Viktor Dr. Szabó

Dr. Viktor Dr. Szabó

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2024 in Journal of Dentistry
Verified
Journal Article
Open access
VSViktor Dr. Szabó
Viktor Dr. Szabó
BSBence Tamás Szabó
Bence Tamás Szabó
KOKaan Orhan
Kaan Orhan
DVDániel Sándor Veres
Dániel Sándor Veres
DMDavid Manulis
David Manulis
ASAlex Sanders
Alex Sanders
This study aimed to assess the reliability of AI-based Diagnocat system that assists the healthcare processes in the diagnosis of caries on intraoral radiographs. The proximal surfaces of the 323 selected teeth on the intraoral radiographs were evaluated by two independent observers using the AI-based Diagnocat system. The presence or absence of carious lesions was recorded during Phase 1. After 4 months, the AI-aided human observers evaluated the same radiographs (Phase 2), and the advanced convolutional neural network (CNN) reassessed the radiographic data (Phase 3). Subsequently, data reflecting human disagreements were excluded (Phase 4). For each phase, the Cohen and Fleiss kappa values, as well as the sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy ​​of Diagnocat, were calculated. During the four phases, the range of Cohen kappa values between the human observers and Diagnocat were κ=0.66-1, κ=0.58-0.7, and κ=0.49-0.7. The Fleiss kappa values were κ=0.57-0.8. The sensitivity, specificity and diagnostic accuracy values ranged between 0.51-0.76, 0.88-0.97 and 0.76-0.86, respectively. The Diagnocat CNN supports the evaluation of intraoral radiographs for caries diagnosis, as determined by consensus between human and AI system observers. Our study may aid in the understanding of deep learning-based systems developed for dental imaging modalities for dentists and contribute to expanding the body of results in the field of AI-supported dental radiology, as concluded by other scientific publications.

19 February 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
VSViktor Dr. Szabó
Viktor Dr. Szabó
KOKaan Orhan
Kaan Orhan
Csaba Dobo-NagyCsaba Dobo-Nagy
Csaba Dobo-Nagy
DVDániel Sándor Veres
Dániel Sándor Veres
DMDavid Manulis
David Manulis
BSBence Tamás Szabó
Bence Tamás Szabó
Background/Objectives: Our study aimed to determine the accuracy of the artificial intelligence-based Diagnocat system (DC) in detecting periapical lesions (PL) on panoramic radiographs (PRs). Methods: 616 teeth were selected from 357 panoramic radiographs, including 308 teeth with clearly visible periapical radiolucency and 308 without any periapical lesion. Three groups were generated: teeth with radiographic signs of caries (Group 1), teeth with coronal restoration (Group 2), and teeth with root canal filling (Group 3). The PRs were uploaded to the Diagnocat system for evaluation. The performance of the convolutional neural network in detecting PLs was assessed by its sensitivity, specificity, and positive and negative predictive values, as well as the diagnostic accuracy value. We investigated the possible effect of the palatoglossal air space (PGAS) on the evaluation of the AI tool. Results: DC identified periapical lesions in 240 (77.9%) cases out of the 308 teeth with PL and detected no PL in 68 (22.1%) teeth with PL. The AI-based system detected no PL in any of the groups without PL. The overall sensitivity, specificity, and diagnostic accuracy of DC were 0.78, 1.00, and 0.89, respectively. Considering these parameters for each group, Group 2 showed the highest values at 0.84, 1.00, and 0.95, respectively. Fisher’s Exact test showed that PGAS does not significantly affect (p = 1) the detection of PL in the upper teeth. The AI-based system showed lower probability values for detecting PL in the case of central incisors, wisdom teeth, and canines. The sensitivity and diagnostic accuracy of DC for detecting PL on canines showed lower values at 0.27 and 0.64, respectively. Conclusions: The CNN-based Diagnocat system can support the diagnosis of PL on PRs and serves as a decision-support tool during radiographic assessments.