Karapet Davtyan

Karapet Davtyan

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in EP Europace
Verified
Journal Article
Open access
PDF file
KKKarl-Heinz Kuck
Karl-Heinz Kuck
DLDlebedev Lebedev
Dlebedev Lebedev
EMEvgeny N Mikhaylov
Evgeny N Mikhaylov
ARAlexander Romanov
Alexander Romanov
LGLászló Gellér
László Gellér
FOFeifan Ouyang
Feifan Ouyang
Delay of progression from paroxysmal to persistent atrial fibrillation (AF) is an important measure of long-term success of AF treatment. However, published data on the impact of catheter ablation on AF progression are limited. This study evaluates whether radiofrequency (RF) catheter ablation delays the progression of AF compared with antiarrhythmic drug (AAD) treatment using current AF management guidelines. This prospective, randomized, controlled, two-arm, open-label trial was conducted at 29 hospitals and medical centres across 13 countries. Patients were randomized 1 : 1 to RF ablation or AAD treatment. The primary endpoint was the rate of persistent AF/atrial tachycardia (AT) at 3 years. After early study termination following slow enrolment, 255 (79%) of the planned 322 patients were enrolled (RF ablation, n = 128, AAD, n = 127); 36% of patients in the RF ablation group and 41% in the AAD group completed 3 years of follow-up. For the primary endpoint, the Kaplan–Meier estimate of the rate of persistent AF/AT at 3 years was significantly lower with RF ablation [2.4% (95% confidence interval (CI), 0.6–9.4%)] than with AAD therapy [17.5% (95% CI, 10.7–27.9%); one-sided P = 0.0009]. Patients ≥65 years were ∼4 times more likely to progress to persistent AF/AT than patients <65 years, suggesting RF ablation can delay disease progression [hazard ratio: 3.87 (95% CI, 0.88–17.00); P = 0.0727]. Primary adverse events were reported for eight patients in the RF ablation group. Radiofrequency ablation is superior to guideline-directed AAD therapy in delaying the progression from paroxysmal to persistent AF.

12 March 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
KDKarapet Davtyan
Karapet Davtyan
VSVictoria Shatakhtsyan
Victoria Shatakhtsyan
HPHermine Poghosyan
Hermine Poghosyan
ADAlexandr Deev
Alexandr Deev
ATAlexey Tarasov
Alexey Tarasov
SBSergey Boytcov
Sergey Boytcov
Introduction. While several studies have compared the radiofrequency current (RFC) and cryoablation for the treatment of patients with atrial fibrillation (AF), no study has monitored the long-term outcomes with the usage of implantable loop recorders (ILRs). Methods. We enrolled 89 consecutive patients with nonvalvular paroxysmal AF (N=44 for RFC and N=45 for cryoballoon). The primary efficacy end point was the assessment of effectiveness for each group (RFC versus cryoballoon) when examining freedom from arrhythmia by monitoring with ECG, Holter, and implantable loop recoder (ILR). The primary safety end point compared rates of adverse events between both groups. The secondary efficacy end point examined the duration of the postablation blanking period from ILR retrieved data. Results. The mean age of the study population was 56.6±10.2 years, and the follow-up duration was 12 months. There were no differences in baseline patient characteristics between groups. At 12 months, the absolute effectiveness (measured by ILR) was 65.9% in the RFC group and 51.1% in the cryoballoon group (OR = 1.85; 95% CI: 0.79–4.35; p=0.157), and the clinical effectiveness (measured by ECG and Holter) was 81.8% in the RFC group and 55.6% in the cryoballoon group (OR = 3.6; 95% CI: 1.37–9.46; p=0.008). There was no difference in safety between both groups. Asymptomatic episodes were significantly more present in the RFC group as measured by ILRs (p<0.010). In cryoballoon group, arrhythmia episodes were recorded equally irrespective of the follow-up method (i.e., ECG and Holter versus ILR (p>0.010)). The blanking period does not seem to be as important in cryoballoon as compared to RFC. Conclusion. RFC and cryoballoon ablation had similar absolute effectiveness at 12 months. ECG and Holter were effective when assessing the efficacy of the cryoballoon ablation; however, in the RFC group, ILR was necessary to accurately assess long-term efficacy.

29 August 2022 in Digital Health
Verified
Journal Article
Open access
EBErica Barbazza
Erica Barbazza
DIDamir Ivanković
Damir Ivanković
KDKarapet Davtyan
Karapet Davtyan
MPMircha Poldrugovac
Mircha Poldrugovac
ZYZhamin Yelgezekova
Zhamin Yelgezekova
DKDionne Kringos
Dionne Kringos
Background: Governments across the World Health Organization (WHO) European Region have prioritised dashboards for reporting COVID-19 data. The ubiquitous use of dashboards for public reporting is a novel phenomenon. Objective: This study explores the development of COVID-19 dashboards during the first year of the pandemic and identifies common barriers, enablers and lessons from the experiences of teams responsible for their development. Methods: We applied multiple methods to identify and recruit COVID-19 dashboard teams, using a purposive, quota sampling approach. Semi-structured group interviews were conducted from April to June 2021. Using elaborative coding and thematic analysis, we derived descriptive and explanatory themes from the interview data. A validation workshop was held with study participants in June 2021. Results: Eighty informants participated, representing 33 national COVID-19 dashboard teams across the WHO European Region. Most dashboards were launched swiftly during the first months of the pandemic, February to May 2020. The urgency, intense workload, limited human resources, data and privacy constraints and public scrutiny were common challenges in the initial development stage. Themes related to barriers or enablers were identified, pertaining to the pre-pandemic context, pandemic itself, people and processes and software, data and users. Lessons emerged around the themes of simplicity, trust, partnership, software and data and change. Conclusions: COVID-19 dashboards were developed in a learning-by-doing approach. The experiences of teams reveal that initial underpreparedness was offset by high-level political endorsement, the professionalism of teams, accelerated data improvements and immediate support with commercial software solutions. To leverage the full potential of dashboards for health data reporting, investments are needed at the team, national and pan-European levels.

7 October 2021 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
KDKarapet Davtyan
Karapet Davtyan
ATArpi H. Topchyan
Arpi H. Topchyan
HBHakob A. Brutyan
Hakob A. Brutyan
EKElena N. Kalemberg
Elena N. Kalemberg
MKMaria Kharlap
Maria Kharlap
MKMaria V. Kuznetsova
Maria V. Kuznetsova
Background: Early recurrences of atrial arrhythmias (ERAA) after atrial fibrillation (AF) catheter ablation do not predict procedural failure. A well-demarcated homogeneous lesion delivered by cryoballoon is less arrhythmogenic, and the recommended three-months blanking period may not refer to cryoballoon ablation (CBA). Objective: We aimed to evaluate the predictive role of ERAA after second-generation CBA using an implantable loop recorder. Methods: This prospective observational study enrolled 100 patients (58 males, median age 58) with paroxysmal/persistent AF undergoing pulmonary vein (PV) CBA using second-generation cryoballoon with simultaneous ECG loop recorder implantation. The duration of follow-up was 12 months, with scheduled visits at 3, 6 and 12 months. Results: 99 patients from 100 completed the 12-month follow-up period. ERAA occurred in 31.3 % of patients. 83.9 % of patients with ERAA also developed late recurrences. The 12-month freedom from AF in patients with ERAA was significantly lower than in those without ERAA (p < 0.0001). Non-paroxysmal AF and longer arrhythmia history were associated with increased risk of both early (HR 3.27; 95 % CI 1.32–8.08; p = 0.010 and HR 1.0147; 95 % CI 1.008–1.086; p = 0.015, respectively) and late recurrences (HR 3.89; 95 % CI 1.67–9.04; p = 0.002 and HR 1.0142; 95 % CI 1.007–1.078; p = 0.019, respectively) of AF. ERAA were another predictor for procedural failure (HR 15.2; 95 % CI (6.42–35.99; p = 0.019). Conclusions: ERAA occurred in the third of the patients after PV second-generation CBA and are strongly associated with procedural failure. Longer duration of AF history and persistent AF are independent predictors of AF’s early and late recurrence.

18 August 2019 in Russian Journal of Cardiology
Verified
Journal Article
Open access
KDKarapet Davtyan
Karapet Davtyan
AKA. A. Kalemberg
A. A. Kalemberg
ETE. N. Tsareva
E. N. Tsareva
OBOlga VLADIMIROVNA Blagova
Olga VLADIMIROVNA Blagova
MHM. S. Harlap
M. S. Harlap

9 August 2022 in Russian Journal of Cardiology
Verified
Journal Article
Open access
PDF file
MBMarina G. Bubnova
Marina G. Bubnova
DAD. M. Aronov
D. M. Aronov
MMM. M. Makhinova
M. M. Makhinova
KDKarapet Davtyan
Karapet Davtyan
Aim. To study the clinical efficacy and safety of a personalized exercise program in the rehabilitation of patients with paroxysmal atrial fibrillation (AF) after primary pulmonary vein radiofrequency ablation (RFA).Material and methods. Patients (n=48) with paroxysmal AF who underwent RFA were randomized into two groups: main (n=24) — patients involved in the exercise program and received standard therapy; control (n=24) — patients received standard therapy. The program included exercise complexes with the calculation of energy consumption, step training and walking. The program lasted 6 months, while the follow-up period — 12 months. All patients in the study underwent a faceto-face learning interview.Results. After 6-month exercise program, bicycle ergometer test revealed an increase in duration (by 18,6%, p<0,001) and power (by 24,8%, p<0,01) of the load, while these changes were not revealed in the control group. The positive aftereffect of training on these parameters persisted even after the completion of program. Left atrial and left ventricular end-diastolic dimension remained stable in exercise program group and significantly increased in the control group. In contrast to the control group, the following parameters significantly decreased in trained patients after 6 months: body mass index by 2,8% (p<0,05), systolic blood pressure by 2,1% (p<0,05), heart rate by 12,1% (p<0,05), low-density lipoprotein cholesterol concentration by 18,8% (p<0,001), high-sensitivity C-reactive protein by 22,9% (p<0,05), N-terminal pro-brain natriuretic peptide by 28,2% ( p<0,05), aldosterone by 41,5% (p<0,001) and angiotensin II by 41,3%, p<0,05). In addition, in the exercise program group an increase in high-density lipoprotein cholesterol by 20,6% (p<0,05) and physical activity level by 23,8% (p=0,001) was revealed. At the same time, both groups showed a significant decrease in the concentration of fibrinogen and transforming growth factor-β1. After 6 months, in the exercise program group versus the control group, there was a decrease in the number of registered supraventricular premature beats (p<0,01), episodes of supraventricular tachyarrhythmia (p<0,05), including AF (p<0,05).Conclusion. Involvement of patients with AF after catheter RFA in a cardiac rehabilitation program based on moderate-intensity aerobic training improves exercise tolerance, cardiac function, corrects thrombogenic factors, and reduces the likelihood of arrhythmia recurrence, including AF.