Bacterial infection is one of the most frequent complications in the burn and chronic wounds. Inspired by natural existing superhydrophobic surface structures, a novel asymmetric wettable membrane was prepared using the electrospinning technique for facilitating the bacteria-infected wound healing. Herein, the prepared membrane consist of two layers: the hydrophobic outer layer was composed of poly (lactic-co-glycolic) acid (PLGA) and black phosphorus grafted chitosan (HACC-BP), while the hydrophilic inner layer was composed by using a mixture of gelatin (Gel) with ginsenoside Rg1 (Rg1). Biological studies in vitro showed BP@PLGA/Gel (BP@BM) membrane with excellent antibacterial activity could significantly inhibit the adhesion of bacteria, and Rg1 could facilitate the migration and tube formation of human umbilical vein endothelial cells (HUVECs). Compare to Aquacel Ag dressing, the result in vivo revealed that the Rg1/BP@BM could facilitate better wound healing by triggering phosphoinositide 3-kinase (P-PI3K/PI3K) and phosphorylation of protein kinase B (P-AKT/AKT) signaling pathways, upregulating Ki67, CD31, α-SMA and TGF-β1, and downregulating TNF-α, IL-1β and IL-6, promoting M2 polarization (IL-10, CD206 and Arg-1) of macrophages, inhibiting M1 polarization (iNOS) of macrophages. These findings suggested that the asymmetric wettable membrane have the huge potential for wound healing.
7 January 2023 in Journal of Cardiothoracic Surgery
Pure aortic valve disease is common and has been treated with sternotomy aortic valve replacement for decades. Minimally invasive cardiac surgery has been widely used in atrioventricular valve lesions, but totally thoracoscopic aortic valve replacement has rarely been reported. The profiles of 9 patients who were diagnosed with severe aortic valve diseases and treated with two-port thoracoscopic aortic valve replacement between February 2021 and February 2022 were retrospectively reviewed. The clinical data, including baseline characteristics, operative data, postoperative complications, and short-term outcomes, were reported. All nine patients successfully underwent two-port thoracoscopic aortic valve replacement, with a cardiopulmonary bypass time of 137.56 ± 27.99 min and an aortic cross-clamp time of 95.33 ± 17.96 min. Seven (77.78%) patients underwent mechanical valve replacement, and two (22.22%) patients underwent bioprosthetic valve replacement. Two (22.22%) patients underwent a concomitant aortic root enlargement procedure. There were no intraoperative or postoperative deaths. The incidence of procedural complications was 0%, while the results of ventilation time, intensive care unit stay length, blood transfusion, chest tube drainage, and kidney function were satisfactory. Two-port thoracoscopic aortic valve replacement is a safe and effective surgical treatment option for carefully selected patients with pure aortic valve diseases.
25 April 2023 in Journal of Cardiothoracic Surgery
Objectives: To compare the safety and efficacy of del-Nido cardioplegia (DNC) with traditional 4:1 cold blood cardioplegia (CBC) in coronary artery bypass grafting and/or valve surgeries in elderly patients.Methods: The present study is a retrospective case-series study that included 302 consecutive patients aged 70 years and over who underwent on-pump valve surgery and/or coronary artery bypass graft (CABG). DNC was administered to 90 patients and CBC to 212 patients. After propensity-score matching, 89 pairs were compared. The safety and efficacy were analyzed between the two groups.Results: The DNC group had a similar mortality (3.4% vs. 5.6%, OR = 0.79,P = 0.720) and extracorporeal membrane oxygenation (ECMO) implantation rate (1.1% vs. 2.2%, OR = 0.75,P = 1.000) to the CBC group, a lower incidence of postoperative intra-aortic balloon pump (IABP) implantation (1.1% vs. 9.0%, OR = 0.54,P = 0.034) and a higher left ventricular ejection fraction (LVEF) at discharge (60 (56–64) % vs. 57 (51–62)%,P = 0.007). The estimated glomerular filtration rate (eGFR) in the DNC group was higher when the patient was transferred to the intensive care unit (79.4 (65.0-94.3) ml/min/1.73m2vs. 77.2 (59.8–88.7) ml/min/1.73m2,P = 0.014), but no significant differences were identified after 24 h. The serum lactate values of the DNC group were significantly lower than those of the CBC group (0 h: 2.7 (2.0-3.2) vs. 3.2 (2.4–4.4),P = 0.001; 3 h: 3.2 (2.0-4.8) vs. 4.8 (2.8–6.6),P < 0.001; 6 h: 3.5 (2.2–5.4) vs. 5.8 (3.4–8.4),P < 0.001; 9 h: 3.4 (2.0–7.0) vs. 5.5 (2.9–8.3),P = 0.005). There were no differences between the two groups in respect of lactate levels at 12 h and thereafter. Postoperative creatinine kinase-MB concentrations were similar between the two groups.Conclusions: Del-Nido cardioplegia is safe and effective in elderly patients undergoing CABG and/or valve surgery.
Background: Failed mitral bioprosthesis has conventionally been treated with redo surgical mitral valve replacement (SMVR). Transcatheter mitral valve-in-valve implantation (TM-VIVI) is emerging as an alternative to SMVR in high-risk patients. We report our experience with transapical TM-VIVI using the J-Valve system. Methods: From May 2020 to January 2021, 21 patients with a failed mitral bioprosthesis underwent transapical TM-VIVI without concomitant procedures at Guangdong Provincial People’s hospital. The mean age was 74.62 years. All patients were heavily symptomatic with severe mitral regurgitation and increased trans-prosthetic gradient. The Society of Thoracic Surgeons predicted risk of mortality (STS PROM) and European System for Cardiac Operative Risk Evaluation II (EuroScore II) scores were used and predicted high mortality (STS PROM, 12.91%±9.94%; EuroScore II, 12.04%±10.5%). All the procedures were performed in a hybrid room. Results: The success rate was 100% with no conversion to median sternotomy and no intraprocedural death. The mean ventilation time and intensive care unit (ICU) stay were 25±21.44 minutes and 4.14±7.08 days, respectively. No major postoperative complications were observed, except 1 patient suffered pneumonia and required tracheostomy. All patients recovered well. Postoperative echocardiography revealed excellent hemodynamics with no residual mitral regurgitation in 19 patients and mild regurgitation in 2 patients. In a subgroup analysis, no significant differences among procedural and postoperative outcomes were detected in patients with previous aortic-mitral double valve replacement (DVR) compared to other patients. Conclusions: Our results demonstrate the safety and feasibility of transapical TM-VIVI using the J-Valve system, even in patients following DVR.
Background: This study aimed to summarize the perioperative and long-term outcomes of patients with previous mitral valve surgery (MVS) undergoing reoperative mitral valve replacement (MVR). Methods: Data for all reoperative mitral valve replacements (re-MVRs) with or without concomitant tricuspid surgery were analyzed from Guangdong Provincial People’s Hospital between January 2013 and December 2019. Propensity score matching resulted in 30 matched pairs with improved balance after matching in baseline covariates. Perioperative data and long‐term clinical outcomes were analyzed. Results: Results are based on the matched cohorts between the two groups. The in-hospital mortality was 3.3% (two deaths) in the entire cohort and was not significantly different between the median sternotomy (MS) group and the totally thoracoscopic (TT) group. Most patients in the TT group had their tracheal intubation removed within 24 hours of surgery. The TT group had a diminished requirement for blood transfusion and a reduced 4-day postoperative chest tube drainage amount. The incidence of early major complications, including all-cause death and reoperation due to bleeding, was lower in the TT group. No significant differences were observed in the 7-year survival probability between the two groups. Conclusions: The encouraging results regarding the perioperative and long-term outcomes of patients who underwent a TT re-MVR show that this approach is particularly beneficial for patients requiring reoperation.
The wide adoption of the MitraClip procedure in clinical practice inevitably causes increases in surgical intervention demand for patients following failed MitraClip implantation. Current reports about surgical intervention after failed MitraClip procedure focused on open-heart surgery. In this case, totally thoracoscopic third-time redo mitral valve replacement was successfully performed for a high-risk patient, following aortic valve replacement and a failed MitraClip procedure.