Seonghun Park

Dr. Seonghun Park

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2004 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
SPSeonghun Park
Seonghun Park
CHC.T Hung
C.T Hung
GAG.A Ateshian
G.A Ateshian

1 December 2003 in Journal of Biomechanics
Verified
Journal Article
Closed access
SPSeonghun Park
Seonghun Park
RKRamaswamy Krishnan
Ramaswamy Krishnan
SNSteven B. Nicoll
Steven B. Nicoll
GAGerard A. Ateshian
Gerard A. Ateshian

1 November 2004 in Journal of Biomechanics
Verified
Journal Article
Closed access
SPSeonghun Park
Seonghun Park
KCKevin D. Costa
Kevin D. Costa
GAGerard A. Ateshian
Gerard A. Ateshian

1 October 2003 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
RKRamaswamy Krishnan
Ramaswamy Krishnan
SPSeonghun Park
Seonghun Park
FEFelix Eckstein
Felix Eckstein
GAGerard A. Ateshian
Gerard A. Ateshian
It has been well established that articular cartilage is compositionally and mechanically inhomogeneous through its depth. To what extent this structural inhomogeneity is a prerequisite for appropriate cartilage function and integrity is not well understood. The first hypothesis to be tested in this study was that the depth-dependent inhomogeneity of the cartilage acts to maximize the interstitial fluid load support at the articular surface, to provide efficient frictional and wear properties. The second hypothesis was that the inhomogeneity produces a more homogeneous state of elastic stress in the matrix than would be achieved with uniform properties. We have, for the first time, simultaneously determined depth-dependent tensile and compressive properties of human patellofemoral cartilage from unconfined compression stress relaxation tests. The results show that the tensile modulus increases significantly from 4.1±1.9MPa in the deep zone to 8.3±3.7MPa at the superficial zone, while the compressive modulus decreases from 0.73±0.26MPa to 0.28±0.16MPa. The experimental measurements were then implemented with the finite-element method to compute the response of an inhomogeneous and homogeneous cartilage layer to loading. The finite-element models demonstrate that structural inhomogeneity acts to increase the interstitial fluid load support at the articular surface. However, the state of stress, strain, or strain energy density in the solid matrix remained inhomogeneous through the depth of the articular layer, whether or not inhomogeneous material properties were employed. We suggest that increased fluid load support at the articular surface enhances the frictional and wear properties of articular cartilage, but that the tissue is not functionally adapted to produce homogeneous stress, strain, or strain energy density distributions. Interstitial fluid pressurization, but not a homogeneous elastic stress distribution, appears thus to be a prerequisite for the functional and morphological integrity of the cartilage.

1 January 2010 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
PTP.A. Torzilli
P.A. Torzilli
MBM. Bhargava
M. Bhargava
SPSeonghun Park
Seonghun Park
CCC.T.C. Chen
C.T.C. Chen

1 June 2012 in Biomaterials
Verified
Journal Article
Closed access
SLSang-Soo Lee
Sang-Soo Lee
ASAshish R. Sharma
Ashish R. Sharma
BCByung-Soo Choi
Byung-Soo Choi
JJJun-Sub Jung
Jun-Sub Jung
JCJun-Dong Chang
Jun-Dong Chang
JNJu-Suk Nam
Ju-Suk Nam