As of today, bacteriological identification and the molecular approach PCR are considered the gold standards for Salmonella spp. detection. However, these methods are time-consuming and costly due to the requirements for enrichment and nucleic acid extraction. In this study, we evaluated the reliability of a developed colorimetric loop-mediated isothermal amplification (cLAMP) assay targeting the hilA gene, using Phenol Red as an amplification indicator. Given that Phenol Red is pH-dependent, and to develop an extraction-free test, we evaluated chicken meat pretreatment and thermal treatment. First, we assessed the reliability of this test using a pure culture of Salmonella spp. and then in 50 chicken samples pretreated with optimal NaOH concentrations under standardized conditions. Samples representing extreme pH values were artificially contaminated and subjected to DNA extraction and a heat-treatment protocol. Serial dilutions of these products served as templates for LAMP reactions. The assay sensitivity was estimated to be around 3.9 CFU/µL of pure bacterial culture. In contrast, in biological samples, we detected up to 10 CFU/µL using DNA extraction, while heat treatment successfully amplified the initial solution and even some dilutions up to 103 CFU/µL. In conclusion, our cLAMP assay demonstrated good sensitivity and provided clear evidence of its potential for in-field use without relying on prior enrichment steps and DNA extraction.
Salmonella enterica serovar Gallinarum is a non-motile serovar and is the causative agent of fowl typhoid, and poses a major challenge to poultry production, particularly where rapid diagnostics are lacking. Existing methods are either time-consuming or fail to distinguish motile from non-motile serotypes. We developed a dual-target colorimetric LAMP that detects Salmonella spp. via invA and discriminates S. Gallinarum via TRX (a taxon-restricted sequence), using two separate singleplex reactions. Specificity testing confirmed 100% accuracy, with exclusive amplification of S. Gallinarum through TRX. Analytical sensitivity was comparable to real-time PCR, detecting down to 2.41 CFU/µL (invA) and 1.65 CFU/µL (TRX). Applied to cloacal swabs from experimentally infected chickens (n = 12), the assay consistently outperformed bacteriological culture, detecting up to 25% more positives during early infection when bacterial loads were low or cells were non-culturable. This dual-target LAMP provides a rapid, sensitive, and serovar-discriminating diagnostic tool with strong potential for point-of-care use and real-time surveillance in poultry farms, thereby improving sanitary control of fowl typhoid and reducing associated economic losses.