Vessela Krasteva

Dr. Vessela Krasteva

Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, Sofia-Grad, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2006 in Medical Engineering & Physics
Verified
Journal Article
Closed access
ICIvaylo Christov
Ivaylo Christov
GGGèrman Gómez-Herrero
Gèrman Gómez-Herrero
Vessela KrastevaVessela Krasteva
Vessela Krasteva
IJIrena Jekova
Irena Jekova
AGAtanas Gotchev
Atanas Gotchev
KEKaren Egiazarian
Karen Egiazarian
The prompt and adequate detection of abnormal cardiac conditions by computer-assisted long-term monitoring systems depends greatly on the reliability of the implemented ECG automatic analysis technique, which has to discriminate between different types of heartbeats. In this paper, we present a comparative study of the heartbeat classification abilities of two techniques for extraction of characteristic heartbeat features from the ECG: (i) QRS pattern recognition method for computation of a large collection of morphological QRS descriptors; (ii) Matching Pursuits algorithm for calculation of expansion coefficients, which represent the time-frequency correlation of the heartbeats with extracted learning basic waveforms. The Kth nearest neighbour classification rule has been applied for assessment of the performances of the two ECG feature sets with the MIT-BIH arrhythmia database for QRS classification in five heartbeat types (normal beats, left and right bundle branch blocks, premature ventricular contractions and paced beats), as well as with five learning datasets-one general learning set (GLS, containing 424 heartbeats) and four local sets (GLS+about 0.5, 3, 6, 12 min from the beginning of the ECG recording). The achieved accuracies by the two methods are sufficiently high and do not show significant differences. Although the GLS was selected to comprise almost all types of appearing heartbeat waveforms in each file, the guaranteed accuracy (sensitivity between 90.7% and 99%, specificity between 95.5% and 99.9%) was reasonably improved when including patient-specific local learning set (sensitivity between 94.8% and 99.9%, specificity between 98.6% and 99.9%), with optimal size found to be about 3 min. The repeating waveforms, like normal beats, blocks, paced beats are better classified by the Matching Pursuits time-frequency descriptors, while the wide variety of bizarre premature ventricular contractions are better recognized by the morphological descriptors.

7 August 2004 in Physiological Measurement
Verified
Journal Article
Closed access
IJIrena Jekova
Irena Jekova
Vessela KrastevaVessela Krasteva
Vessela Krasteva
The automatic external defibrillator (AED) is a lifesaving device, which processes and analyses the electrocardiogram (ECG) and delivers a defibrillation shock to terminate ventricular fibrillation or tachycardia above 180 bpm. The built-in algorithm for ECG analysis has to discriminate between shockable and non-shockable rhythms and its accuracy, represented by sensitivity and specificity, is aimed at approaching the maximum values of 100%. An algorithm for VF/VT detection is proposed using a band-pass digital filter with integer coefficients, which is very simple to implement in real-time operation. A branch for wave detection is activated for heart rate measurement and an auxiliary parameter calculation. The method was tested with ECG records from the widely recognized databases of the American Heart Association (AHA) and the Massachusetts Institute of Technology (MIT). A sensitivity of 95.93% and a specificity of 94.38% were obtained.

1 September 2007 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Vessela KrastevaVessela Krasteva
Vessela Krasteva
IJIrena Jekova
Irena Jekova

15 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IJIrena Jekova
Irena Jekova
Vessela KrastevaVessela Krasteva
Vessela Krasteva
High performance of the shock advisory analysis of the electrocardiogram (ECG) during cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OHCA) is important for better management of the resuscitation protocol. It should provide fewer interruptions of chest compressions (CC) for non-shockable organized rhythms (OR) and Asystole, or prompt CC stopping for early treatment of shockable ventricular fibrillation (VF). Major disturbing factors are strong CC artifacts corrupting raw ECG, which we aimed to analyze with optimized end-to-end convolutional neural network (CNN) without pre-filtering or additional sensors. The hyperparameter random search of 1500 CNN models with 2–7 convolutional layers, 5–50 filters and 5–100 kernel sizes was done on large databases from independent OHCA interventions for training (3001 samples) and validation (2528 samples). The best model, named CNN3-CC-ECG network with three convolutional layers (filters@kernels: 5@5,25@20,50@20) presented Sensitivity Se(VF) = 89%(268/301), Specificity Sp(OR) = 91.7%(1504/1640), Sp(Asystole) = 91.1%(3325/3650) on an independent test OHCA database. CNN3-CC-ECG’s ability to effectively extract features from raw ECG signals during CPR was comprehensively demonstrated, and the dependency on the CPR corruption level in ECG was tested. We denoted a significant drop of Se(VF) = 74.2% and Sp(OR) = 84.6% in very strong CPR artifacts with a signal-to-noise ratio of SNR < −9 dB, p < 0.05. Otherwise, for strong, moderate and weak CC artifacts (SNR > −9 dB, −6 dB, −3 dB), we observed insignificant performance differences: Se(VF) = 92.5–96.3%, Sp(OR) = 93.4–95.5%, Sp(Asystole) = 92.6–94.0%, p > 0.05. Performance stability with respect to CC rate was validated. Generalizable application of the optimized computationally efficient CNN model was justified by an independent OHCA database, which to our knowledge is the largest test dataset with real-life cardiac arrest rhythms during CPR.

19 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Vessela KrastevaVessela Krasteva
Vessela Krasteva
SMSarah Ménétré
Sarah Ménétré
JDJean-Philippe Didon
Jean-Philippe Didon
IJIrena Jekova
Irena Jekova
Deep neural networks (DNN) are state-of-the-art machine learning algorithms that can be learned to self-extract significant features of the electrocardiogram (ECG) and can generally provide high-output diagnostic accuracy if subjected to robust training and optimization on large datasets at high computational cost. So far, limited research and optimization of DNNs in shock advisory systems is found on large ECG arrhythmia databases from out-of-hospital cardiac arrests (OHCA). The objective of this study is to optimize the hyperparameters (HPs) of deep convolutional neural networks (CNN) for detection of shockable (Sh) and nonshockable (NSh) rhythms, and to validate the best HP settings for short and long analysis durations (2–10 s). Large numbers of (Sh + NSh) ECG samples were used for training (720 + 3170) and validation (739 + 5921) from Holters and defibrillators in OHCA. An end-to-end deep CNN architecture was implemented with one-lead raw ECG input layer (5 s, 125 Hz, 2.5 uV/LSB), configurable number of 5 to 23 hidden layers and output layer with diagnostic probability p ∈ [0: Sh,1: NSh]. The hidden layers contain N convolutional blocks × 3 layers (Conv1D (filters = Fi, kernel size = Ki), max-pooling (pool size = 2), dropout (rate = 0.3)), one global max-pooling and one dense layer. Random search optimization of HPs = {N, Fi, Ki}, i = 1, … N in a large grid of N = [1, 2, … 7], Fi = [5;50], Ki = [5;100] was performed. During training, the model with maximal balanced accuracy BAC = (Sensitivity + Specificity)/2 over 400 epochs was stored. The optimization principle is based on finding the common HPs space of a few top-ranked models and prediction of a robust HP setting by their median value. The optimal models for 1–7 CNN layers were trained with different learning rates LR = [10−5; 10−2] and the best model was finally validated on 2–10 s analysis durations. A number of 4216 random search models were trained. The optimal models with more than three convolutional layers did not exhibit substantial differences in performance BAC = (99.31–99.5%). Among them, the best model was found with {N = 5, Fi = {20, 15, 15, 10, 5}, Ki = {10, 10, 10, 10, 10}, 7521 trainable parameters} with maximal validation performance for 5-s analysis (BAC = 99.5%, Se = 99.6%, Sp = 99.4%) and tolerable drop in performance (<2% points) for very short 2-s analysis (BAC = 98.2%, Se = 97.6%, Sp = 98.7%). DNN application in future-generation shock advisory systems can improve the detection performance of Sh and NSh rhythms and can considerably shorten the analysis duration complying with resuscitation guidelines for minimal hands-off pauses.

16 December 2002 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
Vessela KrastevaVessela Krasteva
Vessela Krasteva
SPSava P Papazov
Sava P Papazov
Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.