The purpose of the article was to present information on heat recovery in ventilation systems and to highlight what has not been sufficiently researched in this regard. A lot of information can be found on methods and exchangers for heat recovery in centralized systems. Decentralized, façade systems for cyclical supply and exhaust air have not been sufficiently researched. It is known that these devices are sensitive to the influence of wind and temperature, hence heat recovery may be ineffective in their case. The literature describes the aspect of heat recovery depending on the location in climatic zones, depending on the number of degree days (HDD). Attention was also paid to the risk of freezing of heat recovery exchangers. The literature review also showed the lack of a universal method for assessing heat recovery exchangers and the method of their selection depending on the climate.
The study contains an analysis of a decentralised unit installed in a building façade, where air supply and exhaust cycles are swapped by proper positioning of dampers. The analysis was carried out in real conditions in an office building. The Computational Fluid Dynamics (CFD) simulation is an important element of the system design, and has become more and more widely used. Simulation of the analysed unit has shown air stream distribution in a room. Moreover, it allowed for determination of indoor air temperature. Completed analysis and CFD simulations allow for the observation that façade ventilation systems provide a good way to improve the indoor microclimate, as they effectively reduce air pollution. The decentralised façade ventilation unit reduced the carbon dioxide concentration to a level lower than 1000 ppm and maintained the indoor air temperature in the range of 19.5–22 °C. The error for CFD simulation equals 0.5%, which is not much. The results of research and analysis show that the highest reduction of carbon dioxide concentration occurred when supply/exhaust time equalled 10 min. At the same time, when supply/exhaust time equalled 10 min, the indoor air temperature was the lowest of the recorded values.
Due to the spread of the SARS-CoV-2 virus, most countries have tightened their public health policies. One way to limit the spread of the virus is to make mouth and nose cover compulsory in public spaces. The article presents the impact of wearing masks on the perception of thermal comfort. The following masks were analysed: FFP2, cotton, medical, PM2.5, half-face protective shield plastic and full-face protective shield plastic. The research was carried out for two scenarios of an ambient temperature: −20 and 30 °C. A thermal manikin was used for the tests. In the case of when a temperature equals 20 °C, the dry masks increase comfort, both general and local, while wet masks reduce comfort. On the other hand, at 30 °C, only wet masks do not increase discomfort. In addition, moist masks require less heat flux to achieve a certain skin temperature. However, it should be remembered that it is not advisable to wet the masks from the health point of view.
This paper presents the results of the investigation devoted to the quality of indoor air in classrooms of selected Polish kindergartens. The kindergartens buildings were built between 1970 and 1993 and had gravity ventilation systems. The variability of basic IAQ parameters. The outcomes confirmed low quality of the indoor air in these buildings. Certain modifications aimed at improving IAQ were proposed during the investigations. Two solutions were implemented: twofold increase in the volume of supply air and installing indoor air cleaning devices based on the radiant catalytic ionization technology (RCI)
24 July 2017 in International Journal of Environmental Science and Technology
Indoor air quality attracts great interest. Many dwellings are ventilated naturally. The article presents the gravity system conversion into individual air supply system, which can be equipped with air fan. This solution’s impact on the interior microclimate was analyzed. The proposed solution uses the lower natural ventilation ducts sections, which are not normally used as air supply channels to bring air to the housing. Exhaust grilles were located in the adjacent rooms. Individual air supply system with switched off fan improves indoor air quality insufficiently; however, switching on the device causes a very significant change. A large carbon dioxide concentration reduction (which was used as an air quality indicator) has been confirmed by rigorous statistical analysis, the results of which were presented in the article.