Saad Odeh

Dr. Saad Odeh

Western Sydney University, Sydney, New South Wales, Australia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
SOSaad Odeh
Saad Odeh
To improve the energy efficiency of dwellings, rooftop photovoltaic (PV) technology is proposed in contemporary designs; however, adopting this technology will add a new component to the roof that may affect its thermal balance. This paper studies the effect of roof shading developed by solar PV panels on dwellings’ thermal performance. The analysis in this work is performed by using two types of software packages: “AccuRate Sustainability” for rating the energy efficiency of a residential building design, and “PVSYST” for the solar PV power system design. AccuRate Sustainability is used to calculate the annual heating and cooling load, and PVSYST is used to evaluate the power production from the rooftop PV system. The analysis correlates the electrical energy generated from the PV panels to the change in the heating and cooling load due to roof shading. Different roof orientations, roof inclinations, and roof insulation, as well as PV dwelling floor areas, are considered in this study. The analysis shows that the drop in energy efficiency due to the shaded area of the roof by PV panels is very small compared to the energy generated by these panels. The analysis also shows that, with an increasing number of floors in the dwelling, the effect of shading by PV panels on thermal performance becomes negligible. The results show that insensitivity of the annual heating and cooling load to the thermal resistance of rooftop solar systems is only because the total thermal resistance is dominated by roof insulation.

14 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
SOSaad Odeh
Saad Odeh
TNTri Hieu Nguyen
Tri Hieu Nguyen
The installation of rooftop PV systems in residential buildings and dwellings has increased rapidly in the past decade, and these systems have become a major source of renewable energy in many countries. This paper presents a new method of estimating the potential of rooftop PV systems to meet energy demands in residential districts by introducing a roof suitability factor. The method of assessment is based on an online tool called SunSPot, which uses a solar radiation heat map layer of building roofs and the PVSYST solar performance software. A sample of 400 houses from four suburbs considered in the Sydney City Council 2030 sustainability plan was selected to conduct the performance analysis of rooftop PV systems and develop a formula that can estimate the suburban annual energy production. The results show that if the dwelling roofs in residential suburbs could be covered by PV arrays it would produce enough electricity to exceed the local electricity demand and, in some suburbs, a surplus of more than 87%.

8 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
Ibrahim Mohammed KhoswanIbrahim Mohammed Khoswan
Ibrahim Mohammed Khoswan
AAAbdelrahim Abusafa
Abdelrahim Abusafa
SOSaad Odeh
Saad Odeh
The connection between surface tension and viscosity has been the subject of several pieces of research on nanofluids. Researchers have discovered differing relationships between these two suspension qualities in the literature. Surface tension and viscosity have been found to be correlated in certain research works but not in other. The behavior of these fluids may be influenced by several factors, including temperature, the presence of surfactants, and the functional groups on carbon nanotubes (CNTs). This study investigates the relationship between surface tension and viscosity in CNT-Nanofluids by reviewing earlier research on the impact of CNT addition on water’s intermolecular interactions. The findings show that depending on different aspects of the nanofluids, the connection is complicated and uncertain. The study shows that although temperature and the addition of carbon nanotubes affect both surface tension and viscosity, other studies only consider how these factors affect one of these qualities. We conclude that under certain heat transfer circumstances, there is no clear-cut relationship between surface tension and viscosity in CNT–water fluids.

6 November 2019 in Australian Journal of Mechanical Engineering
Verified
Journal Article
Closed access
SOSaad Odeh
Saad Odeh
IIImad Ibrik
Imad Ibrik
The application of the standalone PV power system is currently considered as an alternative source of electricity for remote areas. The energy authority and An-Najah National University in the Palestinian territories worked on electrification of many small communities and villages by using centralised and decentralised solar PV systems. In this paper, long-term performance assessment of two 4.8 kW standalone PV pilot systems at two different villages is depicted. The unused energy of the storage battery, which is equal to 50% of the PV array output, is found to be the key factor of having low-performance ratio in the range of 0.25–0.65. The simulation results using PVSYST software illustrate that adopting the two-axis solar tracking mode for standalone PV systems has a significant impact on its output. It can reduce the size of the PV array by up to 50%. It is proposed to connect groups of villages with a local micro grid which can be fed by the surplus energy from the different standalone systems. Cost analysis of the current and the proposed design shows that the payback period of the micro-grid with two-axis tracking PV array is less than half of the period of the current standalone system. Abbreviations: Eoutput: Monthly array energy output (kWh); Earray: Capacity of the PV array (kW); Eload: Monthly energy demand of the site (kWh); Eunused: Unused energy when the battery is full (kWh); Esurplus: Percenatge of surplus energy (%); Epv: PV panel capacity (kW/m2); ηpv: PV panel efficiency (%); Irr: Global irradiation on horizontal surface (kWh/m2).

22 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
SOSaad Odeh
Saad Odeh
JFJunxi Feng
Junxi Feng
The application of residential rooftop PV systems increased significantly in the last 10 years in many countries and became a major source of clean energy in dwellings besides traditional solar hot water technology. To optimise the performance of these green energy systems, the incorporation of PV/thermal hybrid systems is a future option for sustainable residential building designs. In this work, a novel design of PV/Thermal (PVT) hybrid panels, using heat pipe technology, is proposed with the aim of fulfilling the hot water and electricity demand of a house in Sydney. The heat pipe system is integrated into a traditional PV panel to transfer the heat stored within the PV panel material to a header that is connected to the household hot water cycle. A preliminary analysis of the test results for the proposed PVT system design under different weather conditions in Sydney is conducted, where the transient variation of the output water temperature as well as power production is investigated. The results show that the hot water temperature at the header outlet reaches around a maximum of 50 °C on a typical summer day and a minimum of 30 °C on a typical winter day. The daily heat delivered to the hot water tank is found to be in the range of 3.7–5.2 MJ per m2 of the PVT panel surface area. The results show that the energy efficiency of the adopted PVT panel design could reach more than 4 times higher than the traditional PV panel.

30 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
SOSaad Odeh
Saad Odeh
LPLuke Pearling
Luke Pearling
Rooftop photovoltaic (PV) panel systems have become a key component in green building design, driven by new building sustainability measures advocated worldwide. The shading generated by the rooftop PV panel arrays can impact their annual heating and cooling load, as well as their overall thermal performance. This paper presents a long-term experimental investigation into the changes in roof temperature caused by PV panels. The experiment was conducted over the course of a year, with measurements taken on four sample days each month. The study is based on measurements of the covered roof temperature, the uncovered roof temperature, PV surface temperature, ambient air temperature, as well as solar irradiation, wind speed, and rainfall. The results reveal that the annual energy savings (MJ/m2) in the cooling load due to the covered roof are about 26% higher than the energy loss from the heating load due to shading. The study shows that the effect of the rooftop PV panels on the house’s total heating and cooling load savings is between 5.3 to 6.1%. This difference is significant in thermal performance analyses, especially if most of the roof is covered by PV panels.