Camilla Pagnacco

Dr. Camilla Pagnacco

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EPEmilio Pedrotti
Emilio Pedrotti
EBErika Bonacci
Erika Bonacci
RKRaphael Kilian
Raphael Kilian
CPCamilla Pagnacco
Camilla Pagnacco
AFAdriano Fasolo
Adriano Fasolo
GMGiorgio MARCHINI
Giorgio MARCHINI
The aim of this prospective explorative study was to evaluate the safety and the effectiveness of topical polyvinylpyrrolidone-iodine (PVP-I) administered during the time-to-results period for pathogen identification and susceptibility testing in patients with infectious keratitis (IK). A corneal swab (CS) for antimicrobial evaluation was performed at enrollment (T0) and topical 0.66%-PVP-I was administered until the laboratory results were available (T1). Ulcer and infiltrate areas and infiltrate depths were compared between T0 and T1 (i.e., time-to-result period). Patients were then shifted to a specific antimicrobial therapy and followed up until resolution of their infiltrates (Tlast-TL). Twenty-five eyes were enrolled, and none showed clinical worsening leading to protocol withdrawal. At T1, ulcer and infiltrate areas showed significant improvement in Gram-positive IK (n = 13–52%; p = 0.027 and p = 0.019, respectively), remained stable in fungal IK (n = 5–20%; both p = 0.98) and increased in those with Gram-negative bacteria (n = 4–16%; p = 0.58 and p = 0.27). Eyes with negative cultures (n = 3–12%) showed complete resolution at T1 and did not initiate any additional antimicrobial therapy. The administration of 0.66% PVP-I during the time-to-result period seems to be a safe strategy in patients with IK while often sparing broad-spectrum antimicrobial agents. In addition, it showed to be effective in eyes with a Gram-positive bacterial infection.

6 March 2023 in Frontiers in Medicine
Verified
Journal Article
Open access
EPEmilio Pedrotti
Emilio Pedrotti
EBErika Bonacci
Erika Bonacci
RKRaphael Kilian
Raphael Kilian
CPCamilla Pagnacco
Camilla Pagnacco
MAMarco Anastasi
Marco Anastasi
GMGiorgio Marchini
Giorgio Marchini
Purpose: To analyze the objective and subjective visual performances of a new hybrid refractive/aspheric extended depth of focus (EDOF) intraocular lens (IOL).Methods: In this monocentric prospective study patients with bilateral cataracts underwent cataract surgery and were implanted with a Lucidis IOL (SAV-IOL SA, Neuchâtel, Switzerland) in both eyes, 1 week apart from each other. At 3 months from implantation postoperative evaluations included monocular and binocular uncorrected and distance-corrected distant (4 m), intermediate (80 cm, 67 cm) and near (40 cm) visual acuities (UDVA/DCVA, UI80-67VA/DCI80-67VA, UNVA/DCNVA), binocular defocus curves, halometry, contrast sensitivity and objective quality-of-vision measurements. Also, patients were also asked to complete the national eye institute refractive error quality of life (NEI-RQL-42) questionnaire.Results: Twenty-five patients (50 eyes) were included. The mean postoperative binocular UDVA, UI80VA, UI67VA and UNVA were-0.02 ± 0.13, 0.05 ± 0.09, 0.05 ± 0.08 and 0.03 ± 0.1 LogMar, and did not significantly differ from their corrected counterparts. On binocular defocus curves a VA ≥0.05LogMar was found between +0.50 and − 2.50 D of vergence, whereas the mean distance from the central stimulus on halometry was 1.23 ± 0.01. Mean ocular and corneal radical mean square at 4 mm were 0.31 ± 0.28 and 0.19 ± 0.07, respectively; whereas the mean Strehl ratio was 0.2 ± 0.09.Conclusion: Lucidis IOLs demonstrated excellent visual performances, especially at close distances while maintain good quality of vision, contrast sensitivity, and overall patient-satisfaction.

26 February 2025 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
EBErika Bonacci
Erika Bonacci
CPCamilla Pagnacco
Camilla Pagnacco
MAMarco Anastasi
Marco Anastasi
AGAlessandra De Gregorio
Alessandra De Gregorio
GMGiorgio MARCHINI
Giorgio MARCHINI
EPEmilio Pedrotti
Emilio Pedrotti
Objective: To evaluate visual outcomes, rotational stability, patients’ satisfaction, and spectacle independence after bilateral Toric extended depth of focus intraocular lens (EDOF IOL) implantation. Methods: Prospective observational study including cataract patients with bilateral corneal astigmatism between 0.75 and 3.00 D implanted with Toric EDOF IOLs. After three months distance corrected and uncorrected visual acuity at 4 m (DCVA and UDVA), 80 cm (DCI80VA and UI80VA), 67 cm (DCI67VA and UI67VA), and 40 cm (DCNVA and UNVA), IOL stability by Toric IOL Assistant tool (Osiris T, CSO, Florence, Italy), binocular defocus curves, contrast sensitivity (CS), halometry, reading performance, and subjective and objective (Root mean square-RMS, modulation transfer function-MTF, cut-off and point-spread-function-PSF-Strehl ratio) visual quality were evaluated. Results: Forty eyes from 20 astigmatic patients were enrolled. Mean refractive spherical equivalent and residual cylinder were −0.21 ± 0.74 D and 0.29 ± 0.31 D, respectively. No patients needed additional surgery due to IOL rotation. Binocular UDVA, UI80VA, UI67VA, and UNVA ≤ 0.2 logMAR was found in 90%, 95%, 85%, and 80%. Distance-corrected visual outcomes have overall shown higher performances. All visual acuities at defocus curves were ≤0.125 logMAR between +0.50 D and −2.00 D. PSF-Strehl ratio, MTF cut-off, RMS were 0.26 ± 0.28, 19.82 ± 12.35, 0.31 ± 0.17. Reading analysis reached 125.42 ± 27.21 words/minute, 92.56 ± 7.82, 0.17 ± 0.15 logMAR and 0.50 ± 0.11 logRAD for mean reading speed, visual acuity score, reading acuity, and critical print size, respectively. CS was higher in photopic conditions. Subjective spectacle independence was achieved in 80% of patients. Conclusions: Toric EDOF IOL showed rotational stability and reliable astigmatic correction. It provided spectacle independence and good performance from distance to near distance, reaching high patient satisfaction without undermining binocular quality of vision.

29 October 2024 in Cornea
Verified
Journal Article
Closed access
EBErika Bonacci
Erika Bonacci
AFAdriano Msc Fasolo
Adriano Msc Fasolo
CPCamilla Pagnacco
Camilla Pagnacco
FBFrancesca Bosello
Francesca Bosello
GMGiorgio Marchini
Giorgio Marchini
EPEmilio Md Pedrotti
Emilio Md Pedrotti
Purpose: To manage ocular surface complications and recover conjunctival and corneal epithelia after unilateral severe chemical burn. Methods: We performed simple conjunctival epithelial transplantation (SCET) to obtain renewal of fornix and bulbar-tarsal conjunctiva epithelium, followed by simple limbal epithelial transplantation (SLET) to recover limbal function and epithelial corneal surface. Slit-lamp examination, fluorescein staining, in vivo confocal microscopy, Kheirkhah grading system for symblepharon severity, Wong–Baker FACES Pain Rating Scale, and best-corrected visual acuity were assessed before surgery, at 1 to 3 months after SCET and SLET, and thereafter at 6 to 12 to 36 months. Results: Two patients with unilateral burn injuries underwent surgery. Eye mobility and fornix reconstruction were promptly achieved, and conjunctival epithelium with goblet cells was observed on the bulbar and tarsal conjunctiva 3 months after SCET. After SLET, corneal epithelium and cornea-conjunctiva transition zone were observed at 3 and 6 months, respectively. From before surgery to 6 months after SLET, symblepharon improved from grade IVa2 and IIIb2 to Ic0 and Ib0, the Wong–Baker FACES Pain Rating Scale changed from grade 6 and 4 to 0, and best-corrected visual acuity upgraded from 1.40 and 1.10 logarithm of the minimum angle of resolution to 0.5 logarithm of the minimum angle of resolution, in patient 1 and 2, respectively. After 3 years, results remained stable. Conclusions: SCET effectively healed the bare conjunctival area relieving subjective symptoms and discomfort. Sequential SCET and SLET showed to be feasible in restoring a normal ocular surface with long-lasting results suggesting the aim in patients with severe ocular burn is not merely corneal epithelium renewal but also the regeneration of ocular surface homeostasis.

1 October 2024 in Journal of Ocular Pharmacology and Therapeutics
Verified
Journal Article
Closed access
CPCamilla Pagnacco
Camilla Pagnacco
RTRoberto Tosi
Roberto Tosi
JDJessica Dalsaso
Jessica Dalsaso
SFSebastiano Fraccaroli
Sebastiano Fraccaroli
FSFilippo Saggin
Filippo Saggin
GMGiorgio Marchini
Giorgio Marchini
Purpose: To protect the corneal endothelium, various ophthalmical viscoelastic devices (OVDs) are used during cataract surgery. In this study, we compared two sodium hyaluronate-based OVD, the bacteria-derived FIDIAL PLUS OVD (test) with the animal-derived IAL ® -F OVD (reference) during the surgical procedure. Methods: Fifty patients with bilateral cataract participated in the study: 50 eyes randomly received FIDIAL PLUS and 50 eyes received IAL ® -F (ratio 1:1). Noninferior efficacy of FIDIAL PLUS compared with reference OVD (first objective) was evaluated using a paired t -test comparing the mean percent loss of corneal endothelial cells (CECs) with FIDIAL PLUS against the mean percent loss with IAL ® -F. Corneal endothelial protection during cataract surgery with FIDIAL PLUS without significant (≥30 mmHg) postoperative intraocular pressure (IOP) increase (main secondary objective) was assessed using a repeated measures logistic model comparing the incidence of significant postoperative IOP elevation between the two groups. Safety, tolerability, and efficacy were also evaluated by assessing secondary endpoints before and after surgery. Results: FIDIAL PLUS showed a statistically noninferior efficacy compared with IAL ® -F; there was no significant increase in IOP in either group or different trends of the secondary endpoints were observed between the OVD groups. The safety profile was similar in both OVD groups and no adverse device effects were reported. Conclusions: This study demonstrates the equivalent efficacy, tolerability, and safety of the bacteria-derived FIDIAL PLUS compared with the animal-derived IAL ® -F, confirming the clinical value of this product.

4 August 2026 in International Ophthalmology
Verified
Journal Article
Open access
PDF file
EBErika Bonacci
Erika Bonacci
CPCamilla Pagnacco
Camilla Pagnacco
AFAdriano Fasolo
Adriano Fasolo
FBFrancesca Barzaghi
Francesca Barzaghi
ABAriel Bonato
Ariel Bonato
EPEmilio Pedrotti
Emilio Pedrotti
Aims: To evaluate visual performance, contrast sensitivity (CS), optical quality, and subjective satisfaction of Vivity extended depth-of-focus (EDOF) premium intraocular lens (pIOL) in early keratoconus (KC). Methods: In this prospective, interventional, single-center clinical study, ten patients with mild bilateral KC and cataract received AcrySof IQ Vivity pIOL. Pre- and postoperative assessments included monocular and binocular uncorrected and distance-corrected visual acuities at 4 m (UDVA, DCVA), uncorrected and distance-corrected intermediate and near visual acuities at 66 cm (UI66VA, DCI66VA) and 40 cm (UNVA, DCNVA), defocus curve, CS, wavefront aberrometry (RMS, PSF, Strehl ratio), halometry, and subjective outcomes. Results: At 3 months, mean ± SD monocular DCVA in the dominant eyes (primary endpoint) was 0.06 ± 0.13 logMAR. A statistically significant improvement was observed between preoperative and postoperative monocular and binocular UDVA, UNVA, DCNVA ( p < 0.001), and DCVA ( p = 0.03). Binocular DCI66VA and UI66VA were 0.10 ± 0.15 and 0.14 ± 0.16 logMAR, respectively. The defocus curve was ≤ 0.20 logMAR from + 0.50 D to – 2.00 D. CS peaked under scotopic conditions at 6 cpd, total ocular RMS improved from 2.15 ± 1.98 to 1.09 ± 0.77 ( p = 0.09). NEI-RQL-42 scores indicated favourable patient-reported outcomes, particularly for glare, clarity of vision, and satisfaction with correction. Conclusion: In this small prospective pilot study, bilateral implantation of a non-diffractive EDOF IOL was associated with favourable short-term visual outcomes in highly selected patients with stable early keratoconus. These preliminary findings suggest that early stable KC may not represent an absolute contraindication to non-diffractive EDOF IOL implantation, but larger comparative studies with longer follow-up are required.