation quantification by deep learning from noncontrast cardiac computed tomography can provide prognostic value for the asymptomatic patient, without additional imaging or physician interaction.

1 December 2019 in Cardiovascular Research
Verified
Journal Article
Open access
PDF file
FCFrederic Commandeur
Frederic Commandeur
PSPiotr J Slomka
Piotr J Slomka
MGMarkus Goeller
Markus Goeller
XCXi Chen
Xi Chen
SCSebastien Cadet
Sebastien Cadet
DDDamini Dey
Damini Dey
Our aim was to evaluate the performance of machine learning (ML), integrating clinical parameters with coronary artery calcium (CAC), and automated epicardial adipose tissue (EAT) quantification, for the prediction of long-term risk of myocardial infarction (MI) and cardiac death in asymptomatic subjects. Our study included 1912 asymptomatic subjects [1117 (58.4%) male, age: 55.8 ± 9.1 years] from the prospective EISNER trial with long-term follow-up after CAC scoring. EAT volume and density were quantified using a fully automated deep learning method. ML extreme gradient boosting was trained using clinical co-variates, plasma lipid panel measurements, risk factors, CAC, aortic calcium, and automated EAT measures, and validated using repeated 10-fold cross validation. During mean follow-up of 14.5 ± 2 years, 76 events of MI and/or cardiac death occurred. ML obtained a significantly higher AUC than atherosclerotic cardiovascular disease (ASCVD) risk and CAC score for predicting events (ML: 0.82; ASCVD: 0.77; CAC: 0.77, P < 0.05 for all). Subjects with a higher ML score (by Youden’s index) had high hazard of suffering events (HR: 10.38, P < 0.001); the relationships persisted in multivariable analysis including ASCVD-risk and CAC measures (HR: 2.94, P = 0.005). Age, ASCVD-risk, and CAC were prognostically important for both genders. Systolic blood pressure was more important than cholesterol in women, and the opposite in men. In this prospective study, machine learning used to integrate clinical and quantitative imaging-based variables significantly improves prediction of MI and cardiac death compared with standard clinical risk assessment. Following further validation, such a personalized paradigm could potentially be used to improve cardiovascular risk assessment.

2 August 2019 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PSPiotr J. Slomka
Piotr J. Slomka
RMRobert Miller
Robert Miller
LHLien-Hsin Hu
Lien-Hsin Hu
GGGuido Germano
Guido Germano
DBDaniel S. Berman
Daniel S. Berman
There has been an evolutionary leap in SPECT imaging with the advent of camera systems that use solid-state crystals and novel collimator designs configured specifically for cardiac imaging. Solid-state SPECT camera systems have facilitated dramatic reductions in both imaging time and radiation dose while maintaining high diagnostic accuracy. These advances are related to simultaneous improvement in photon sensitivity due to the collimator and imaging geometry, as well as image resolution due to the improved energy resolution of the new crystals. Improved photon sensitivity has facilitated fast or low-dose myocardial perfusion imaging (MPI), and early dynamic imaging has emerged as a technique for assessing myocardial blood flow with SPECT. Lastly, general-purpose solid-state camera systems and hybrid SPECT/CT systems have also been developed that may have important clinical roles in cardiac imaging. This review summarizes state-of-the-art solid-state SPECT MPI technology and clinical applications, including emerging techniques for SPECT MPI flow estimation. We also discuss imaging protocols used with the new cameras, potential imaging pitfalls, and the latest data providing large-scale validation of the diagnostic and prognostic value of this new technology.

14 September 2022 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
KPKonrad Pieszko
Konrad Pieszko
ASAakash Shanbhag
Aakash Shanbhag
AKAditya Killekar
Aditya Killekar
RMRobert Miller
Robert Miller
MLMark Lemley
Mark Lemley
PSPiotr J. Slomka
Piotr J. Slomka

12 April 2016 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
RMRobert Miller
Robert Miller
BCBarbara Chow
Barbara Chow
DPDylan Pillai
Dylan Pillai
DCDeirdre Church
Deirdre Church
The study aimed to explore the sensitivity and specificity of a novel fast 16S rDNA PCR and sequencing assay for the improved diagnosis of infective endocarditis (IE) in patients with suspected native or prosthetic heart valve (HV) infection over a multi-year period at our cardiovascular center. Sixty-eight patients were prospectively enrolled who underwent HV replacement for suspected or confirmed IE between February 1, 2009 and September 1, 2014. Patient demographics, medical co-morbidities, Duke’s criteria, culture results, and antibiotic therapy were collected by detailed chart reviews. Dual-priming oligonucleotide primers targeted to 500 bps of the V1-V3 region of the 16S rRNA gene were used to perform fast broad-range 16S rDNA PCR and Sanger sequencing on ribosomal DNA extracted from HV tissues. The performance/diagnostic efficiency of the molecular test was evaluated against blood cultures and Gram stain and culture of HV tissue in patients’ with definite IE according to Duke’s criteria. Fifty patients (73.5 %) had definite IE and another 8 (11.8 %) had possible IE according to Duke’s criteria. Cardiac surgery was delayed an average of 15.4 days from the time of the patient’s last positive blood culture, and appropriate antibiotic therapy was given in the pre-operative period. While 44/50 (88 %) patients had a positive blood culture, HV tissue culture was only positive in 23 (46 %) of them. Molecular testing of all HV tissues had sensitivity, specificity, NPV and PPV of 92, 77.8, 77.8 and 92 % compared to 44, 100, 39.1 and 100 % respectively for culture for diagnosis of definite IE. For prosthetic HV tissue, 16S rDNA PCR had sensitivity of 93 % and specificity of 83 % compared to 35 and 100 % respectively for culture. A literature review showed that the diagnostic accuracy of our novel fast broad-range 16S rDNA PCR assay was similar or better than that of previously published studies. This novel fast broad-range 16S rDNA PCR/sequencing test had superior sensitivity compared to tissue Gram stain and culture for identifying underlying bacterial pathogen in both native and prosthetic valve endocarditis.

25 March 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
RRRichard Rios
Richard Rios
RMRobert Miller
Robert Miller
NMNipun Manral
Nipun Manral
TSTali Sharir
Tali Sharir
AEAndrew J. Einstein
Andrew J. Einstein
PSPiotr J. Slomka
Piotr J. Slomka