Background: Osteoporosis is an independent risk factor for failure after arthroscopic rotator cuff repair. Since rerupture rates after rotator cuff repair are associated with decreased bone mineral density and bone microarchitecture, adaptations of biomechanical properties of the rotator cuff enthesis in patients with osteoporosis remain unclear. Additionally, the effects of osteogenic therapy carrier drugs used for the treatment of osteoporosis on rotator cuff structure and properties have not been previously documented. Purpose: To investigate the changes to soft tissue biomechanics and insertional structure secondary to osteoporosis with and without an osteogenic therapy carrier (ie, modified alendronate). Study Design: Controlled laboratory study. Methods: Biomechanical, histopathological, and microcomputed tomography analyses were performed on 20 shoulders obtained from 10 osteoporotic sheep randomly allocated to modified bisphosphonate (ie, alendronate) or control (ie, osteoporotic without treatment) groups; 6 shoulders from healthy sheep were utilized for comparison purposes. Results: Tendons from the control group exhibited a 57% decrease in undeformed Young modulus as compared with the healthy group ( P = .010). Tendons from the modified bisphosphonate treatment group exhibited a 229% increase in initial Young modulus as compared with the control group ( P = .010). Marked changes within the tendon insertional organization were noted in both the control and the modified bisphosphonate treatment group samples as evidenced by increased interdigitation of the bone–mineralized fibrocartilaginous junction. The control samples exhibited a markedly paucicellular insertion, whereas the modified bisphosphonate treated tendons exhibited a hypercellular insertional region as compared with the healthy group. Both groups exhibited significantly ( P < .01) decreased bone quality underlying the infraspinatus insertion, as evidenced by all microcomputed tomography outcome parameters. Conclusion: This work illuminates changes to rotator cuff tendon secondary to osteoporosis. Specifically, it revealed decreased tendon modulus and altered insertional structure in the osteoporotic samples. Secondarily, these data revealed increases in tendon modulus accompanied by increased cellularity within the tendon insertion region after systemic modified bisphosphonate injections. Clinical Relevance: Bisphosphonate treatment may have a positive effect on the healing of the enthesis after rotator cuff repair.
Background: Untreated rotator cuff tears lead to irreversible tendon degeneration, resulting in unacceptable repair prognosis. The inability of current animal models of degenerated rotator cuff tendons to more fully emulate the manifestation and degree of pathology seen in humans with a previously torn rotator cuff tendon (s) significantly impairs the development of novel therapeutics. Therefore, the objective of this study was to develop a large-animal translational model of enthesis damage to the rotator cuff tendons to mimic the chronic degenerative changes that occur in patients that demonstrate clinical manifestations of tendinopathy. Methods: A partial enthesis tear model (i.e., sharp transection) in adult sheep was created by cutting the tendon fibers perpendicularly through the enthesis midpoint, while leaving the other portion of the tendon in-tact. To assess tendon integrity, non-destructive biomechanical tests were performed, followed by histopathological, histomorphological, and gene expression analysis. Samples of degenerated human rotator cuff tendons obtained from patients undergoing reverse total shoulder arthroplasty to use for comparative pathological analysis. Results: In the sheep model, transected tendons at all timepoints had significantly decreased mechanical properties. Histopathologic evaluation and Bonar scoring revealed that the tendons in sheep underwent degenerative changes similar in magnitude and manifestation as the degenerated human tendon samples. Furthermore, similar levels of collagen disorganization were noted between the 6 and 12-week ovine samples and the degenerated human samples. Conclusions: These findings indicate that the new sheep model of rotator cuff injury reliably recapitulates the structural and cellular changes that occur clinically in humans with chronic rotator cuff tendon injuries and suggest that this new model is well suited to evaluation of new therapeutic interventions.
Background: The use of intervertebral cages within the interbody fusion setting is ubiquitous. Synthetic cages are predominantly manufactured using materials such as Ti and PEEK. With the advent of additive manufacturing techniques, it is now possible to spatially vary complex 3D geometric features within interbody devices, enabling the devices to match the stiffness of native tissue and better promote bony integration. To date, the impact of surface porosity of additively manufactured Ti interbody cages on fusion outcomes has not been investigated. Thus, the objective of this work was to determine the effect of implant endplate surface and implant body architecture of additive manufactured lattice structure titanium interbody cages on bony fusion.Methods: Biomechanical, microcomputed tomography, static and dynamic histomorphometry, and histopathology analyses were performed on twelve functional spine units obtained from six sheep randomly allocated to body lattice or surface lattice groups.Results: Nondestructive kinematic testing, microcomputed tomography analysis, and histomorphometry analyses of the functional spine units revealed positive fusion outcomes in both groups. These data revealed similar results in both groups, with the exception of bone‐in‐contact analysis, which revealed significantly improved bone‐in‐contact values in the body lattice group compared to the surface lattice group.Conclusion: Both additively manufactured porous titanium cage designs resulted in increased fusion outcomes as compared to PEEK interbody cage designs as illustrated by the nondestructive kinematic motion testing, static and dynamic histomorphometry, microcomputed tomography, and histopathology analyses. While both cages provided for similar functional outcomes, these data suggest boney contact with an interbody cage may be impacted by the nature of implant porosity adjacent to the vertebral endplates.
2 January 2024 in International Journal of Sports Physical Therapy
Background: Plantar fasciitis (PF) results in pain-related disability and excessive healthcare costs. Photobiomodulation therapy (PBMT) has shown promise for decreasing both pain and disability related to PF. Purpose: The purpose was to assess the clinical impact of PBMT on pain and function in people with PF. Study Design: Prospective, randomized controlled clinical trial Methods: A convenience sample of adults with PF were randomly assigned to one of three groups: (1) usual care, (2) usual care plus nine doses of PBMT with 25W output power over three weeks, or (3) usual care plus nine doses of PBMT with 10W output power over three weeks. Both 10W and 25W PBMT participants received the same total dose (10J/cm2) by utilizing a simple area equation. Pain (with Defense and Veterans Pain Rating Scale) and function (by Foot and Ankle Ability Measure) were measured at baseline, weeks 3, and 6 for all groups, and at 13 and 26 weeks for PBMT groups. Results: PBMT groups experienced a reduction in pain over the first three weeks (from an average of 4.5 to 2.8) after which their pain levels remained mostly constant, while the UC group experienced a smaller reduction in pain (from an average of 4 to 3.8). The effects on pain were not different between PBMT groups. PBMT in both treatment groups also improved function more than the UC group, again with the improvement occurring within the first three weeks. Conclusions: Pain and function improved during the three weeks of PBMT plus UC and remained stable over the following three weeks. Improvements sustained through six months in the PBMT plus UC groups. Level of Evidence: Level II- RCT or Prospective Comparative Study
31 March 2020 in Veterinary and Comparative Orthopaedics and Traumatology
Objective Rotator cuff tendon tears are the most common soft tissue injuries in the shoulder joint. Various animal models have been described for this condition, but all current translational animal models have inherent weaknesses in their ability to generate chronically degenerated rotator cuff tendons. The objective of this study was to evaluate a partial infraspinatus tendon transection model as a means of creating a chronically degenerated rotator cuff tendon in an ovine model and compare the injury characteristics of this model to those observed in human patients with severe chronic rotator cuff tendon injuries. Study Design The infraspinatus tendons of six sheep were partially detached followed by capping of the detached medial section of the tendon with Gore-Tex. Human tissue samples of the supraspinatus tendon were harvested from patients undergoing primary reverse shoulder arthroplasty and served as positive controls of chronic rotator cuff tendinopathy. Results Transected sheep tendons were characterized predominantly by an acute reactive and reparative pathological process as compared with the chronic degenerative changes observed in the human tendons. In contrast, the non-transected portion of the ovine tendon showed histological changes, which were more chronic and degenerative in nature when compared with the transected tendon. Conclusion Overall, histological features of the non-transected portion of ovine tendon were more similar to those observed in the chronic degenerated human tendon.