Xingbin Lv

Dr. Xingbin Lv

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2024 in Separation and Purification Technology
Verified
Journal Article
Closed access
XLXingbin Lv
Xingbin Lv
RXRui Xie
Rui Xie
JJJun-Yi Ji
Jun-Yi Ji
PHPing He
Ping He
YYYi-Fan Yuan
Yi-Fan Yuan
LCLiang-Yin Chu
Liang-Yin Chu


15 September 2024 in Separation and Purification Technology
Verified
Journal Article
Closed access
XLXingbin Lv
Xingbin Lv
YZYanmei Zhu
Yanmei Zhu
YDYuping Du
Yuping Du
HMHaoran Ma
Haoran Ma
HZHe Zhang
He Zhang
JJJunyi Ji
Junyi Ji

26 December 2023 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
JWJingya Wen
Jingya Wen
XWXi Wang
Xi Wang
HYHairong Yu
Hairong Yu
XLXingbin Lv
Xingbin Lv
TLTing Liang
Ting Liang
CCChangjing Cheng
Changjing Cheng
Glucose detection plays a crucial role in the treatment and management of diabetes. We herein report a simple strategy to prepare a photonic crystal hydrogel (PNAPB PCH) sensor for colorimetric detection of glucose. This sensor is composed of a poly(N-isopropylacrylamide-co-3-acrylamidophenyl boronic acid) smart hydrogel with pendent phenylboronic acid (PBA) units and embedded Fe3O4 colloidal photonic crystals (PCs), which could strongly diffract visible light and endow the hydrogel with brilliant structural colors. The PBA units could form complexes with glucose molecules, thus increasing the ionization degree of the hydrogel and expanding its volume. The volume swelling increased the adjacent distance of the Fe3O4 nanoparticles (NPs) and thereby red-shifted their diffraction wavelength. As a result, the glucose signal could be facilely converted into a color change of the hydrogel. The resultant PNAPB PCH biosensor displayed high sensitivity and selectivity to glucose as well as excellent thermosensitive detection performances. In addition, by taking advantage of the unique thermosensitivity of the introduced PNIPAM moieties on the gel network, the glucose-responded PNAPB PCH sensor could be easily regenerated via simple alternate flushing using hot/cold water without compromising its performance. Such a glucose-sensitive PCH sensor possessing the obvious advantages of portability, ease of operation, and cost-effectiveness makes it valuable for daily blood glucose monitoring and diabetes diagnosis.


9 August 2025 in Separation and Purification Technology
Verified
Journal Article
Closed access
AAAyixiemiguli Atawula
Ayixiemiguli Atawula
YZYanmei Zhu
Yanmei Zhu
TYTao Yang
Tao Yang
YDYuping Du
Yuping Du
WMWanchao Ma
Wanchao Ma
CCChangjing Cheng
Changjing Cheng