Zhang Guangyi

Mr. Zhang Guangyi


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ZGZhang Guangyi
Zhang Guangyi
LLLinxue LI
Linxue LI
YYYang Yu
Yang Yu
JLJinhao Liu
Jinhao Liu
QZQi Zhang
Qi Zhang
Under the influence of climate change, extreme heat events are becoming more frequent and intense. Understanding the response mechanisms of public building spaces, such as atriums, during extreme heat events is of great significance for developing effective design strategies to enhance the thermal resilience of buildings. This study investigated the effect of atrium spaces on the thermal resilience of buildings during heatwaves, focusing on their ability to mitigate high temperatures under two states: closed and open. The research monitored the indoor and outdoor temperature and humidity data of the atrium of a university building in Shanghai during a typical heatwave, and used statistical methods to analyze the relationships between the thermal resilience indicators and various environmental parameters, including the indoor and outdoor temperatures and ventilation states, to evaluate the thermal performance of the atrium. The results indicate that the atrium demonstrated robust thermal resilience under both closed and open conditions. In the closed phase, the indoor temperature was, on average, approximately 7 °C lower than the outdoor temperature, with the maximum difference reaching 11 °C, and the peak temperature delay was up to 4 h. In the open phase, despite exhibiting larger thermal fluctuations and an increase in temperature non-uniformity, the thermal resilience index improved significantly, from 0.231 in the closed phase to 0.047. The analytical framework developed in this study shows great potential for understanding the thermal resilience mechanisms of buildings during extreme heat events. Additionally, the data-driven insights are invaluable for informing the design strategies of public building spaces, especially in regions prone to extreme heat.

29 August 2026 in Buildings
Verified
Journal Article
Open access
PDF file
LLLinxue LI
Linxue LI
JLJinhao Liu
Jinhao Liu
QZQi Zhang
Qi Zhang
ZGZhang Guangyi
Zhang Guangyi
STSimin TAO
Simin TAO
Traditional skywell dwellings embody climate-responsive passive design but may remain hot and humid under low-wind summer conditions, requiring passive-ventilation retrofits while preserving their spatial organization. Skywell performance and component-level solar chimneys are comparatively well studied, but their direct integration in traditional multi-room dwellings remains at an early stage. This study develops a climate-adaptive retrofit design approach that integrates a solar chimney with the existing skywell of a traditional rammed-earth dwelling in Songyang, China. Field monitoring showed that mean relative humidity exceeded 90% at all five indoor locations. An EnergyPlus Airflow Network model was calibrated against hourly temperatures from four rooms, yielding RMSE values of 0.33–0.91 °C, with 84.8% of predictions within ±1 °C. The calibrated model was used to compare the baseline and retrofit configurations during a selected 72 h hot period and across the full summer, while the 2000-configuration parametric study retained the 72 h window. During the selected period, the retrofit lowered the simulated operative temperature in all 432 paired hourly comparisons, with a mean reduction of 1.73 °C. Across the full summer, it produced lower operative temperature in 94.7% of 13,248 paired hourly comparisons, with a comparable mean reduction of 1.67 °C, and increased the percentage of hours within the adaptive comfort band from 33.9% to 52.0%. The first-floor hall showed the largest cooling benefit, whereas the second-floor rooms were more responsive to changes in vertical chimney geometry. Overall chimney height and outlet opening height jointly accounted for 85.19–95.09% of random forest feature importance. The collector glazing parameters were more influential in the skywell–chimney zone. These findings support a design hierarchy that prioritizes airflow continuity and vertical exhaust geometry before collector glazing, providing a quantitative basis for solar chimney retrofits that preserve spatial organization of traditional skywell dwellings.

7 September 2026 in Buildings
Verified
Journal Article
Open access
PDF file
QZQi Zhang
Qi Zhang
ZGZhang Guangyi
Zhang Guangyi
LLLinxue LI
Linxue LI
Consecutive warm nights during heatwaves erode the cooling potential of night ventilation (NV), making its effectiveness strongly dependent on both the event and the building conditions. This study quantified the nonlinear effects of heatwave morphology, building thermal mass (TM), and NV strategies on multidimensional thermal responses and identified the operating conditions associated with ventilation performance. Using a 1991–2020 climatological baseline, 36 heatwaves were characterized by eight morphology indicators. A total of 18,000 EnergyPlus simulations examined combinations of three TM levels, two ventilation configurations, window-to-wall ratios (WWRs) ranging from 0.10 to 0.70, openable fraction, and opening schedules. Six indicators captured daytime peaks, persistent overheating, peak temperature lag, nighttime overheating, thermal recovery, and nighttime cooling rate (NCR). Machine learning models were used to identify the governing mechanisms and delineate ventilation strategy regimes. All models achieved R2 values above 0.96 under case-level testing, while event-level performance varied across responses. Increasing TM lowered the median daytime peak temperature by 4.5 °C under cross-ventilation but did not improve every response. Predicted daytime peak risk increased sharply when the mean daily minimum temperature exceeded about 27.0 °C. Ventilation configuration also reversed the effects of opening time, duration, and WWR, precluding a single optimum that is independent of heatwave and building conditions. Effective cooling, operationally defined as positive predicted NCR, was generally associated with earlier opening and longer ventilation. Under single-sided ventilation, achieving stable positive predicted NCR generally required ventilation durations longer than approximately 4 h for buildings with low TM and longer than 6 h for those with medium TM. Under cross-ventilation, the corresponding effective domain in the strategy space contracted markedly, and no stable region with positive predicted NCR emerged for buildings with high TM. These findings support a shift from fixed window opening rules to control strategies tailored to heatwave characteristics and building thermophysical properties. The framework provides a basis for natural ventilation operation informed by forecasts, passive cooling retrofits, and thermally resilient building design.