Brad Kemp

Dr. Brad Kemp

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2018 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
MBMark R. Battle
Mark R. Battle
LPLovena Chedumbarum Pillay
Lovena Chedumbarum Pillay
VLVal J Lowe
Val J Lowe
DKDavid Knopman
David Knopman
BKBrad Kemp
Brad Kemp
CBChristopher J. Buckley
Christopher J. Buckley
A standardised method for quantifying β-amyloid PET tracers would allow comparison across different tracers and different sites. The development of the Centiloid scale has aimed to achieve this, applying a common scale to better aid the diagnosis and prognosis of Alzheimer’s disease (AD) and to monitor anti-amyloid therapeutic interventions. Here, we apply the Centiloid method to [18F]flutemetamol and [11C]PiB (PiB, Pittsburgh compound B) PET images and derive the scaling factor to express their binding in Centiloids. Paired PiB and [18F]flutemetamol scans for 74 subjects, including 24 young healthy controls (37 ± 5 years), were analysed using the standard Centiloid method. The same subjects were also analysed using PMOD- and FSL-based pipelines as well as SPM8. Test-retest analysis of 10 AD subjects was also performed with each pipeline. The standard uptake value ratios (SUVR), determined using the standard SPM8 Centiloid process, showed a strong correlation between [18F]flutemetamol (Flute) and PiB binding (SUVR-Flute = 0.77 × SUVR-PiB + 0.22, R2 = 0.96). Application of the standard Centiloid process allowed the calculation of a direct conversion equation for SUVR-Flute to Centiloid units (CL) (CL = (121.42*SUVR-Flute) − 121.16). Analysis of the data via the two alternate Centiloid pipelines allowed us to derive standardised, SPM8-equivalent equations for both PMOD (CL = (115.24*SUVR-Flute) − 107.86) and FSL (CL = (120.32*SUVR-Flute) − 112.75) respectively. Test-retest analysis of 10 AD subjects showed an approximate 2% difference for each pipeline. [18F]flutemetamol data can now be expressed in Centiloid units, enhancing its utility in clinical and research applications for β-amyloid imaging. The standard Centiloid method also demonstrates that [18F]flutemetamol has favourable performance compared with PiB and other β-amyloid tracers. Test-retest difference averaged 2%, with no difference between image processing pipelines. Centiloid scaling is robust and can be implemented on a number of platforms.

25 March 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BKBrad Kemp
Brad Kemp
CHCarrie B Hruska
Carrie B Hruska
AMAaron R McFarland
Aaron R McFarland
MLMark W Lenox
Mark W Lenox
VLVal J Lowe
Val J Lowe
National Electrical Manufacturers Association (NEMA) NU 2-2007 performance measurements were conducted on the Inveon preclinical small animal PET system developed by Siemens Medical Solutions. The scanner uses 1.51 x 1.51 x 10 mm LSO crystals grouped in 20 x 20 blocks; a tapered light guide couples the LSO crystals of a block to a position-sensitive photomultiplier tube. There are 80 rings with 320 crystals per ring and the ring diameter is 161 mm. The transaxial and axial fields of view (FOVs) are 100 and 127 mm, respectively. The scanner can be docked to a CT scanner; the performance characteristics of the CT component are not included herein. Performance measurements of spatial resolution, sensitivity, scatter fraction and count rate performance were obtained for different energy windows and coincidence timing window widths. For brevity, the results described here are for an energy window of 350-650 keV and a coincidence timing window of 3.43 ns. The spatial resolution at the center of the transaxial and axial FOVs was 1.56, 1.62 and 2.12 mm in the tangential, radial and axial directions, respectively, and the system sensitivity was 36.2 cps kBq(-1) for a line source (7.2% for a point source). For mouse- and rat-sized phantoms, the scatter fraction was 5.7% and 14.6%, respectively. The peak noise equivalent count rate with a noisy randoms estimate was 1475 kcps at 130 MBq for the mouse-sized phantom and 583 kcps at 74 MBq for the rat-sized phantom. The performance measurements indicate that the Inveon PET scanner is a high-resolution tomograph with excellent sensitivity that is capable of imaging at a high count rate.

27 October 2017 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
HJHuailei Jiang
Huailei Jiang
NSNicholas R. Schmit
Nicholas R. Schmit
AKAlex R. Koenen
Alex R. Koenen
ABAditya Bansal
Aditya Bansal
Mukesh PandeyMukesh Pandey
Mukesh Pandey
TDTimothy R. DeGrado
Timothy R. DeGrado
18F-Tetrafluoroborate (18F-TFB) is a promising iodide analog for PET imaging of thyroid cancer and sodium/iodide symporter (NIS) reporter activity in viral therapy applications. The aim of this study was to evaluate the safety, pharmacokinetics, biodistribution, and radiation dosimetry of high-specific activity 18F-TFB in healthy human subjects. 18F-TFB was synthesized with specific activity of 3.2 ± 1.3 GBq/μmol (at the end of synthesis). Dynamic and whole-body static PET/CT scans over 4 h were performed after intravenous administration of 18F-TFB (333–407 MBq) in four female and four male healthy volunteers (35 ± 11 years old). Samples of venous blood and urine were collected over the imaging period and analyzed by ion-chromatography HPLC to determine tracer stability. Vital signs and clinical laboratory safety assays were measured to evaluate safety. 18F-TFB administration was well tolerated with no significant findings on vital signs and no clinically meaningful changes in clinical laboratory assays. Left-ventricular blood pool time-activity curves showed a multi-phasic blood clearance of 18F-radioactivity with the two rapid clearance phases over the first 20 min, followed by a slower clearance phase. HPLC analysis showed insignificant 18F-labeled metabolites in the blood and urine over the length of the study (4 h). High uptakes were seen in the thyroid, stomach, salivary glands, and bladder. Urinary clearance of 18F-TFB was prominent. Metabolic stability was evidenced by low accumulation of 18F-radioactivity in the bone. Effective doses were 0.036 mSv/MBq in males and 0.064 mSv/MBq in females (p = 0.08, not significant). This initial study in healthy human subjects showed 18F-TFB was safe and distributed in the human body similar to other iodide analogs. These data support further translational studies with 18F-TFB as NIS gene reporter and imaging biomarker for thyroid cancer and other disease processes that import iodide.

1 December 2006
Verified
Journal Article
Closed access
BKBrad Kemp
Brad Kemp
CKChang Kim
Chang Kim
JWJohn J Williams
John J Williams
AGAlexander Ganin
Alexander Ganin
VLVal J Lowe
Val J Lowe
N(National Electrical Manufacturers Association (NEMA)
National Electrical Manufacturers Association (NEMA)

26 September 2019 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
VLV.T. Lehman
V.T. Lehman
FDF.E. Diehn
F.E. Diehn
SBS.M. Broski
S.M. Broski
MNM.A. Nathan
M.A. Nathan
BKBrad Kemp
Brad Kemp
TMT.P. Maus
T.P. Maus
BACKGROUND AND PURPOSE: Prior retrospective studies have suggested that both T2 hyperintensity and gadolinium enhancement on fat-suppressed MR imaging are associated with lumbar facet joint pain, but prospective evaluation of FDG-PET/MR imaging with a standardized protocol and correlation to clinical findings are lacking. The primary aim was to prospectively assess a standardized FDG-PET/MRI protocol in patients with suspected facetogenic low back pain, with determination of the concordance of imaging and clinical findings. MATERIALS AND METHODS: Ten patients with clinically suspected facetogenic low back pain were prospectively recruited with a designation of specific facet joints implicated clinically. Subsequently, patients underwent an FDG-PET/MR imaging examination with gadolinium. Each facet joint was graded for perifacet signal change on MR imaging and FDG activity. The frequency and correlation of MR imaging, FDG-PET, and clinical findings were determined. RESULTS: FDG activity showed high concordance with high overall MR imaging scores (concordance correlation coefficient = 0.79). There was concordance of the clinical side of pain with the side of high overall MR imaging scores and increased FDG activity on 12/20 (60%) sides. Both a high overall MR imaging score (concordance correlation coefficient = 0.12) and FDG-PET findings positive for increased activity (concordance correlation coefficient = 0.10) had low concordance with the specific clinically implicated facet joints. Increased FDG activity or high MR imaging scores or both were present in only 10/29 (34%) facet joints that had been clinically selected for percutaneous intervention. Eleven (11%) facet joints that had not been selected for treatment demonstrated these imaging findings. CONCLUSIONS: There was low concordance of perifacet signal change and FDG activity with clinically implicated facet joints. This could indicate either the potential to change patient management or a lack of biomarker accuracy. Therefore, additional larger randomized studies with the use of comparative medial branch blocks would be useful to further investigate the clinical utility of these findings.

9 June 2025 in Journal of Nuclear Cardiology
Verified
Journal Article
Open access
DKDan J. Kadrmas
Dan J. Kadrmas
BKBrad Kemp
Brad Kemp
ASArkadiusz Sitek
Arkadiusz Sitek
PCPanithaya Chareonthaitawee
Panithaya Chareonthaitawee
18F-flurpiridaz is the newest positron emission tomography myocardial perfusion tracer approved in the US for evaluating myocardial ischemia and infarction (Flyrcado™, GE HealthCare). The 110 minute half-life of 18F enables flurpiridaz to be made and shipped regionally; however, it also results in high levels of residual tracer activity for same-day rest/stress scanning. This study provides a technical evaluation of immediate back-to-back rest/stress flurpiridaz PET with no delay, using a commercially-available software medical device (mfiVerse™, MultiFunctional Imaging LLC) to correct for residual activity effects. Retrospectively-obtained separate-scan dynamic rest and pharmacologic stress flurpiridaz images in 11 subjects were digitally shifted and combined to model a 15 minute rest/stress procedure with rest scan from 0-8 min. and stress scan from 8-15 min., providing a paired-sample study design. Modeling of residual tracer effects included both distributed activity and stress effects upon residual arterial input. Residual activity biased mean stress pixel values and myocardial blood flow (MBF) by +31% and +64%, respectively, as compared to the reference stress images without residual activity. These biases were each reduced to less than 1% after residual activity correction. Linear regression analysis found that corrected stress pixel values (r=0.998) and MBF (r=0.994) closely matched reference stress values, both being equivalent to separate-scan values to less than half of test-retest variability (p<0.001). Summed Stress Scores averaged 2.5 points lower for uncorrected images vs. the reference images, and averaged 0.4 points lower after correction. Within the study limitations, these results demonstrate that rest and stress flurpiridaz PET images can be obtained immediately back-to-back without rest-stress delay when accurate correction for residual activity is performed.