Louise Terry

Dr. Louise Terry

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LTLouise Terry
Louise Terry
NCNicola Cassels
Nicola Cassels
KLKelly Lu
Kelly Lu
JAJennifer Acton
Jennifer Acton
TMTom H Margrain
Tom H Margrain
AWAshley Wood
Ashley Wood
Retinal and intra-retinal layer thicknesses are routinely generated from optical coherence tomography (OCT) images, but on-board software capabilities and image scaling assumptions are not consistent across devices. This study evaluates the device-independent Iowa Reference Algorithms (Iowa Institute for Biomedical Imaging) for automated intra-retinal layer segmentation and image scaling for three OCT systems. Healthy participants (n = 25) underwent macular volume scans using a Cirrus HD-OCT (Zeiss), 3D-OCT 1000 (Topcon), and a non-commercial long-wavelength (1040nm) OCT on two occasions. Mean thickness of 10 intra-retinal layers was measured in three ETDRS subfields (fovea, inner ring and outer ring) using the Iowa Reference Algorithms. Where available, total retinal thicknesses were measured using on-board software. Measured axial eye length (AEL)-dependent scaling was used throughout, with a comparison made to the system-specific fixed-AEL scaling. Inter-session repeatability and agreement between OCT systems and segmentation methods was assessed. Inter-session coefficient of repeatability (CoR) for the foveal subfield total retinal thickness was 3.43μm, 4.76μm, and 5.98μm for the Zeiss, Topcon, and long-wavelength images respectively. For the commercial software, CoR was 4.63μm (Zeiss) and 7.63μm (Topcon). The Iowa Reference Algorithms demonstrated higher repeatability than the on-board software and, in addition, reliably segmented all 10 intra-retinal layers. With fixed-AEL scaling, the algorithm produced significantly different thickness values for the three OCT devices (P<0.05), with these discrepancies generally characterized by an overall offset (bias) and correlations with axial eye length for the foveal subfield and outer ring (P<0.05). This correlation was reduced to an insignificant level in all cases when AEL-dependent scaling was used. Overall, the Iowa Reference Algorithms are viable for clinical and research use in healthy eyes imaged with these devices, however ocular biometry is required for accurate quantification of OCT images.

12 January 2022 in Human Molecular Genetics
Verified
Journal Article
Open access
PDF file
JGJeremy Guggenheim
Jeremy Guggenheim
RCRosie Clark
Rosie Clark
JCJiangtian Cui
Jiangtian Cui
LTLouise Terry
Louise Terry
KPKarina Patasova
Karina Patasova
UCUK Biobank Eye Vision Consortium
UK Biobank Eye Vision Consortium
Refractive errors are associated with a range of pathological conditions, such as myopic maculopathy and glaucoma, and are highly heritable. Studies of missense and putative loss of function (pLOF) variants identified via whole exome sequencing (WES) offer the prospect of directly implicating potentially causative disease genes. We performed a genome-wide association study for refractive error in 51 624 unrelated adults, of European ancestry, aged 40–69 years from the UK and genotyped using WES. After testing 29 179 pLOF and 495 263 missense variants, 1 pLOF and 18 missense variants in 14 distinct genomic regions were taken forward for fine-mapping analysis. This yielded 19 putative causal variants of which 18 had a posterior inclusion probability >0.5. Of the 19 putative causal variants, 12 were novel discoveries. Specific variants were associated with a more myopic refractive error, while others were associated with a more hyperopic refractive error. Association with age of onset of spectacle wear (AOSW) was examined in an independent validation sample (38 100 early AOSW cases and 74 243 controls). Of 11 novel variants that could be tested, 8 (73%) showed evidence of association with AOSW status. This work identified COL4A4 and ATM as novel candidate genes associated with refractive error. In addition, novel putative causal variants were identified in the genes RASGEF1, ARMS2, BMP4, SIX6, GSDMA, GNGT2, ZNF652 and CRX. Despite these successes, the study also highlighted the limitations of community-based WES studies compared with high myopia case–control WES studies.

27 November 2024 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
JGJeremy Guggenheim
Jeremy Guggenheim
LTLouise Terry
Louise Terry

1 July 2016
Verified
Book Chapter
Closed access
PDF file
Jingjing DengJingjing Deng
Jingjing Deng
Xianghua XieXianghua Xie
Xianghua Xie
LTLouise Terry
Louise Terry
AWAshley Wood
Ashley Wood
NWNick White
Nick White
RNRachel V. North
Rachel V. North

1 June 2020 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
HDHarshali Dhirajlal
Harshali Dhirajlal
MVMarta Vianya-Estopa
Marta Vianya-Estopa
MNManbir Nagra
Manbir Nagra
LMLouise Madden
Louise Madden
CMCarole Maldonado-Codina
Carole Maldonado-Codina

1 October 2020 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
MVMarta Vianya-Estopa
Marta Vianya-Estopa
MNManbir Nagra
Manbir Nagra
ACArnold Cochrane
Arnold Cochrane
NRNeil Retallic
Neil Retallic
DDDean Dunning
Dean Dunning
MJMahesh Joshi
Mahesh Joshi