Claire Conway

Claire Conway

Auto-generated profile, based on publicly available information

Claire Conway


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Journal of Anatomy
Verified
Journal Article
Open access
GMGrainne Malone
Grainne Malone
GAGerges Abdelsayed
Gerges Abdelsayed
FBFianait Bligh
Fianait Bligh
FQFatma Al Qattan
Fatma Al Qattan
SSSaifullah Syed
Saifullah Syed
AHAamir Hameed
Aamir Hameed
Mechanical circulatory support (MCS) devices, such as left ventricular assist devices (LVADs) are very useful in improving outcomes in patients with advanced‐stage heart failure. Despite recent advances in LVAD development, pump thrombosis is one of the most severe adverse events caused by LVADs. The contact of blood with artificial materials of LVAD pumps and cannulas triggers the coagulation cascade. Heat spots, for example, produced by mechanical bearings are often subjected to thrombus build‐up when low‐flow situations impair washout and thus the necessary cooling does not happen. The formation of thrombus in an LVAD may compromise its function, causing a drop in flow and pumping power leading to failure of the LVAD, if left unattended. If a clot becomes dislodged and circulates in the bloodstream, it may disturb the flow or occlude the blood vessels in vital organs and cause internal damage that could be fatal, for example, ischemic stroke. That is why patients with LVADs are on anti‐coagulant medication. However, the anti‐coagulants can cause a set of issues for the patient—an example of gastrointestinal (GI) bleeding is given in illustration. On account of this, these devices are only used as a last resort in clinical practice. It is, therefore, necessary to develop devices with better mechanics of blood flow, performance and hemocompatibility. This paper discusses the development of LVADs through landmark clinical trials in detail and describes the evolution of device design to reduce the risk of pump thrombosis and achieve better hemocompatibility. Whilst driveline infection, right heart failure and arrhythmias have been recognised as LVAD‐related complications, this paper focuses on complications related to pump thrombosis, especially blood coagulopathy in detail and potential strategies to mitigate this complication. Furthermore, it also discusses the LVAD implantation techniques and their anatomical challenges.

11 September 2014 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
CCC. Conway
C. Conway
JMJ. P. McGarry
J. P. McGarry
PMP. E. McHugh
P. E. McHugh

14 October 2015 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
KEKay D. Everett
Kay D. Everett
CCClaire Conway
Claire Conway
GDGerard J. Desany
Gerard J. Desany
BBBrian L. Baker
Brian L. Baker
GCGilwoo Choi
Gilwoo Choi
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration’s (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006–2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.

3 March 2021 in Acta Cardiologica
Verified
Journal Article
Open access
PKPatrick Kennelly
Patrick Kennelly
RSRajju Sapkota
Rajju Sapkota
MAMaimoona Azhar
Maimoona Azhar
FCFaisal Habib Cheema
Faisal Habib Cheema
CCClaire Conway
Claire Conway
AHAamir Hameed
Aamir Hameed
In heart failure, fluid overload is a major pathological mechanism leading to vascular congestion, pulmonary congestion and elevated jugular venous pressures. Diuretics play a significant role in the management of patients with congestive heart failure. It is used to relieve the congestive symptoms of heart failure. However, the appropriate use of diuretics remains challenging due to various complications like electrolyte abnormalities, worsening renal function and diuretic resistance. This has prompted towards the search of safer and effective alternatives. This review evaluates the use of diuretics in congestive heart failure and discusses the complications of different types of diuretics, which is essential for successful management of congestion in patients with heart failure and hence to optimise the outcome for the patients.

9 May 2017 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
CCC. Conway
C. Conway
JMJ. P. McGarry
J. P. McGarry
Elazer R. EdelmanElazer R. Edelman
Elazer R. Edelman
PMP. E. McHugh
P. E. McHugh
It is acceptable clinical practice to predilate a severely occluded vessel to allow better positioning of endovascular stents, and while the impact of this intervention has been examined for aggregate response in animals there has been no means to examine whether there are specific vessels that might benefit. Finite element methods offer the singular ability to explore the mechanical response of arteries with specific pathologic alterations in mechanics to stenting and predilation. We examined varying representations of atherosclerotic tissue including homogeneous and heterogeneous dispersion of calcified particles, and elastic, pseudo-elastic, and elastic–plastic constitutive representations of bulk atherosclerotic tissue. The constitutive representations of the bulk atherosclerotic tissue were derived from experimental test data and highlight the importance of accounting for testing mode of loading. The impact of arterial predilation is presented and, in particular, its effect on intimal predicted damage, atherosclerotic tissue von Mises and maximum principal stresses, and luminal deformation was dependent on the type of constitutive representation of diseased tissue, particularly in the presence of calcifications.

15 October 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
CCClaire Conway
Claire Conway
FNFarhad R. Nezami
Farhad R. Nezami
CRCampbell Rogers
Campbell Rogers
AGAdam Groothuis
Adam Groothuis
JSJames C. Squire
James C. Squire
EEElazer R. Edelman
Elazer R. Edelman
Recent concern for local drug delivery and withdrawal of the first Food and Drug Administration-approved bioresorbable scaffold emphasizes the need to optimize the relationships between stent design and drug release with imposed arterial injury and observed pharmacodynamics. In this study, we examine the hypothesis that vascular injury is predictable from stent design and that the expanding force of stent deployment results in increased circumferential stress in the arterial tissue, which may explain acute injury poststent deployment. Using both numerical simulations and ex vivo experiments on three different stent designs (slotted tube, corrugated ring, and delta wing), arterial injury due to device deployment was examined. Furthermore, using numerical simulations, the consequence of changing stent strut radial thickness on arterial wall shear stress and arterial circumferential stress distributions was examined. Regions with predicted arterial circumferential stress exceeding a threshold of 49.5 kPa compared favorably with observed ex vivo endothelial denudation for the three considered stent designs. In addition, increasing strut thickness was predicted to result in more areas of denudation and larger areas exposed to low wall shear stress. We conclude that the acute arterial injury, observed immediately following stent expansion, is caused by high circumferential hoop stresses in the interstrut region, and denuded area profiles are dependent on unit cell geometric features. Such findings when coupled with where drugs move might explain the drug–device interactions.