Alejandra Aguado Del Hoyo

Mrs. Alejandra Aguado Del Hoyo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LCLucilio Cordero-Grande
Lucilio Cordero-Grande
JOJuan Ortuño Ortuño
Juan Ortuño Ortuño
AHAlejandra Aguado Del Hoyo
Alejandra Aguado Del Hoyo
AUAlena Uus
Alena Uus
MDMaria Deprez
Maria Deprez
MLMaría Jesús Ledesma-Carbayo
María Jesús Ledesma-Carbayo
Magnetic resonance imaging of whole fetal body and placenta is limited by different sources of motion affecting the womb. Usual scanning techniques employ single-shot multi-slice sequences where anatomical information in different slices may be subject to different deformations, contrast variations or artifacts. Volumetric reconstruction formulations have been proposed to correct for these factors, but they must accommodate a non-homogeneous and non-isotropic sampling, so regularization becomes necessary. Thus, in this paper we propose a deep generative prior for robust volumetric reconstructions integrated with a diffeomorphic volume to slice registration method. Experiments are performed to validate our contributions and compare with methods in the literature in a cohort of 72 fetal datasets in the range of 20-36 weeks gestational age. Quantitative as well as radiological assessment suggest improved image quality and more accurate prediction of gestational age at scan is obtained when comparing to state of the art reconstruction methods. In addition, gestational age prediction results from our volumetric reconstructions are competitive with existing brain-based approaches, with boosted accuracy when integrating information of organs other than the brain. Namely, a mean absolute error of 0.618 weeks (R 2 = 0.958) is achieved when combining fetal brain and trunk information.

23 January 2022 in European Journal of Pediatrics
Verified
Journal Article
Closed access
PDF file
MAMaría Arriaga-Redondo
María Arriaga-Redondo
DBDorotea Blanco Bravo
Dorotea Blanco Bravo
AHAlejandra Aguado Del Hoyo
Alejandra Aguado Del Hoyo
AAAna Polo Arrondo
Ana Polo Arrondo
YMYolanda Ruiz Martín
Yolanda Ruiz Martín
MSManuel Sanchez-Luna
Manuel Sanchez-Luna

1 September 2016 in European Journal of Paediatric Neurology
Verified
Journal Article
Closed access
LLLAURA BUTRAGUEÑO LAISECA
LAURA BUTRAGUEÑO LAISECA
NONiki Oikonomopoulou
Niki Oikonomopoulou
MHMaría Concepción Miranda Herrero
María Concepción Miranda Herrero
EVEstíbaliz Barredo Valderrama
Estíbaliz Barredo Valderrama
MVMaría Vázquez-López
María Vázquez-López
RMRosa M. Meiriño
Rosa M. Meiriño

25 April 2016 in American Journal of Perinatology Reports
Verified
Journal Article
Open access
PDF file
ESEster Sanz-López
Ester Sanz-López
AHAlejandra Aguado Del Hoyo
Alejandra Aguado Del Hoyo
GMGema Manrique
Gema Manrique
JDJuan Carlos De-Agustín
Juan Carlos De-Agustín
MSManuel Sanchez-Luna
Manuel Sanchez-Luna
RGRebeca Gregorio-Hernández
Rebeca Gregorio-Hernández
Introduction Congenital umbilical arteriovenous malformations (AVMs) are extremely rare. We present the first case of congenital umbilical AVM with feeding arteries originating not only from abdominal but also from the mammary arteries. Case Report A 34-week gestational age newborn was transferred to our hospital with a supraumbilical murmur. Abdominal Doppler ultrasound (US) showed a large vascular AVM, with multiple feeding arteries and several venous drainage structures to the umbilical vein and also a persistent ductus venosus. She developed signs of heart failure on the 12th day of life. Computed tomography angiogram revealed an umbilical congenital AVM with feeding arteries originating from the external iliac, hypogastric, epigastric, and mammary arteries and a dilated umbilical vein draining the cluster. Also, a patent ductus venosus was observed. At 14 days of life, laparotomy was performed but due to the complexity of the feeding arteries of the AVM, complete exeresis was not performed, but only ligation of these arteries was made, to reduce the surgical risk. Conclusion To our knowledge, this is the first time that no complete excision was made but only ligation of the arteries. The infant was discharged home on postoperative day 14 being asymptomatic. Follow-up Doppler US showed thrombosed vascular structures.

24 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DGDaniel Sánchez García
Daniel Sánchez García
AHAlejandra Aguado Del Hoyo
Alejandra Aguado Del Hoyo
MPMaría Sánchez Pérez
María Sánchez Pérez
SLSantiago García-Tizón Larroca
Santiago García-Tizón Larroca
YMYolanda Ruiz Martín
Yolanda Ruiz Martín
Juan Antonio De Leon-LuisJuan Antonio De Leon-Luis
Juan Antonio De Leon-Luis
Objective: To examine the influence of age, sex and height on the symphysis–ischial spine distance (SID) measured on pelvic Computed tomography (CT)images in subjects of reproductive age, and to determine the interobserver reproducibility. This measurement (SID) is of great importance because the use of intrapartum ultrasound is based on the assumption of a specific value (30 mm) of such a measurement. Methods: This was a cross-sectional descriptive study in which SID was measured in subjects aged 20 to 44 years who had been scheduled for pelvic CT at our centre from January 2018 to May 2021 for different reasons. Radiographic measurements of the pelvis were obtained through the multiplanar reconstruction of the CT image. The images obtained from all of the participants were independently assessed by three senior radiologists, and the SID measurements made by each one were blinded from those of the remaining observers. Correlations between the SID and patient age, height and sex were analyzed by univariate and multivariate linear regression. Results: The mean SID for 87 of the enrolled participants (45 women, 42 men) was 28.2 ± 6.25 mm. Among the observers, the mean difference in this distance was 1 to 2 mm, and was scarcely related to measurement size, with agreement being greater than 70%. The mean SID was significantly related to sex and height (SID = −24.9 − 6.51 × sex (0 or 1) + 0.34 × height (cm); p = 0.01; sex equals 1 for a man and 0 for a woman), such that it was a mean of 2.5 mm greater in women than men (29.50 mm vs. 26.99 mm). Conclusion: Measurements of SID on CT images show good interobserver reproducibility, and are related to sex and height.

21 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ALANGEL M LANCHARRO-ZAPATA
ANGEL M LANCHARRO-ZAPATA
AHAlejandra Aguado Del Hoyo
Alejandra Aguado Del Hoyo
MOMaría del Carmen Sánchez Gómez de Orgaz
María del Carmen Sánchez Gómez de Orgaz
Miguel A. OrtegaMiguel A. Ortega
Miguel A. Ortega
Juan Antonio De Leon-LuisJuan Antonio De Leon-Luis
Juan Antonio De Leon-Luis
Background/Objectives: Liver elastography is increasingly used in neonatal intensive care units (NICUs) as a non-invasive, radiation-free, reproducible technique for assessing liver stiffness. This technique demonstrates substantial advantages over conventional ultrasound in diagnosing diffuse liver diseases by providing quantitative measures of tissue elasticity. This article aims to describe the most critical milestones for performing liver elastography ultrasound point-of-care, a tool increasingly used to complement traditional ultrasound in the study of the liver in intensive care units where the population is very susceptible to manipulation. Methods: Techniques such as point-shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) have become key in evaluating conditions such as hypoxic-ischemic liver disease, cholestatic diseases, storage and metabolic disorders, or infectious liver conditions. However, despite its usefulness, performing elastography in neonates, particularly in those weighing less than 1000 g or in high-frequency oscillatory ventilation, presents notable challenges, including the extreme sensitivity of neonates to touch, noise, and temperature changes and the difficulty in obtaining accurate measurements due to limited hepatic depth. Results: Key factors for the success of sonoelastography in this population include minimizing contact time, adjusting mechanical and thermal indices to meet biosecurity guidelines, and ensuring patient comfort and stability during the procedure. Despite these challenges, elastography has proven helpful in routine clinical practice. Conclusions: The growing evidence on elastography has provided standardized reference values, further enhancing its clinical applicability in NICU settings.